| Cable type — Twisted-pair | 100m(CAT5E, CAT6) |
| Electrical Specifications — Input voltage | DC 10-58V |
| Electrical Specifications — Power consumption | Normal model<6W; POE model<126W |
| EMC&Ingress protection — EMI | CLASS A |
| EMC&Ingress protection — ESD | IEC 61000-4-2 Level 4(8K/15K) |
| EMC&Ingress protection — Ethernet port surge protection | IEC 61000-4-5 Level 3(4KV/2KV)(10/700us) |
| EMC&Ingress protection — Free fall | 0.5m |
| EMC&Ingress protection — IP level | IP40 |
| EMC&Ingress protection — Power surge protection | IEC 61000-4-5 Level 3(4KV/2KV)(8/20us) |
| Environment — Operating temperature | -40℃~+85℃ |
| Environment — Relative humidity | 5%~95%,(non-condensing) |
| Environment — Storage temperature | -40℃~+85℃ |
| Hardware; Parameters — Certifications | CE/FCC/ROSH |
| Hardware; Parameters — Dimensions | 150*98.8*30 mm (L*W*H, including terminals and mounting ears) |
| Hardware; Parameters — Input Current | 67mA @12V |
| Hardware; Parameters — Input Voltage | DC 5.0~36.0V |
| Hardware; Parameters — Installation | Panel mounting |
| Hardware; Parameters — Operating Humidity | 5%~95% RH(non-condensing) |
| Hardware; Parameters — Operating; Temperature | -40~85℃ |
| Hardware Parameters — Storage humidity | 5%~95% RH(non-condensing) |
| Hardware; Parameters — Storage Temperature | -40~105℃ |
| Hardware; Protection — EFT-IEC61000-4-4; Level 3 | ±2KV |
| Hardware; Protection — ESD-IEC61000-4-2; Level 4 | Air±15KV, contact±8KV |
| Hardware; Protection — Surge-IEC61000-4-5; level 3 | ±2KV |
| Interface — Ethernet port number | 8*10/100M |
| Interface — LED indicators | PWR,Link/ACT |
| Interface — Network interface | 10/100 Base - T |
| Interface; Parameters — Data Bit | 7, 8 |
| Interface; Parameters — Ethernet Port Spec. | RJ45, 10/100Mbps, auto MDI/MDIX |
| Interface; Parameters — Flow Control | None, RTS/CTS (RS-232 only), XON/XOFF |
| Interface; Parameters — Parity | None, Even, Odd |
| Interface; Parameters — RS-485 Pull-up and; Pull-down Resistor | 2.2KΩ |
| Interface; Parameters — Serial Baud Rate | 600-230.4K(bps) |
| Interface; Parameters — Serial signals | RS232: RXD, TXD, GND, RTS, CTS; RS485:A+,B-,GND |
| Interface — Power interface | Phoenix terminal, redundant dual power supply |
| Mechanical structure — Installation method | DIN rail |
| Mechanical structure — Shell material | Aluminium alloy |
| Mechanical structure — Size | 143X104X48mm |
| Mechanical structure — Weight | 0.54kg |
| (MTBF) | 100000 hours |
| Network Topology — Bus topology | support |
| Network Topology — Star topology | support |
| Network Topology — Tree Topology | support |
| Parameters — Buffer | 512K |
| Parameters — Flow control | Support |
| Parameters — Forwarding delay | <4us |
| Parameters — Jumbo frame | 2048bytes |
| Parameters — MAC address table | 1K |
| Parameters — MDX/MIDX | Support |
| Parameters — Packet forwarding rate | 1.19Mpps |
| Parameters — Switching capacity | 1.6G |
| Software; Parameters — Ethernet Packets; Cache | 48Kbyte |
| Software; Parameters — HTTP Client | Support |
| Software parameters — IP mode | Static IP, DHCP |
| Software; Parameters — Modbus Gateway | Support |
| Software Parameters — Network Protocol | IP/TCP/UDP/ARP/ICMP/IPV4/DHCP/DNS |
| Software; Parameters — Serial Packets Cache | Dynamic packet cache. For example:; When the packet length is 10 byte, the serial port can cache; 450 packets(4.5KB). When the packet length is 1460 bytes, the serial port can; cache 10 packets(14.6KB). |
| Software; Parameters — UDP Broadcast | Support |
| Software parameters — User Configuring | Setup utility, webpage, AT commands |
| Software; Parameters — Websocket | Support |