MEMS volatile organic compounds sensor for indoor air quality monitoring and gas detection in compact modules. Available on quotation from Atlas Electronics.
Operating Temperature-10-50℃
Detection range1-500ppm
Operating Current<20mA
Dimension13×13 x 2.5mm/0.0.51×0.51x0.1"
Gas detectedethanol, formaldehyde, toluene, etc
Lifespan≥5 years (in air)
Product overview
Overview. The DFRobot SEN0566 is a volatile organic compounds (VOC) detector based on MEMS technology, supplied as a breakout module. Its detection range is 1 to 500 ppm. It provides qualitative measurements only.
Main characteristics. Dimensions of 13×13 mm with a thickness of 2.5 mm. Operating current below 20 mA. Analog voltage output, supply voltage of 3.3 to 5 V. Sensitivity R0 (in air) / Rs (in 50 ppm ethanol) of 3 or more. Lifespan of 5 years or more in air.
Detected gases and uses. The sensor detects ethanol, formaldehyde and toluene, among others. It can be used to measure formaldehyde concentration in indoor air, to identify the sources and levels of benzene in ambient air, and to detect leaks or spills of tetrachloroethylene in industrial safety contexts.
Operating conditions. Operating temperature of -10 to 50 °C and humidity of 15 to 90 %RH, non-condensing. The protective film should be removed before use. Avoid volatile silicon compound vapours, high concentrations of corrosive gases, contact with water or condensation, and excessive vibration. For extended periods without use, preheat the module for at least 24 hours. The manufacturer specifies that this module must not be used in systems involving personal safety.
MEMS volatile organic compounds sensor for indoor air quality monitoring and gas detection in compact modules. Available on quotation from Atlas Electronics.
Operating Temperature-10-50℃
Detection range1-500ppm
Operating Current<20mA
Dimension13×13 x 2.5mm/0.0.51×0.51x0.1"
Gas detectedethanol, formaldehyde, toluene, etc
2. Datasheet extract (recorded values)
Parameter
Value
Detection range
1-500ppm
Dimension
13×13 x 2.5mm/0.0.51×0.51x0.1"
Environmental Monitoring
identify the sources and levels of benzene in the ambient air
measure the concentration of formaldehyde in the indoor air
Industrial safety
detect any leaks or spills of tetrachloroethylene
Lifespan
≥5 years (in air)
Operating Current
<20mA
Operating Humidity
15-90%RH (non-condensing)
Operating Temperature
-10-50℃
Operating Voltage
3.3-5V
Output signal
Analog voltage
Sensitivity
R0 (in air)/Rs (in 50ppm ethanol) ≥ 3
Integration
Points to check before using SEN0566 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -10-50℃ — check it against the installation environment.
Power and communication
Operating Current
<20mA
Operating Voltage
3.3-5V
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -10-50℃ — check it against the installation environment.
Applications and use cases
Architectures in which SEN0566 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for SEN0566 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productDFRobot
SEN0566
MEMS VOC Gas Sensor, Qualitative Detection, 1-500 ppm
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details