DFRobot SEN0492 industrial laser distance sensor measuring 4 to 400 cm with ±2 cm accuracy, featuring an RS485 Modbus-RTU interface and an IP67 housing for automation.
Communication interfaceRS485
Power Supply Voltage6-36 V
Working current<38mA
Frequency20Hz (default)
Measurement Accuracy±2 cm
Baud rate2400-921600 optional 115200 (default)
Product overview
Overview. The DFRobot SEN0492 industrial laser distance sensor is an RS485 Modbus-RTU laser range sensor designed for distance measurement from 4 to 400 cm with ±2 cm accuracy. Its threaded metal housing includes an optical filter cover that reduces the influence of ambient light.
Main characteristics. Measuring range of 4 to 400 cm, accuracy of ±2 cm, emitting angle of 39.6° and receiving angle of 36.5°. Default frequency of 20 Hz, working current below 38 mA, dimensions of 21.5 × 21 × 8 mm. Measurements become unstable on black objects.
Interfaces and connectivity. RS485 communication interface with Modbus-RTU protocol, allowing connection to a programmable logic controller or an industrial gateway. Configurable baud rate from 2400 to 921600, default 115200. An alarm output can switch to a low level when the measured distance falls below a configured threshold.
Power and environment. Power supply from 6 to 36 V, operating temperature range of -20 to 70 °C, IP67 waterproof rating.
Typical uses. Obstacle detection, positioning of automated equipment and distance monitoring in automation systems, particularly where an RS485 Modbus-RTU link is required.
Integration. The sensor connects directly to an existing RS485 network. Available on quotation from Atlas Electronics.
DFRobot SEN0492 industrial laser distance sensor measuring 4 to 400 cm with ±2 cm accuracy, featuring an RS485 Modbus-RTU interface and an IP67 housing for automation.
Communication interfaceRS485
Power Supply Voltage6-36 V
Working current<38mA
Frequency20Hz (default)
Measurement Accuracy±2 cm
2. Datasheet extract (recorded values)
Parameter
Value
Baud rate
2400-921600 optional 115200 (default)
Communication interface
RS485
Communication Protocol
Modbus-RTU
Emitting Angle
39.6°
Frequency
20Hz (default)
Measurement Accuracy
±2 cm
Measuring Distance
4-400 cm
Power Supply Voltage
6-36 V
Receiving Angle
36.5°
Size
21.5×21×8 mm / 0.85×0.83×0.31 inch
Waterproof rating
IP67
Wide operating voltage
6–36 V
Working current
<38mA
Working temperature
-20~70°C
Integration
Points to check before using SEN0492 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with 6-36 V.
Power and communication
Power Supply Voltage
6-36 V
Wide operating voltage
6–36 V
Working current
<38mA
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with 6-36 V.
Applications and use cases
Architectures in which SEN0492 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
A proprietary PLC locks the project into one vendor’s tools. Industrial controllers built on the Raspberry Pi Compute Module run Linux, Node-RED, Python or CODESYS on DIN rail, with I/O modules, an operator panel and a cellular router for remote access
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details