IEC 60529: degrees of protection provided by enclosures (IP code)

The standard that defines the IP code: how well an enclosure protects against the intrusion of solid objects and dust (first digit) and against water (second digit), and the tests used to rate it.

Key points

First digit 0 to 6 for solids and dust; second digit 0 to 9 for water. An "X" means the characteristic was not rated.
A rating describes the enclosure under test conditions, not the mounted product with its cable glands and connectors; check the whole assembly.
IP69K comes from ISO 20653 (road vehicles), not from IEC 60529; IEC 60529 itself defines IPX9 for high-temperature, high-pressure jets.

Common ratings

IP65

Dust-tight; protected against water jets from any direction.

IP67

Dust-tight; protected against temporary immersion (up to 1 m for 30 minutes).

IP68

Dust-tight; protected against continuous immersion under conditions set by the manufacturer.

IPX9

Protected against close-range high-pressure, high-temperature jets.

This is a summary of scope and structure, not the standard itself. Always check the edition in force and ask the supplier for the declaration or test report for the exact part number.