| Précision Humidité | ±2.0 % RH |
| Précision pression | ±0.1 hPa |
| Bande de fréquence | 863-930MHz |
| Plage de pression | 260-1260 hPa |
| Plage d'humidité | 0 to 100% |
| Barometer | Sensor Type: 0x73; Data Length: 2; Ratio: 0.1; Scope: 260 ~ 1260; Unit: hPa |
| Battery Cell | Commonly known as a battery. It is the fundamental unit of energy storage, which converts chemical energy to electrical energy. |
| Battery Cell Model | Technical Specifications: Rechargeable cylindrical lithium-ion battery H18650CH; Remark: H18650CH or similar products |
| Battery Model | Technical Specifications: RAK9154 |
| Battery Module | The intermediate energy storage unit comprises several individual cells, circuitry components, and electrical and communication interfaces. |
| Battery Pack | A comprehensive power system consisting of multiple battery modules and circuits working together to supply power to electrical devices. |
| BMS | Battery Management System |
| BMU | Battery Management Unit |
| BOL | Begin of Life |
| Bus-bar | Battery Pole Connecting Rod |
| Capacité | The amount of electrical charge that a fully charged battery can store and subsequently provide to a device or system.; Unit: Ampere-hours (Ah) |
| CMC | Cell Manager Circuit |
| Connectivité | NB-IoT |
| Energy Capacity | The total amount of energy that a fully charged battery can deliver under specific conditions.; Unit: Watt-hours (Wh) or kilowatt-hours (kWh) |
| EOL | End of Life |
| Gateway Load | Connector Socket Model: SP1110/P4; Connector Plug Model: SP1110/P4-N; Definition: Pin1: P+; Remark: SP11; IP67; Rated current 2 A; Contact diameter 0.75 mm * 4; Remark: Pin2: P-; Remark: Pin3: R485A; Remark: Pin4: RS485B |
| Humidité | Sensor Type: 0x68; Data Length: 1; Ratio: 1; Scope: 0 ~ 100; Unit: %RH |
| Humidity Resolution | 0.01 %RH |
| Humidity Sensor Precision | ±2.0 %RH |
| HV | High Voltage |
| Interface | I2C |
| LV | Low Voltage |
| Maximum Charging Continuous Current | Technical Specifications: 0.2 C (1.0 A); Remark: Limited by solar charger |
| Maximum Discharge Continuous Current | Technical Specifications: 0.4 C (2.0 A) |
| Maximum PV Input Voltage | Technical Specifications: 30 V; Remark: Open circuit voltage |
| Measuring Current (low power mode) | 270 uA |
| Measuring Current (normal mode) | 430 uA |
| Dimensions du module | 10 x 10 mm |
| OCV | Open Circuit Voltage |
| Humidité de fonctionnement | Technical Specifications: 20 %RH ~80 %RH |
| Température de fonctionnement | Technical Specifications: Charging temperature:; 0° C ~45° C; Discharge temperature:; -20° C ~60° C |
| Plage de tension de fonctionnement | Technical Specifications: 9 V ~12.6 V |
| Pressure Output Data Rate | 1/10/25/50/75 Hz |
| Pressure Precision | ± 0.1 hPa |
| Pressure Sensitivity | 4096 LSB/hPa |
| PV Input | Technical Specifications: 18 V/1.0 A; Remark: Typical |
| RAK1901 Humidity Sensor Data Unit | ID (channel): 1 Byte; Type: 1 Byte; Data: 1 Byte |
| RAK1901 Temperature Sensor Data Unit | ID (channel): 1 Byte; Type: 1 Byte; Data: 2 Bytes |
| RAK1902 Pressure Sensor Data Unit | ID (channel): 1 Byte; Type: 1 Byte; Data: 2 Bytes |
| RAK1902 Temperature Sensor Data Unit | ID (channel): 1 Byte; Type: 1 Byte; Data: 2 Bytes |
| Rated Capacity | At the beginning of life (BOL), the minimum capacity that a fully charged battery can provide at a discharge rate of 1 C (discharge C-rate). |
| Puissance nominale | Technical Specifications: 56.16 Wh |
| Tension nominale | Refers to the approximate voltage value that a battery is designed to operate at or provide. |
| RMS Pressure Sensing Noise | 0.0075 hPa RMS |
| Sensor Hub Load | Connector Socket Model: SP1110/P5; Connector Plug Model: SP1110/P5-N; Definition: Pin1: P+; Remark: SP11; IP67; Rated current 2 A; Contact diameter 0.75 mm * 5; Remark: Pin2: P-; Remark: Pin3: TXD; Remark: Pin4: 3V3_In; Remark: Pin5: RXD |
| Shutdown Current | 1 uA |
| Taille | Technical Specifications: Length: 180 (±3) mm; Width: 130 (±3) mm; Height: 60 (±3) mm |
| Sleep current | 0.3 uA |
| SOC | State of charge |
| SOC Transportation Range | Technical Specifications: 0.5 |
| Température de stockage | Technical Specifications: -20° C ~60° C; Remark: More than three months at 25° C |
| Température | Value: -30° C to 50° C, 40% SOC; Remark: Storage time < 3 months; Value: 0° C to 25° C, 40% SOC; Remark: Storage time > 3 months |
| Précision en température | ±0.2 °C |
| Temperature Output Data Rate | 1/10/25/50/75 Hz |
| Temperature Precision | ±1.5° C |
| Temperature_RAK1901 | Sensor Type: 0x67; Data Length: 2; Ratio: 0.1; Scope: -40 ~ +125; Unit: ° C |
| Temperature_RAK1902 | Sensor Type: 0x67; Data Length: 2; Ratio: 0.1; Scope: -40 ~ +85; Unit: ° C |
| Plage de température | -40 to +125 °C |
| Temperature Resolution | 0.01° C |
| Temperature Sensor Precision | ±2.0° C |
| Unit | V : Volt, voltage; A : Ampere, current; Ah : Ampere-hour, electric charge; Wh : Watt-hour, electrical energy; Ω : Ohm, resistance; ° C : Celsius, temperature; mm : millimeter, length; s : second, time; kg : kilogram, weight; Hz : Hertz, frequency |
| VDD (module power supply) | 3.3 V |
| Tension | Technical Specifications: ≤20 mV; Remark: SOC 30%~60%; rest for at least 2 hours after charging or discharging |
| Poids | Technical Specifications: 0.85 kg |
| Technologies sans fil | LoRa, NB-IoT |