Two-channel on/off 5A lighting controller for ceiling installation, wirelessly controlled over 433MHz RF to switch LED or resistive lighting loads.
Operating Temperature-20℃ ~ +55℃
Operating Current2*5A
Radio FrequencyRF 433MHz
Memory CapacityMaximum 10 switches
DimensionsL88.8*W43.7*H30.9mm
Power supplyAC100V ~ 240V 50/60Hz
Product overview
Overview. The Ebelong ERC603, from the C6 series, is a dual on/off lighting controller, a wireless control module installed in the ceiling. It switches two channels of 5A each.
Main characteristics. Each channel supports an LED load of up to 600W and a resistive load of up to 1100W at 220V. It stores up to 10 switches in memory. Its operating range is up to 80m outdoors and up to 25m indoors, depending on conditions.
Interfaces and connectivity. Wireless communication uses 433MHz radio frequency. The controller is compatible with the Ebelong smart home protocol and can be paired with an optional gateway for control by smartphone app, as well as by voice assistants Google Assistant and Amazon Alexa.
Power and environment. It operates on AC 100V to 240V, 50/60Hz, over an operating temperature range of -20℃ to +55℃. Its dimensions are 88.8 x 43.7 x 30.9 mm. An interchangeable fuse protects against short circuits, and a fuse box cover allows external installation and easy fuse replacement.
Compliance. The product complies with EN 60669-1:2018 and EN 60669-2-1:2004+A1:2009+A12:2010, with the electromagnetic compatibility standards ETSI EN 301489-1, EN 55032:2015 and EN 55035:2017, and with the radio standards ETSI EN 300220-1 and ETSI EN 300220-2.
Typical uses. The controller allows each room to be equipped with smart lighting without control wiring between the switch and the load, thanks to the radio link.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for C6-5A-ON-OFF-DUAL-CONTROLLER, with where it comes from. Use the filters to find one quickly.
All specifications (11)
Characteristic
Value
Dimensions
L88.8*W43.7*H30.9mm
Certifications and standards
Europe; EN 60669-1:2018; EN 60669-2-1:2004+A1:2009+A12:2010; ETSI EN 301489-1 V2.2.3(2019-11); ETSI EN 301489-1 V2.1.1(2019-03); EN 55032:2015; EN 55035:2017; EN IEC 61000-3-2:2019; EN 61000-3-3:2013+2019; ETSI EN 300220-1 V3.1.1(2017-02); ETSI EN 300220-2 V3.2.1(2018-06)
Maximum Output Power
LED load: 2*600W (220V~); Resistive load: 2*1100W (220V~)
Memory Capacity
Maximum 10 switches
Operating Current
2*5A
Operating Range
Up to 80m outdoors; Up to 25m indoors; (May vary depending on conditions)
Operating Temperature
-20℃ ~ +55℃
Power supply
AC100V ~ 240V 50/60Hz
Product Model
ERC603
Radio Frequency
RF 433MHz
Working hours
Monday to Friday 8:30~18:00
No specification matches.
Last verification : 2026-11-03
Integration
Points to check before using C6-5A-ON-OFF-DUAL-CONTROLLER in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -20℃ ~ +55℃ — check it against the installation environment.
Power and communication
Maximum Output Power
LED load: 2*600W (220V~); Resistive load: 2*1100W (220V~)
Operating Current
2*5A
Power supply
AC100V ~ 240V 50/60Hz
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20℃ ~ +55℃ — check it against the installation environment.
Applications and use cases
Architectures in which C6-5A-ON-OFF-DUAL-CONTROLLER can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Hotel rooms keep heating, cooling and lights on while empty. A room control system links thermostats, switches, door contacts and lighting controllers so the room adapts to the guest’s presence
To check
Wired bus or wireless system, depending on renovation or new build
Link with the property management system for check-in and check-out
Behaviour when the guest is absent (setback temperature, lights off)
Associated system blocks
Climate controlSwitches and panelsPresence detectionLighting control
Street lights burn at full power all night. Lighting controllers on each luminaire, linked by LoRaWAN, dim, switch and report each light from a central platform
To check
Socket type on the luminaires (NEMA or Zhaga)
Dimming interface of the drivers
Gateway coverage across the network of streets
Associated system blocks
Luminaire controllersGateway
Need a complete solution?
Send a request for C6-5A-ON-OFF-DUAL-CONTROLLER and the other parts of your project.
Answers to the questions that the recorded characteristics of C6-5A-ON-OFF-DUAL-CONTROLLER can answer. A question is not asked when nothing is recorded to answer it.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Europe; EN 60669-1:2018; EN 60669-2-1:2004+A1:2009+A12:2010; ETSI EN 301489-1 V2.2.3(2019-11); ETSI EN 301489-1 V2.1.1(2019-03); EN 55032:2015; EN 55035:2017; EN IEC 61000-3-2:2019; EN 61000-3-3:2013+2019; ETSI EN 300220-1 V3.1.1(2017-02); ETSI EN 300220-2 V3.2.1(2018-06)
Dimensions
L88.8*W43.7*H30.9mm
Maximum Output Power
LED load: 500W (220V~); Resistive load: 1100W (220V~)
Europe; EN 60669-1:2018; EN 60669-2-1:2004+A1:2009+A12:2010; ETSI EN 301489-1 V2.2.3(2019-11); ETSI EN 301489-1 V2.1.1(2019-03); EN 55032:2015; EN 55035:2017; EN IEC 61000-3-2:2019; EN 61000-3-3:2013+2019; ETSI EN 300220-1 V3.1.1(2017-02); ETSI EN 300220-2 V3.2.1(2018-06)
Dimensions
L88.7*W43.9*H31mm
Maximum Output Power
LED load: 100W (220V~); Resistive load: 200W (220V~)
Europe; EN 60669-1:2018; EN 60669-2-1:2004+A1:2009+A12:2010; ETSI EN 301489-1 V2.2.3(2019-11); ETSI EN 301489-1 V2.1.1(2019-03); EN 55032:2015; EN 55035:2017; EN IEC 61000-3-2:2019; EN 61000-3-3:2013+2019; ETSI EN 300220-1 V3.1.1(2017-02); ETSI EN 300220-2 V3.2.1(2018-06)
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
Europe; EN 60669-1:2018; EN 60669-2-1:2004+A1:2009+A12:2010; ETSI EN 301489-1 V2.2.3(2019-11); ETSI EN 301489-1 V2.1.1(2019-03); EN 55032:2015; EN 55035:2017; EN IEC 61000-3-2:2019; EN 61000-3-3:2013+2019; ETSI EN 300220-1 V3.1.1(2017-02); ETSI EN 300220-2 V3.2.1(2018-06)Certifications and standards