TC-2200
Industrial Residual Chlorine and pH Transmitter with 4-20 mA Output

- Residual chlorine range
- 0-20.00mg/L
- Accuracy
- ±1% FS
- Dimensions
- 96*96*132mm
- Cut off dimensions
- 92X92mm
Industrial Residual Chlorine and pH Transmitter with 4-20 mA Output
The Apure TC-2200 is an online residual chlorine transmitter with pH and temperature measurement and a 4-20 mA analogue output for water process control.
Overview. The Apure TC-2200 is an online digital residual chlorine transmitter, supplied with pH and temperature measurement in the listed configuration. It is used as a measuring instrument within a system made up of the instrument, the chlorine probe and the sample-flow assembly.
Measuring range and accuracy. Residual chlorine range of 0 to 20.00 mg/L, pH of 0 to 14 and temperature of 0 to 99 °C with a resolution of 0.1 °C. Accuracy is ±1 % FS and stability ±1 % FS over 24 h. Automatic temperature compensation is provided, with NTC10K or PT1000 elements selectable in manual or automatic mode.
Display and settings. Large-screen liquid crystal display showing the residual chlorine value, temperature and output current simultaneously. Factory-setting recovery and slope correction functions are included, along with an adjustable hysteresis to avoid frequent relay switching.
Outputs and communication. One optically isolated 4-20 mA analogue output. RS485 communication is available as an option; its supported functions, register map and serial settings must be verified for the ordered version.
Power and reliability. Power supply AC 220 V ±10 %, 50/60 Hz. Dimensions 96 × 96 × 132 mm, panel cut-out 92 × 92 mm, sample pressure 0 to 0.5 MPa. A watchdog function supports continuous operation, and power-failure protection exceeds 10 years.
Implementation. Wetted components, including the probe and flow cell, must respect their own operating limits. Chlorine measurement should be verified against a reference method suited to the chlorine species required, and pH calibrated with the buffer family selected on the instrument.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for TC-2200, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Dimensions | 96*96*132mm |
| Accuracy | ±1% FS |
| Automatic temperature compensation | 0-99℃ |
| Cable Length | 5M |
| Cut off dimensions | 92X92mm |
| Measuring Range | Residual Chlorine: 0-20.00mg/L; pH: 0-14pH; Temp: 0-99℃ |
| Medium pressure: | 0~0.5MPa |
| Model | TC-2200 |
| Outline Dimension | 96*96*132mm(H*W*D) |
| Output signal | 1 set of 4-20mA signal |
| Panel cut-out | 92X92mm(H*W) |
| pH range (listed configuration) | 0-14pH |
| Power supply | AC 220V±10% 50/60 HZ |
| Residual chlorine range | 0-20.00mg/L |
| Stability | ±1%(FS)/24h |
| Temperature | 0~99℃(resolution ratio 0.1℃) |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for TC-2200. For a missing document or a specific revision, our experts send it to you.
The Apure TC-2200 is an online residual chlorine transmitter with pH and temperature measurement and a 4-20 mA analogue output for water process control.
| Parameter | Value |
|---|---|
| Dimensions | 96*96*132mm |
| Accuracy | ±1% FS |
| Automatic temperature compensation | 0-99℃ |
| Cable Length | 5M |
| Cut off dimensions | 92X92mm |
| Measuring Range | Residual Chlorine: 0-20.00mg/L; pH: 0-14pH; Temp: 0-99℃ |
| Medium pressure: | 0~0.5MPa |
| Model | TC-2200 |
| Outline Dimension | 96*96*132mm(H*W*D) |
| Output signal | 1 set of 4-20mA signal |
| Panel cut-out | 92X92mm(H*W) |
| pH range (listed configuration) | 0-14pH |
| Power supply | AC 220V±10% 50/60 HZ |
| Residual chlorine range | 0-20.00mg/L |
| Stability | ±1%(FS)/24h |
| Temperature | 0~99℃(resolution ratio 0.1℃) |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Industrial Residual Chlorine and pH Transmitter with 4-20 mA Output

PH installation accessories

MDA-PH pH ORP meter

MDA-U2-PH pH ORP meter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | TC-2200 |
| Manufacturer | Apure |
pH Sensors
Industrial soil monitoring station with RS485 interface
Price on request
pH Sensors
Industrial Online ORP Sensor with Platinum Bulb
Price on request
pH Sensors
Chemical-Resistant UHF RFID Hard Tag for Metal Surfaces
Price on request
pH Sensors
Analog Composite Glass pH Electrode · Ref. : ASP200
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details