PG13.5
High Temperature Analog pH Sensor for Pure Water

- Measuring Range
- 0~14pH
- Dimensions
- Diameter 12mm / Length120mm (customized)
- Indicator Electrode
- Low impedance cylindrical glass membrane
- Installation
- PG13.5 mounting thread or Anti-twist cap
High Temperature Analog pH Sensor for Pure Water
Glass-body analog pH sensor for measuring the pH of pure water at high temperature, used in power plant cooling and boiler feed circuits, semiconductor ultrapure water and pharmaceutical pure water preparation.
Daruifuno ASP129E. analog pH sensor for pure water. The ASP129E is a glass-body combination pH electrode designed for measuring the pH of pure water in high temperature environments.
Measurement. Measuring range 0 to 14 pH, low impedance cylindrical glass membrane indicator electrode, large sensing area, fast response and high strength. Slope above 95 % in pH 4.01 and pH 6.86 buffer solutions, zero point at pH 6.86 ± 0.3 pH.
Reference and materials. Ag/AgCl reference electrode with KCl gel electrolyte and double salt bridge system. The junction is a ceramic sand core, less prone to blocking. Glass body and glass shaft, glass and ceramic materials.
Operating conditions. Operating temperature 0 to 100 ℃ in continuous operation in a medium and low temperature environment, maximum working pressure 0 to 6 bar, sample flow velocity between 0.001 m/s and 0.5 m/s.
Connection and installation. Diameter 12 mm and length 120 mm (customized). Mounting by PG13.5 thread or anti-twist cap. Integral or split version, signal cable supporting lengths up to 60 meters, analog output. PT100, PT1000 or NTC10K temperature sensors available on request.
Typical uses. Monitoring the pH of pure water in power plant cooling and boiler feed systems, in ultrapure water systems of the semiconductor industry and in pure water preparation for the pharmaceutical industry.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for PG13.5, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Dimensions | Diameter 12mm / Length120mm (customized) |
| Indicator Electrode | Low impedance cylindrical glass membrane |
| Installation | PG13.5 mounting thread or Anti-twist cap |
| Materials | Glass+ceramic sand core |
| Measuring Range | 0~14pH |
| Operate Temp. | Medium and low temp environment: 0~100℃, continuous work |
| Option | Integral; Split |
| Product Model | ASP129E |
| Reference system | Ag/AgCl reference electrode, double salt bridge, KCl gel |
| Sample flow rate | 0.5 m/s ≥ flow velocity ≥ 0.001 m/s |
| Shaft material | glass |
| Signal Lead | Support orders within 60 meters |
| Signal Type | Analog |
| slope(SLOP)% | pH4.01 pH6.86 buffer solution:>95% |
| Tail Lead | Integral or split |
| Temperature Unit | PT100, PT1000, NTC10K customized |
| We will contact you immediately | Fill in more information so that we can get in touch with you faster |
| Working Pressure | Medium and low temp environment: max. 0~6bar |
| Zero(E0)pH | pH6.86 buffer solution:6.86±0.3 pH |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for PG13.5. For a missing document or a specific revision, our experts send it to you.
Glass-body analog pH sensor for measuring the pH of pure water at high temperature, used in power plant cooling and boiler feed circuits, semiconductor ultrapure water and pharmaceutical pure water preparation.
| Parameter | Value |
|---|---|
| Dimensions | Diameter 12mm / Length120mm (customized) |
| Indicator Electrode | Low impedance cylindrical glass membrane |
| Installation | PG13.5 mounting thread or Anti-twist cap |
| Materials | Glass+ceramic sand core |
| Measuring Range | 0~14pH |
| Operate Temp. | Medium and low temp environment: 0~100℃, continuous work |
| Option | Integral; Split |
| Product Model | ASP129E |
| Reference system | Ag/AgCl reference electrode, double salt bridge, KCl gel |
| Sample flow rate | 0.5 m/s ≥ flow velocity ≥ 0.001 m/s |
| Shaft material | glass |
| Signal Lead | Support orders within 60 meters |
| Signal Type | Analog |
| slope(SLOP)% | pH4.01 pH6.86 buffer solution:>95% |
| Tail Lead | Integral or split |
| Temperature Unit | PT100, PT1000, NTC10K customized |
| We will contact you immediately | Fill in more information so that we can get in touch with you faster |
| Working Pressure | Medium and low temp environment: max. 0~6bar |
| Zero(E0)pH | pH6.86 buffer solution:6.86±0.3 pH |
Answers to the questions that the recorded characteristics of PG13.5 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "We will contact you immediately": Fill in more information so that we can get in touch with you faster.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
High Temperature Analog pH Sensor for Pure Water

Series pH ORP Controller & Transmitter


Power Plant Water Ph Controller

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | PG13.5 |
| Manufacturer | Daruifuno |
pH Sensors
Industrial soil monitoring station with RS485 interface
Price on request
pH Sensors
Industrial Online ORP Sensor with Platinum Bulb
Price on request
pH Sensors
Chemical-Resistant UHF RFID Hard Tag for Metal Surfaces
Price on request
pH Sensors
Analog Composite Glass pH Electrode · Ref. : ASP200
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details