Eeguard EC008S-Lift lift control device for controlling a lift door station or indoor phone through 16 relay outputs and a CAN bus.
Communication modeCAN bus
Communication Signal Isolation ModeOptoelectronic isolation
Dimension145x90x40mm
Extended lift control module quantity4 (Maximum support 64 floors)
Operating Humidity0%~95%
Power200mA(max), 30mA(standby)
Product overview
Overview. The Eeguard EC008S-Lift lift control device is a controller for installations where the user wants to control a lift door station or an indoor phone.
Main characteristics. The module provides 16 relay outputs (NO/NC optional), no screw needed, and can be extended with 4 lift control modules for a maximum of 64 floors. Its dimensions are 145x90x40 mm.
Interfaces and connectivity. Communication is carried over a CAN bus, with the communication signal isolated by optoelectronic isolation. The product supports a Wiegand 26/34 reader.
Power and environment. Powered by DC 18 to 36 V, with a maximum current of 200 mA and 30 mA in standby, for 2 W. It operates between -30 °C and +60 °C, at an operating humidity of 0% to 95%.
Typical uses. The device lets residents run a customer card and talk with a visitor and press the unlock button of the indoor phone, lets an administrator run an administration card through the outdoor station, and supports password unlock through the outdoor station.
Integration. The relay outputs connect directly to the lift control equipment.
Eeguard EC008S-Lift lift control device for controlling a lift door station or indoor phone through 16 relay outputs and a CAN bus.
Communication modeCAN bus
Communication Signal Isolation ModeOptoelectronic isolation
Dimension145x90x40mm
Extended lift control module quantity4 (Maximum support 64 floors)
Operating Humidity0%~95%
2. Datasheet extract (recorded values)
Parameter
Value
Communication mode
CAN bus
Communication Signal Isolation Mode
Optoelectronic isolation
Dimension
145x90x40mm
EC008S-Lift Control Device
Lift Control Device, It's applicated when user want to control lift door station or indoor phone
Extended lift control module quantity
4 (Maximum support 64 floors)
Lift Control Signal
16 channels relay output (NO/NC optional), no screw needed
Operating Humidity
0%~95%
Power
200mA(max), 30mA(standby)
Voltage
DC18-36V/2W
Working temperature
-30℃~+60℃
Applications and use cases
Architectures in which EC008S-LIFT can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Badges are lent and lost, and attendance is noted by hand. Face or fingerprint terminals, access controllers, door stations and locks control who enters and record working time
Announcements across a site need wiring that is hard to extend. IP speakers and paging systems use the data network, with intercoms and IP phones for calls
To check
Zones and sound level needed in each area
Power over Ethernet budget of the switches
Integration with the telephone system over SIP
Associated system blocks
Paging and speakersIntercoms and phones
Need a complete solution?
Send a request for EC008S-LIFT and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productEeguard
EC008S-LIFT
Lift control device with 16 relay outputs and CAN bus
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details