OLTU610
Digital laser turbidity sensor with flow-through design

- Measurement Range
- 0.001~100 NTU (Resolution: 0.001 NTU)
- Storage Temperature
- -10°C to +60°C
- Dimensions
- 140x140x330 mm
- Mounting
- Wall-mounted
Digital laser turbidity sensor with flow-through design
Daruifuno OLTU610 digital laser turbidity sensor with flow-through design for continuous water clarity measurement, with RS485 Modbus-RTU output and wall mounting.
Laser turbidity sensor OLTU610. The Daruifuno OLTU610 digital laser turbidity sensor is designed for water quality monitoring, with a flow-through design and an OLED display. Measurement and accuracy — The measurement range covers 0.001 to 100 NTU with a resolution of 0.001 NTU. Accuracy is ±2% of reading or ±0.015 NTU, whichever is greater, between 0.001 and 40 NTU. The initial response time is under 60 seconds. Connectivity and power — The sensor communicates over RS485 using the Modbus-RTU protocol and operates from a 9 to 18 VDC power supply. Installation and environment — The recommended sample flow rate is 100 to 700 mL/min, ideally 200 to 300 mL/min, with an inlet pressure between 1 and 2 bar. The ABS and SS304 body measures 140 x 140 x 330 mm and is wall-mounted. It operates between 0 and 50 °C and stores between -10 and +60 °C. Typical uses — It suits drinking water monitoring, treatment installations and monitoring systems connected to a PLC via Modbus-RTU.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for OLTU610, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Dimensions | 140x140x330 mm |
| Mounting | Wall-mounted |
| Response time | Initial response time < 60 seconds |
| Accuracy | 0.001~40 NTU: ±2% of reading or ±0.015 NTU, whichever is greater |
| Body Material | ABS + SS304 |
| Communication Protocol | RS485 Modbus-RTU |
| Measurement Range | 0.001~100 NTU (Resolution: 0.001 NTU) |
| Power supply | 9~18 VDC |
| Recommended Sample Flow Rate | 100 to 700 mL/min; Ideal: 200 to 300 mL/min |
| Sample Pressure | Ensure sample pressure between 1~2 Bar at the inlet |
| Storage Temperature | -10°C to +60°C |
| We will contact you immediately | Fill in more information so that we can get in touch with you faster |
| Working temperature | 0~50°C |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for OLTU610. For a missing document or a specific revision, our experts send it to you.
Daruifuno OLTU610 digital laser turbidity sensor with flow-through design for continuous water clarity measurement, with RS485 Modbus-RTU output and wall mounting.
| Parameter | Value |
|---|---|
| Dimensions | 140x140x330 mm |
| Mounting | Wall-mounted |
| Response time | Initial response time < 60 seconds |
| Accuracy | 0.001~40 NTU: ±2% of reading or ±0.015 NTU, whichever is greater |
| Body Material | ABS + SS304 |
| Communication Protocol | RS485 Modbus-RTU |
| Measurement Range | 0.001~100 NTU (Resolution: 0.001 NTU) |
| Power supply | 9~18 VDC |
| Recommended Sample Flow Rate | 100 to 700 mL/min; Ideal: 200 to 300 mL/min |
| Sample Pressure | Ensure sample pressure between 1~2 Bar at the inlet |
| Storage Temperature | -10°C to +60°C |
| We will contact you immediately | Fill in more information so that we can get in touch with you faster |
| Working temperature | 0~50°C |
Points to check before using OLTU610 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power supply | 9~18 VDC |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of OLTU610 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication Protocol": RS485 Modbus-RTU.
Yes — recorded under "We will contact you immediately": Fill in more information so that we can get in touch with you faster.
Yes — recorded under "Communication Protocol": RS485 Modbus-RTU.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Digital laser turbidity sensor with flow-through design

Infrared Turbidity (Suspended Solids) Sensor - Model:

Drinking Water Turbidity Sensor & Probe -

Water Turbidity Sensor and Probe

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | OLTU610 |
| Manufacturer | Daruifuno |
Turbidity Sensors
Online turbidity sensor with RS485 and 90-degree optical measurement · Ref. : WQ-TS-4A
Price on request
Turbidity Sensors
Industrial RS485 Modbus-RTU Turbidity Sensor IP68
Price on request
Turbidity Sensors
Water Turbidity Sensor, RS485 Output, IP68 · Ref. : RK500-07
Price on request
Turbidity Sensors
IoT digital turbidity sensor with infrared scattered light
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details