Limited record: this part has neither specifications nor a datasheet in the catalog yet. It is shown for reference and is not indexed.

N4ROF32 – 32-channel RS485 Modbus RTU relay output module

32-channel RS485 Modbus RTU relay output module

Relay Output Modules

  • RS-485
  • Modbus
Manufacturer part number
N4ROF32_12V
Manufacturer
Eletechsup

Mini 32-relay output module controlled over RS485 with Modbus RTU, designed to expand the outputs of a programmable logic controller (PLC) and switch loads.

Product overview

Overview. The Eletechsup N4ROF32 is a mini-format board with 32 relay outputs, controlled by the Modbus RTU protocol over an RS485 link and designed to expand the input-output capacity of a programmable logic controller (PLC).

Main characteristics. The board operates from a DC 12V or 24V supply. Each relay handles a maximum load of 2A (120VAC/2A or 24VDC/2A for resistive loads, 1A for inductive loads). Standby current is 4mA at DC 12V, and current rises by 20mA per open relay, reaching 432mA with 32 relays open. Eight commands are available: Open, Close, Momentary, Self-locking, Interlock, Delay, Open all and Close all.

Interfaces and connectivity. The RS485 link supports baud rates from 1200 to 115200 BPS (9600 by default) and parity None (default), Even and Odd. The standard Modbus RTU protocol supports write function codes 05, 06, 15, 16 and read function codes 01, 03. Up to 64 devices can operate in parallel on the same bus. Parameters, including the RS485 address, are set through a USB to RS485 interface. The maximum delay of the Delay command is 255 seconds.

Dimensions and mounting. The bare board measures 142 × 80 × 12 mm and weighs 138 g. With its DIN rail box it measures 145 × 88 × 36 mm and weighs 238 g. The terminals have a 3.96 mm pitch with 2.5 mm slotted screws.

Typical uses. The module extends the outputs of a PLC through its RS485 port, controls relay-switched devices in home automation and smart home systems, drives motors, LED lighting and automatic curtains, and controls PTZ CCTV cameras and security or identification systems.

Integration. Each board must be given a different RS485 address when several are connected on the same bus, whether driven by a PLC or by HMI configuration software.

Typical applications

Derived from the part category, not a compatibility statement.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Relay Output Modules
Request a quote