I2C indoor air quality sensor measuring total volatile organic compounds (TVOC), equivalent CO2 (eCO2) and the AQI index, intended for air monitoring in indoor environments.
Operating Temperature-10℃~80℃
TVOC Detection Range0ppb~65000ppb
Supply voltage3.3V~5V
Operating Current29mA
Cable Length1m
Communication modeI2C
Product overview
Overview. The DFRobot SEN0537 (ENS160) indoor air quality sensor is an I2C sensor based on the ScioSense ENS160 chip. It directly outputs TVOC, eCO2 and AQI data using TrueVOC™ technology combined with metal oxide (MOX) technology and on-chip algorithms.
Main characteristics. TVOC detection range of 0 to 65000 ppb and eCO2 detection range of 400 to 65000 ppm. The sensor includes automatic baseline correction for better stability during long-term use. Preheat time of less than 3 minutes.
Interfaces and connectivity. I2C communication, I2C address 0x53, cable length of 1 m.
Power and environment. Supply voltage of 3.3 V to 5 V, operating current of 29 mA. Operating temperature of -10 °C to 80 °C, operating humidity of 5%RH to 95%RH non-condensing.
Typical uses. Air purifiers and home automation devices, environmental pollution detection, HVAC and ventilation systems, building automation and smart thermostats, electrical appliances and range hoods.
Integration. Probe shape for easier installation. The sensor is supplied as one I2C ENS160 air quality sensor and is CE and RoHS certified.
I2C indoor air quality sensor measuring total volatile organic compounds (TVOC), equivalent CO2 (eCO2) and the AQI index, intended for air monitoring in indoor environments.
Operating Temperature-10℃~80℃
TVOC Detection Range0ppb~65000ppb
Supply voltage3.3V~5V
Operating Current29mA
Cable Length1m
2. Datasheet extract (recorded values)
Parameter
Value
Supply voltage
3.3V~5V
Cable Length
1m
Communication mode
I2C
I2C Address
0x53
Operating Current
29mA
Operating Humidity
5%RH~95%RH (Non-condensing)
Operating Temperature
-10℃~80℃
Preheat time
<3 minutes
TVOC Detection Range
0ppb~65000ppb
Integration
Points to check before using SEN0537 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with 3.3V~5V.
2Thermalrated operating range -10℃~80℃ — check it against the installation environment.
Power and communication
Supply voltage
3.3V~5V
Operating Current
29mA
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with 3.3V~5V.
Thermal : rated operating range -10℃~80℃ — check it against the installation environment.
Applications and use cases
Architectures in which SEN0537 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for SEN0537 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details