SEN0641 – RS485 PAR sensor for photosynthetically active radiation 400-700 nm

RS485 PAR sensor for photosynthetically active radiation 400-700 nm

Modular DIN-Rail Remote I/O Modules

  • -25°C to +60°C
  • 0-2500 µmol/m²·s
  • 400-700nm
  • <10mA
Manufacturer part number
SEN0641
Manufacturer
DFRobot
Operating Temperature
-25°C to +60°C
Measurement Range
0-2500 µmol/m²·s

Photosynthetically active radiation (PAR) sensor with RS485 Modbus-RTU output, designed to measure the light usable by plants between 400 and 700 nm.

Product overview

Overview. The DFRobot SEN0641 RS485 PAR sensor is a photosynthetically active radiation (PAR) sensor that measures the amount of light plants can use during photosynthesis, within the 400 to 700 nm spectral range. It converts incident radiation into a signal proportional to its intensity, with a sensitivity that follows the cosine of the angle of incidence.

Measurement characteristics. The measurement range is 0 to 2500 µmol/m²·s, with a resolution of 1 µmol/m²·s and an accuracy of ±5% (1000 µmol/m²·s at 550 nm, 60%RH, 25°C). Non-linearity is below ±1%, cosine response is at most ±10% and annual stability is at most ±2%. The response time is 10 µs.

Interfaces and connectivity. The sensor communicates over RS485 using the Modbus-RTU protocol. The sensor cable is 20 cm long and the adapter cable is 70 cm long.

Power and environment. It operates from a DC supply of 5 to 30 V, with a working current below 10 mA. Its operating temperature range is -25°C to +60°C and its protection level is IP67, thanks to an aluminium shell and a specially treated dust cover.

Typical uses. The sensor suits light monitoring for agricultural and plant growth applications, as well as solar radiation monitoring for photovoltaic systems and environmental research.

Integration. With its RS485 Modbus-RTU interface and 5 to 30 V supply, the sensor can be connected to a PLC, a controller or an Arduino-type platform for data collection. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Response time: 10 µs
  • Accuracy: ±5% (1000 µmol/m²·s @ 550nm, 60%RH, 25°C)
  • Adapter Cable Length: 70cm
  • Annual Stability: ≤±2%
  • Cosine response: ≤±10%
  • Measurement Range: 0-2500 µmol/m²·s

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -25°C to +60°C — check it against the installation environment.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote