| ACL and QoS | Standard IP ACLs (hardware ACLs based on IP addresses) |
| Acoustic noise | 27°C (80.6°F): 40 dB; Maximum value: < 78 dB |
| Altitude | Operating altitude: –500 m to +5,000 m (–1640.42 ft. to +16,404.20 ft.); Storage altitude: –500 m to +5,000 m (–1640.42 ft. to +16,404.20 ft.) |
| BootROM | 16 MB (storing boot software for 1+1 boot redundancy) |
| Cable hot swapping | Supported |
| CPU | Single-core CPU, with the clock speed of 1.2 GHz |
| Device virtualization | VSU |
| EMC regulation | EN 300386, EN 55032 Class A, EN 55035, EN IEC 61000-3-2, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 |
| ESD | ESD contact/air discharge: 6 kV/8 kV; ESD susceptibility contact/air discharge: 8 kV/15 kV |
| Ethernet switching | Jumbo frame (maximum length: 9,216 bytes) |
| Fan | 2 x fixed fan modules |
| Fan Module | Not Supported |
| Fan monitoring | Automatic speed adjustment; Fan failure alarming |
| Fan redundancy | Not supported |
| Fixed management port | 1 x RJ45 console port; 1 x RJ45 MGMT port |
| Fixed service port | 24 x 100/1000/2.5G/5GBASE-T ports, supporting PoE/PoE+/PoE++; 4 x 10GE/25GE SFP28 ports |
| Flash memory | 1 GB (storing boot software for 1+1 boot redundancy) |
| GE-SFP-LH40-SM1310-BIDI | 1000BASE-LH, SFP transceiver, TX1310/RX1550, BiDi LC, 40 km over SMF |
| GE-SFP-LH40-SM1550-BIDI | 1000BASE-LH, SFP transceiver, TX1550/RX1310, BiDi LC, 40 km over SMF |
| GE-SFP-LX03-SM1310-BIDI-I | 1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 3 km over SMF |
| GE-SFP-LX03-SM1550-BIDI-I | 1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 3 km over SMF |
| GE-SFP-LX20-SM1310-BIDI | 1000BASE-LX, SFP transceiver, TX1310/RX1550, BiDi LC, 20 km over SMF |
| GE-SFP-LX20-SM1550-BIDI | 1000BASE-LX, SFP transceiver, TX1550/RX1310, BiDi LC, 20 km over SMF |
| Heat dissipation | Fan cooling, left-to-right and front-to-right airflow |
| Humidité | Operating humidity: 10% to 90% RH (non-condensing); Storage humidity: 5% to 95% RH (non-condensing) |
| IP Routing | Static routing |
| IP service | Static and dynamic ARP |
| Maximum number of ACEs | In: 2,500 Out: 1,000 |
| Maximum number of ARP address entries | 160,000 |
| Maximum number of IGMP groups | 4,000 |
| Maximum number of IPv4 multicast routes | 4,000 |
| Maximum number of IPv4 unicast routes | 16,000 (shared with IPv6 routes) |
| Maximum number of IPv6 multicast routes | 2,000 |
| Maximum number of IPv6 unicast routes | 8,000 (shared with IPv4 routes) |
| Maximum number of MAC address entries | 32,768 |
| Maximum number of MLD groups | 2,000 |
| Maximum number of ND entries | 4,000 |
| Maximum number of SVIs | 1,000 |
| Puissance de sortie maximale | Fixed power supply: 460 W |
| Maximum power consumption | 90 W (without PoE); 460 W (full PoE load) |
| Mean Time Between Failure (MTBF) | 194,296 hours (about 22 years) |
| Mémoire | 1 GB DDR4 (32-bit width, 4-bit ECC) |
| Mini-GBIC-GT | 1000BASE-X to 1000BASE-T, copper SFP transceiver, RJ45, 100 m over Cat 5e/6/6a; The port needs to be configured with auto-negotiation |
| MINI-GBIC-LH40-SM1310 | 1000BASE-LH, SFP transceiver, 1310 nm, Duplex LC, 40 km over SMF |
| MINI-GBIC-LX-SM1310 | 1000BASE-LX, SFP transceiver, 1310 nm, Duplex LC, 10 km over SMF |
| MINI-GBIC-SX-MM850 | 1000BASE-SX, SFP transceiver, 850 nm, Duplex LC, 500 m over MMF |
| MINI-GBIC-ZX80-SM1550 | 1000BASE-ZX, SFP transceiver, 1550 nm, Duplex LC, 80 km over SMF |
| Module slot | Not Supported |
| Multidiffusion | IGMPv1/v2/v3 and IGMP proxy |
| NMS and maintenance | SPAN, RSPAN, and ERSPAN |
| Performance and Capacity | RG-S6100 Series |
| PoE output power | Each PoE port provides up to 90 W of power.; The maximum power is 370 W.; Note: The maximum number of powered devices supported by the switch is determined by the available power of the switch and the actual power consumption of each device. |
| PoE port | Ports 1 to 24 support PoE/PoE+/PoE++ (IEEE802.3af/at/bt) power supply |
| PoE power cable pairs | Four pairs (1-2, 3-6, 4-5, and 7-8 pairs) |
| Entrée d'alimentation | AC input:; ● Rated input voltage: 100 V AC to 240 V AC, 50/60 Hz; ● Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz; ● Maximum input current: 6 A |
| Power Module | Not Supported |
| Power module hot swapping | Supported |
| Power module redundancy | Not supported |
| Alimentation | 1 x fixed power supply |
| Power supply and consumption | RG-S6110-24MG4VS-UP |
| Power supply monitoring | Not supported |
| Rack height | 1 RU |
| Real-time Clock (RTC) | Supported |
| Reliability | REUP |
| RG-PA1000I-P-F | 1000 W AC power module |
| RG-PA600I-P-F | 600 W AC power module |
| RG-S6110-24MG4VS-UP | 24 x 100/1000/2.5G/5GBASE-T ports, 4 x 10GE/25GE SFP28 ports |
| RG-S6110-48MG4VS2QXS-UP | 48 x 100/1000/2.5G/5GBASE-T ports, 4 x 10GE/25GE SFP28 ports, 2 x 40GE QSFP+ ports |
| RG-S6120-24XMG4XS4VS-UP-H | 24 x 100/1000/2.5G/5G/10GBASE-T ports, supporting PoE/PoE+/PoE++, 4 x 1GE/10GE SFP+ ports, 4 x 10GE/25GE SFP28 ports |
| RG-S6120-48XMG4VS2QXS-UP-H | 48 x 100/1000/2.5G/5G/10GBASE-T ports, 4 x 10GE/25GE SFP28 ports, 2 x 40GE QSFP+ ports |
| RoHS | European RoHS Directive 2011/65/EU & Amendment(EU) 2015/863 |
| Safety regulation | IEC 62368-1 |
| Sécurité | Multi-AAA |
| Protection contre les surtensions | MGMT port: 4 kV; Service port: 8 kV; Power port: common mode 6 kV, differential mode 6 kV |
| Switch buffer | 4 MB |
| System packet forwarding rate *1 | 392 Mpps |
| System switching capacity *2 | 528 Gbps |
| Température | Operating temperature: 0°C to 45°C (32°F to 113°F); Storage temperature: -40°C to +70°C (-40°F to +158°F); Note: At an altitude between 3,000 m (9,842.52 ft.) and 5,000 m (16,404.20 ft.), every time the altitude increases by 220 m (721.78 ft.), the maximum temperature decreases by 1°C (1.8°F). |
| Temperature Monitoring | Supported |
| Unit dimensions (W x D x H) | 442.0 mm x 220.0 mm x 43.6 mm (17.40 in. x 8.66 in. x 1.72 in.) |
| Unit Weight | 3.71 kg (8.18 lbs) |
| USB | 1 x USB 2.0 port |
| USB hot swapping | Supported |
| VG-SFP-AOC7M(M) | 25GBASE, SFP28 active optical cable (AOC), 7 m, including one cable and two optical transceivers |
| VG-SFP-SR-MM850 | 25GBASE-SR, SFP28 transceiver, 850 nm, Duplex LC, 100 m over OM4 MMF, 70 m over OM3 MMF |
| VSU bandwidth | S6110-24MG4VS-UP: 100 Gbps; S6110-48MG4VS2QXS-UP: 180 Gbps; S6120-24XMG4XS4VS-UP-H: 140 Gbps; S6120-48XMG4VS2QXS-UP-H: 200 Gbps |
| XG-SFP-AOC1M | 10GBASE, SFP+ active optical cable (AOC), 1 m, including one cable and two optical transceivers |
| XG-SFP-AOC3M | 10GBASE, SFP+ active optical cable (AOC), 3 m, including one cable and two optical transceivers |
| XG-SFP-AOC5M | 10GBASE, SFP+ active optical cable (AOC), 5 m, including one cable and two optical transceivers |
| XG-SFP-ER-SM1550 | 10GBASE-ER, SFP+ transceiver, 1550nm, Duplex LC, 40 km over SMF |
| XG-SFP-LR10-SM1270-BIDI-I | 10GBASE-LR, SFP+ transceiver, TX1270/RX1330, BiDi LC, 10 km over SMF |
| XG-SFP-LR10-SM1330-BIDI-I | 10GBASE-LR, SFP+ transceiver, TX1330/RX1270, BiDi LC, 10 km over SMF |
| XG-SFP-LR-SM1310 | 10GBASE-LR, SFP+ transceiver, 1310nm, Duplex LC, 10 km over SMF |
| XG-SFP-SR-MM850 | 10GBASE-SR, SFP+ transceiver, 850nm, Duplex LC, 300 m over MMF |
| XG-SFP-T | 10 Gigabit SFP+ optical to electrical transceiver, maximum transmission distance of 70m |