5NTU
Flow-through laser turbidimeter for freshwater low turbidity

- Operating Temperature
- 0~45℃
- Measuring Range
- 0~100NTU
- Lead interface
- M12
- Dimensions
- 140*140*320mm
Flow-through laser turbidimeter for freshwater low turbidity
Daruifuno OLTU600 flow-through turbidimeter with 660nm laser, 0~100NTU range, and RS485 Modbus interface for freshwater monitoring.
Overview. The Daruifuno OLTU600 turbidimeter is a flow-through optical instrument designed for detecting low turbidity levels in freshwater and drinking water supplies.
Sensing and accuracy. Featuring a 660nm laser light source directed vertically into the water stream, it delivers 0.001NTU resolution over a 0~100NTU range switchable to 0~5NTU or 0~10NTU. Measurement accuracy reaches ± 2% or ± 0.015NTU under 100~700mL/min flow.
Integration and construction. Equipped with an M12 connector and RS485 Modbus protocol, the sensor operates on 9~18VDC over 0~45℃. The enclosure measures 140*140*320mm, weighs 2100g, and is rated IP65.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 5NTU, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Dimensions | 140*140*320mm |
| Accuracy | 0.001~40NTU is ± 2% of the reading or ± 0.015NTU, take the larger one |
| Calibration | Multi-point calibration; Contrast Offset; Factor offset |
| Flow requirement | 100~700mL/min |
| Lead interface | M12 |
| Measuring Principle | 660nm laser scattering principle |
| Measuring Range | 0~100NTU |
| Operating Temperature | 0~45℃ |
| Option | No display screen; With OLED display screen |
| Power supply | 9~18VDC |
| Product Model | OLTU600 |
| Protection Grade | IP65 (indoor) |
| Resolution | 0.001NTU |
| Shaft material | POM+nylon+ABS+stainless steel |
| Signal Type | Digital RS485 Modbus |
| We will contact you immediately | Fill in more information so that we can get in touch with you faster |
| Weight | 2100g |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for 5NTU. For a missing document or a specific revision, our experts send it to you.
Daruifuno OLTU600 flow-through turbidimeter with 660nm laser, 0~100NTU range, and RS485 Modbus interface for freshwater monitoring.
| Parameter | Value |
|---|---|
| Dimensions | 140*140*320mm |
| Accuracy | 0.001~40NTU is ± 2% of the reading or ± 0.015NTU, take the larger one |
| Calibration | Multi-point calibration; Contrast Offset; Factor offset |
| Flow requirement | 100~700mL/min |
| Lead interface | M12 |
| Measuring Principle | 660nm laser scattering principle |
| Measuring Range | 0~100NTU |
| Operating Temperature | 0~45℃ |
| Option | No display screen; With OLED display screen |
| Power supply | 9~18VDC |
| Product Model | OLTU600 |
| Protection Grade | IP65 (indoor) |
| Resolution | 0.001NTU |
| Shaft material | POM+nylon+ABS+stainless steel |
| Signal Type | Digital RS485 Modbus |
| We will contact you immediately | Fill in more information so that we can get in touch with you faster |
| Weight | 2100g |
Points to check before using 5NTU in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | 9~18VDC |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of 5NTU can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Signal Type": Digital RS485 Modbus.
Yes — recorded under "We will contact you immediately": Fill in more information so that we can get in touch with you faster.
Yes — recorded under "Signal Type": Digital RS485 Modbus.
0~45℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Flow-through laser turbidimeter for freshwater low turbidity

Laser Flow-through Turbidity Sensor for Drinking Water

OLED Display Inline Turbidity Sensor for Drinking Water

Raw Water 0~10NTU Laser Optical Turbidity Sensor with Display

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 5NTU |
| Manufacturer | Daruifuno |
Turbidity Sensors
Online turbidity sensor with RS485 and 90-degree optical measurement · Ref. : WQ-TS-4A
Price on request
Turbidity Sensors
Industrial RS485 Modbus-RTU Turbidity Sensor IP68
Price on request
Turbidity Sensors
Water Turbidity Sensor, RS485 Output, IP68 · Ref. : RK500-07
Price on request
Turbidity Sensors
IoT digital turbidity sensor with infrared scattered light
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details