BOQU AH-800 online analyzer that fully automatically measures total or carbonate water hardness and total alkalinity by titration, for water quality control and monitoring.
Power consumption25 VA (in operation), 3.5 VA (stand by)
Accuracy+/- 5%
Dimensions300x300x200 mm (WxHxD)
Environmental temp.5-45℃
Measurement methodTitration method
Measuring water temp.5-45℃
Product overview
Overview. The BOQU AH-800 is an online water hardness and alkali analyzer that fully automatically measures total or carbonate water hardness and total alkali by titration. It allows two different limit values to be defined and checks water quality by determining the absorption of the sample during reagent titration. It suits recognising hardness levels, quality control of water softening facilities and monitoring of water blending facilities.
Main characteristics. Measurement ranges of 0.5 to 534 ppm for hardness and 5.34 to 401 ppm for total alkali, with an accuracy of +/- 5% and a repeatability of ±2.5%. The analysis start is programmable by time intervals of 5 to 360 minutes, by external signal or by programmable volume intervals, and the flush time is programmable from 15 to 1800 seconds. The analyzer is self calibrating and self monitoring, and commissioning is supported by a configuration assistant.
Interfaces and connectivity. Four potential-free relay outputs, max. 250 Vac / Vdc and 4 A, one 0/4-20 mA output and a CAN interface.
Power and environment. Power supply of 90 to 260 Vac (47 to 63 Hz), power consumption of 25 VA in operation and 3.5 VA on standby. Protection grade IP65, environmental temperature of 5 to 45 ℃ and measuring water temperature of 5 to 45 ℃. Dimensions 300 x 300 x 200 mm (W x H x D). Water inlet pressure of ca. 0.5 to 5 bar maximum, 1 to 2 bar recommended. The water inlet must be clear, colourless, free of solid particles and without gas bubbles.
Typical uses. Industrial measurement of water hardness and alkali, for example in waste water treatment, environmental monitoring or drinking water.
Reagents. Several reagents cover distinct measuring ranges, from model TC5010 (5.34 to 134 ppm) to model TC5030 (16.0 to 401 ppm) for alkali, and models TH5001 to TH5100 for hardness.
BOQU AH-800 online analyzer that fully automatically measures total or carbonate water hardness and total alkalinity by titration, for water quality control and monitoring.
Power consumption25 VA (in operation), 3.5 VA (stand by)
Accuracy+/- 5%
Dimensions300x300x200 mm (WxHxD)
Environmental temp.5-45℃
Measurement methodTitration method
2. Datasheet extract (recorded values)
Parameter
Value
Dimensions
300x300x200 mm (WxHxD)
Accuracy
+/- 5%
Analysis start
- programmable time intervals (5 - 360 minutes) - external signal - programmable volume intervals
Environmental temp.
5-45℃
Flush time
programmable flush time (15 - 1800 seconds)
Measurement method
Titration method
Measurement Range
Hardness : 0.5-534ppm, total alkali:5.34~401ppm
Measuring water temp.
5-45℃
Output
- 4 x potential-free Relays (max. 250 Vac / Vdc; 4A(as potential free output NC/NO)) - 0/4-20mA - CAN interface
Power
90 - 260 Vac (47 - 63Hz)
Power consumption
25 VA (in operation), 3.5 VA (stand by)
Protection Grade
IP65
Reagent type — °dH — °F — ppm CaCO3
mmol/l
Reagents model
Measuring range
Repetition
±2.5%
TC5010
5.34~134 ppm
TC5015
8.01~205ppm
TC5020
10.7~267ppm
TC5030
16.0~401ppm
TH5001 — 0.03-0.3 — 0.053-0.534 — 0.534-5.340
0.005-0.053
TH5003 — 0.09-0.9 — 0.160-1.602 — 1.602-16.02
0.016-0.160
TH5010 — 0.3-3.0 — 0.534-5.340 — 5.340-53.40
0.053-0.535
TH5030 — 0.9-9.0 — 1.602-16.02 — 16.02-160.2
0.160-1.602
TH5050 — 1.5-15 — 2.67-26.7 — 26.7-267.0
0.267-2.670
TH5100 — 3.0-30 — 5.340-53.40 — 53.40-534.0
0.535-5.340
Water inlet in general
clear, colourless, free of solid particles, without gas bubbles
Water inlet pressure
ca. 0.5 - 5 bar (max.) (Recommended 1 - 2 bar)
Applications and use cases
Architectures in which AH-800 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details