Online digital UV absorption COD sensor with RS485 IP68
Water Quality Analyzers and Probes
Online digital sensor measuring COD (up to 1~1500mg/L) and TOC via UV254 ultraviolet absorption with turbidity compensation and automatic cleaning.
Overview. The Daruifuno COD351 online digital sensor provides continuous monitoring of chemical oxygen demand (COD) and total organic carbon (TOC) using the UV254 ultraviolet absorption method. A secondary reference light beam automatically compensates for sample turbidity caused by suspended solids.
Measuring Ranges and Accuracy. Available in COD351L (COD 0.75~500mg/L, TOC 0.3~200mg/L, turbidity 0~300NTU) and COD351H (COD 1~1500mg/L, TOC 0.4~600mg/L, turbidity 0~1000NTU) versions, it achieves a resolution of 0.01mg/L and an accuracy of ±3% or 0.5mg/L.
Construction and Integration. Built with a 316L stainless steel housing (60mm diameter, 215mm length) rated IP68, it features an integrated rubber scraper for automatic underwater cleaning. Powered by 12~24V DC, it outputs data via RS485 Modbus RTU and operates at 0~ 45℃ up to 1Bar pressure (5 meters or 10 meters cable).
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for UV254NM, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy(COD) | ±3% or 0.5mg/L |
| Cable Length | 10m(custom) |
| Cleaning method | Rubber scraper |
| Dimension | Diameter 60mm, length 215mm |
| Measuring Principle | UV254 ultraviolet absorption method |
| Measuring Range | 1~1500mg/L |
| Measuring Range(COD) | COD351L: 0.75~500mg/L COD351H: 1~1500mg/L |
| Measuring Range(TOC) | COD351L: 0.3~200mg/L COD351H: 0.4~600mg/L |
| Measuring Range(TU) | COD351L: 0~300NTU COD351H: 0~1000NTU |
| Operating Temperature | 0~ 45℃ |
| Option | 5 meters; 10 meters |
| Output | RS485, Modbus RTU protocol |
| Power | 12~24V DC |
| Protection Grade | IP68 |
| Resolution(COD) | 0.01mg/L |
| Resolution(TOC) | 0.01mg/L |
| Shell material | 316L |
| We will contact you immediately | Fill in more information so that we can get in touch with you faster |
| Working Pressure | 1Bar |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for UV254NM. For a missing document or a specific revision, our experts send it to you.
Online digital sensor measuring COD (up to 1~1500mg/L) and TOC via UV254 ultraviolet absorption with turbidity compensation and automatic cleaning.
| Parameter | Value |
|---|---|
| Accuracy(COD) | ±3% or 0.5mg/L |
| Cable Length | 10m(custom) |
| Cleaning method | Rubber scraper |
| Dimension | Diameter 60mm, length 215mm |
| Measuring Principle | UV254 ultraviolet absorption method |
| Measuring Range | 1~1500mg/L |
| Measuring Range(COD) | COD351L: 0.75~500mg/L COD351H: 1~1500mg/L |
| Measuring Range(TOC) | COD351L: 0.3~200mg/L COD351H: 0.4~600mg/L |
| Measuring Range(TU) | COD351L: 0~300NTU COD351H: 0~1000NTU |
| Operating Temperature | 0~ 45℃ |
| Option | 5 meters; 10 meters |
| Output | RS485, Modbus RTU protocol |
| Power | 12~24V DC |
| Protection Grade | IP68 |
| Resolution(COD) | 0.01mg/L |
| Resolution(TOC) | 0.01mg/L |
| Shell material | 316L |
| We will contact you immediately | Fill in more information so that we can get in touch with you faster |
| Working Pressure | 1Bar |
Points to check before using UV254NM in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Power | 12~24V DC |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of UV254NM can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Output": RS485, Modbus RTU protocol.
Yes — recorded under "We will contact you immediately": Fill in more information so that we can get in touch with you faster.
Yes — recorded under "Output": RS485, Modbus RTU protocol.
0~ 45℃ (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Online digital UV absorption COD sensor with RS485 IP68

Online Fluoride Ion Analyzer for Drinking Water

Online COD Controller

Water Quality Monitor

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | UV254NM |
| Manufacturer | Daruifuno |
Water Quality Analyzers and Probes
Online UV fluorescence BOD sensor, reagent-free · Ref. : WQ-BOD-4S
Price on request
Water Quality Analyzers and Probes
Portable ORP analyzer with digital electrode and touch screen
Price on request
Water Quality Analyzers and Probes
Multiparameter Water Quality Sensor · Ref. : KPS-400
Price on request
Water Quality Analyzers and Probes
316L Online Digital ORP Sensor for Water Measurement · Ref. : DRH890
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details