| Précision | ±7% |
| Agricultural Greenhouses — Automatic Weather Station s | Urban Lighting |
| Analog Output Is Zero | Check the power supply, signal wiring and analog input configuration. |
| Avoid Unwanted Shadows | Keep nearby brackets, poles and structures from shading the sensing surface when measuring ambient daylight. |
| Black / Green | Power - |
| Black Wire | Ground (GND) |
| Blue | RS485 B- / RX |
| Blue Wire | RS-485 A |
| Câble | Do not arbitrarily modify the factory cable or soldered components; specify the required cable length before ordering. |
| Calibration method | Two-point calibration |
| Cleaning method | Built-in self-cleaning brush |
| Current Output Load | RL ≤ 300 Ω |
| Data Scaling | Decoded raw value ÷ 10 = Illuminance in Lux |
| Default Baud Rate | 9600 bps |
| Device Address | 0–255 configurable |
| Do Not Disassemble | The sensor is a precision device and should not be opened during normal installation. |
| Fixed Mounting | Use M4 screws and nuts through the two mounting holes to secure the sensor to a suitable bracket. |
| Matériau du boîtier | 316L stainless steel |
| Illuminance — Visible light falling on a surface | Lux |
| Mode d'installation | Submersible installation, 3/4NPT |
| Livestock Facilities — Laboratories | Industrial Monitoring |
| Measured Parameter | Illuminance |
| Measurement Location | Install at the point where the actual light condition needs to be measured. |
| Measurement Principle | Fluorescence method |
| Plage de mesure | 0–200,000 Lux |
| Measurement Unit | Lux |
| Measurement — What It Represents | Typical Unit |
| Minimum Communication Interval | 1000 ms |
| Minimum Detection Limit | 1 Kcells/mL |
| Modbus Integration | RS485 version can connect to PLCs, RTU s, weather-station loggers and IoT gateways. |
| Modèle | NBL-WQ-BGA-408-S |
| Multiple outputs | RS485, 4–20 mA and 0–5 V versions support different data-acquisition systems. |
| NBL-W-LUX Illuminance Sensor — Illuminance in Lux | Lighting control, greenhouse environmental monitoring, buildings and urban lighting |
| NBL-W-PARS PAR Sensor — Photosynthetically active radiation / plant-light measurement | Plant research, greenhouses and controlled-environment agriculture |
| No RS485 Response | Check A/B wiring, baud rate, device address and communication settings. |
| Humidité de fonctionnement | 0–80%RH |
| Température de fonctionnement | -10 to 70°C |
| Sortie | Formula |
| Output Method | RS-485 (Modbus/ RTU ), 4-20mA (optional) |
| Output Options | RS485 / 4–20 mA / 0–5 V |
| Output — Typical Connection | Recommended Use |
| PAR / PPFD — Plant-relevant photon radiation within approximately 400–700 nm | μmol·m⁻²·s⁻¹ |
| Parité | None |
| Consommation | 0.2W@12V |
| Alimentation | DC 12 V / DC 24 V; other configurations available |
| Power Supply Voltage | 12~24V DC |
| Problem / Check | Recommended Action |
| Nom du produit | Illuminance / Light Intensity Sensor |
| Poids du produit | Approx. 170 g |
| Produits | Weather Stations |
| Indice de protection | IP68 |
| Protocole | Modbus RTU |
| Pyranometer — Broadband solar irradiance in W/m² | Weather stations, solar energy and surface-energy studies |
| Read Function | Function Code 03 |
| Reading Too High or Low | Check the light-sensing cover for oil, dust or other contamination and clean it carefully. |
| RED | Power + |
| Red Wire | Power positive (12~24VDC) |
| Résolution | 0.1 Kcells/mL |
| Response Time (T90) | <30s |
| RS485 Modbus — PLC, RTU , weather station, IoT gateway | Digital monitoring and multi-sensor networks |
| Sensor — Main Measurement | Typical Application |
| Silicon Blue Detector | Uses a high-sensitivity photovoltaic detector for light-intensity measurement. |
| Smart Buildings — Environmental Monitoring | Lighting Control |
| Solar Irradiance — Radiant solar power received per unit area | W/m² |
| Standard Cable Length | 2.5 m, customizable |
| Bits d'arrêt | 1 or 2 |
| Température de stockage | -5~65℃ |
| Temperature Compensation | Automatic temperature compensation (Pt1000) |
| Unstable Reading | Check whether moving shadows, reflected light or an unstable power supply are affecting the measurement. |
| Voltage Output Load | RL ≥ 1 kΩ |
| Wavelength Range | 380–730 nm |
| White wire | RS-485 B |
| Conditions d'utilisation | 0~50℃, <0.2 MPa |
| Yellow | RS485 A+ / TX |
| Yellow wire | Current output (4-20mA, leave floating when not in use) |