Two-channel wireless lighting controller mounted on a DIN rail, designed to switch lighting loads from a new or renovated electrical panel.
Operating Temperature-20℃ ~ +55℃
Operating Current2*10A
Memory CapacityMaximum 10 switches
DimensionsL36*W77*H67mm
Power supplyAC100V ~ 240V 50/60Hz
Working hoursMonday to Friday 8:30~18:00
Product overview
Overview. The Ebelong ERC2102 is a 10 A two-channel on/off lighting controller mounted on a DIN rail type Ω EN 50022. It fits most electrical panels and suits new buildings as well as renovation projects. Main characteristics — It provides two 10 A channels, a memory capacity of up to 10 switches and a power supply of AC 100 V to 240 V, 50/60 Hz. Its dimensions are L36 × W77 × H67 mm. Power and environment — Maximum output power is 2 × 1000 W for LED loads and 2 × 2200 W for resistive loads at 220 V. The operating temperature range is -20 ℃ to +55 ℃. Operating range is up to 80 m outdoors and up to 25 m indoors, which may vary depending on conditions. Connectivity — Three versions are available: RF 433 MHz (ERC2102), WiFi 2.4G with RF 433 MHz (ERC2102-W) and ZigBee 2.4G with RF 433 MHz (ERC2102-Z). An optional gateway enables app and voice control (Google Assistant, Amazon Alexa). Standards — The product complies with EN 60669-1:2018, EN 60669-2-1:2004+A1:2009+A12:2010, EN 55032:2015, EN 55035:2017, EN IEC 61000-3-2:2019, EN 61000-3-3:2013+2019, ETSI EN 301489-1 V2.2.3 (2019-11), ETSI EN 301489-1 V2.1.1 (2019-03), ETSI EN 300220-1 V3.1.1 (2017-02) and ETSI EN 300220-2 V3.2.1 (2018-06). Typical uses — It adds control points wherever needed, provides countdown timing for lights or bathroom exhaust fans, supports presence simulation and turns off all lights with one click. It also suits garden lighting. Installation — Neutral, phase, input and output terminals simplify cabling to the electrical panel.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for RAIL-5A-ON-OFF-DUAL-CONTROLLER, with where it comes from. Use the filters to find one quickly.
All specifications (11)
Characteristic
Value
Dimensions
L36*W77*H67mm
Certifications and standards
Europe; EN 60669-1:2018; EN 60669-2-1:2004+A1:2009+A12:2010; ETSI EN 301489-1 V2.2.3(2019-11); ETSI EN 301489-1 V2.1.1(2019-03); EN 55032:2015; EN 55035:2017; EN IEC 61000-3-2:2019; EN 61000-3-3:2013+2019; ETSI EN 300220-1 V3.1.1(2017-02); ETSI EN 300220-2 V3.2.1(2018-06)
Maximum Output Power
LED load: 2*1000W (220V~); Resistive load: 2*2200W (220V~)
Memory Capacity
Maximum 10 switches
Operating Current
2*10A
Operating Range
Up to 80m outdoors; Up to 25m indoors; (May vary depending on conditions)
Operating Temperature
-20℃ ~ +55℃
Power supply
AC100V ~ 240V 50/60Hz
Product Model
RF version ERC2102; WiFi version ERC2102-W; ZigBee version ERC2102-Z
Official documents and the technical data recorded for RAIL-5A-ON-OFF-DUAL-CONTROLLER. For a missing document or a specific revision, our experts send it to you.
Two-channel wireless lighting controller mounted on a DIN rail, designed to switch lighting loads from a new or renovated electrical panel.
Operating Temperature-20℃ ~ +55℃
Operating Current2*10A
Memory CapacityMaximum 10 switches
DimensionsL36*W77*H67mm
Power supplyAC100V ~ 240V 50/60Hz
2. Datasheet extract (recorded values)
Parameter
Value
Dimensions
L36*W77*H67mm
Certifications and standards
Europe; EN 60669-1:2018; EN 60669-2-1:2004+A1:2009+A12:2010; ETSI EN 301489-1 V2.2.3(2019-11); ETSI EN 301489-1 V2.1.1(2019-03); EN 55032:2015; EN 55035:2017; EN IEC 61000-3-2:2019; EN 61000-3-3:2013+2019; ETSI EN 300220-1 V3.1.1(2017-02); ETSI EN 300220-2 V3.2.1(2018-06)
Maximum Output Power
LED load: 2*1000W (220V~); Resistive load: 2*2200W (220V~)
Memory Capacity
Maximum 10 switches
Operating Current
2*10A
Operating Range
Up to 80m outdoors; Up to 25m indoors; (May vary depending on conditions)
Operating Temperature
-20℃ ~ +55℃
Power supply
AC100V ~ 240V 50/60Hz
Product Model
RF version ERC2102; WiFi version ERC2102-W; ZigBee version ERC2102-Z
Points to check before using RAIL-5A-ON-OFF-DUAL-CONTROLLER in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -20℃ ~ +55℃ — check it against the installation environment.
Power and communication
Maximum Output Power
LED load: 2*1000W (220V~); Resistive load: 2*2200W (220V~)
Operating Current
2*10A
Power supply
AC100V ~ 240V 50/60Hz
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20℃ ~ +55℃ — check it against the installation environment.
Applications and use cases
Architectures in which RAIL-5A-ON-OFF-DUAL-CONTROLLER can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Hotel rooms keep heating, cooling and lights on while empty. A room control system links thermostats, switches, door contacts and lighting controllers so the room adapts to the guest’s presence
To check
Wired bus or wireless system, depending on renovation or new build
Link with the property management system for check-in and check-out
Behaviour when the guest is absent (setback temperature, lights off)
Associated system blocks
Climate controlSwitches and panelsPresence detectionLighting control
Street lights burn at full power all night. Lighting controllers on each luminaire, linked by LoRaWAN, dim, switch and report each light from a central platform
To check
Socket type on the luminaires (NEMA or Zhaga)
Dimming interface of the drivers
Gateway coverage across the network of streets
Associated system blocks
Luminaire controllersGateway
Need a complete solution?
Send a request for RAIL-5A-ON-OFF-DUAL-CONTROLLER and the other parts of your project.
Answers to the questions that the recorded characteristics of RAIL-5A-ON-OFF-DUAL-CONTROLLER can answer. A question is not asked when nothing is recorded to answer it.
1Does it include Wi-Fi?
Yes — recorded under "Product Model": RF version ERC2102; WiFi version ERC2102-W; ZigBee version ERC2102-Z.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productEbelong
RAIL-5A-ON-OFF-DUAL-CONTROLLER
Rail 2-channel on/off 10A wireless DIN rail controller
Europe; EN 60669-1:2018; EN 60669-2-1:2004+A1:2009+A12:2010; ETSI EN 301489-1 V2.2.3(2019-11); ETSI EN 301489-1 V2.1.1(2019-03); EN 55032:2015; EN 55035:2017; EN IEC 61000-3-2:2019; EN 61000-3-3:2013+2019; ETSI EN 300220-1 V3.1.1(2017-02); ETSI EN 300220-2 V3.2.1(2018-06)
Dimensions
L88.8*W43.7*H30.9mm
Maximum Output Power
LED load: 500W (220V~); Resistive load: 1100W (220V~)
Europe; EN 60669-1:2018; EN 60669-2-1:2004+A1:2009+A12:2010; ETSI EN 301489-1 V2.2.3(2019-11); ETSI EN 301489-1 V2.1.1(2019-03); EN 55032:2015; EN 55035:2017; EN IEC 61000-3-2:2019; EN 61000-3-3:2013+2019; ETSI EN 300220-1 V3.1.1(2017-02); ETSI EN 300220-2 V3.2.1(2018-06)
Dimensions
L88.7*W43.9*H31mm
Maximum Output Power
LED load: 100W (220V~); Resistive load: 200W (220V~)
Europe; EN 60669-1:2018; EN 60669-2-1:2004+A1:2009+A12:2010; ETSI EN 301489-1 V2.2.3(2019-11); ETSI EN 301489-1 V2.1.1(2019-03); EN 55032:2015; EN 55035:2017; EN IEC 61000-3-2:2019; EN 61000-3-3:2013+2019; ETSI EN 300220-1 V3.1.1(2017-02); ETSI EN 300220-2 V3.2.1(2018-06)
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
Europe; EN 60669-1:2018; EN 60669-2-1:2004+A1:2009+A12:2010; ETSI EN 301489-1 V2.2.3(2019-11); ETSI EN 301489-1 V2.1.1(2019-03); EN 55032:2015; EN 55035:2017; EN IEC 61000-3-2:2019; EN 61000-3-3:2013+2019; ETSI EN 300220-1 V3.1.1(2017-02); ETSI EN 300220-2 V3.2.1(2018-06)Certifications and standards
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details