N4VIA02 – RS485 Modbus RTU Current and Voltage Measurement Module

RS485 Modbus RTU Current and Voltage Measurement Module

Modular DIN-Rail Remote I/O Modules

  • 0~30V;
  • 8-13MA;
  • Green
  • DIN35 and C45 rail
Manufacturer part number
N4VIA02_1A
Manufacturer
Eletechsup
Voltage measurement range
0~30V;
Power Supply Voltage
DC 8-25V(12V recommended);

RS485 Modbus RTU module for measuring voltage and current signals, intended for automation and monitoring on DIN rail.

Product overview

Overview. The Eletechsup N4VIA02 is a multifunction voltage and current measurement module with an RS485 Modbus RTU interface, designed for mounting on DIN35 or C45 rail.

Main characteristics. It measures voltages from 0 to 30 V and currents from 0 to 5 A with 1% accuracy. Available current ranges are 0-1 A, 0-2 A and 0-5 A; choosing the version with the smallest range that covers the measurement is recommended. If the read value differs considerably from the actual value, the module must be recalibrated.

Interfaces and connectivity. The module communicates over RS485 using the Modbus RTU protocol, with read command 03 and write commands 06/16. Baud rates are 1200, 2400, 9600 (default), 19200, 38400, 57600 and 115200, N/E/O, 8, 1. By changing the RS485 address, up to 247 modules can be cascaded; beyond 16 modules, an RS485 repeater is required.

Power and dimensions. It operates from 8-25 V DC (12 V recommended), drawing 8 to 13 mA. Dimensions: 72 x 47 x 12 mm board only, 87 x 50 x 37 mm with case. Weight: 23 g board only, 68 g with case. The module restores factory settings and restarts automatically 5 seconds after the RES port is shorted.

Typical uses. PLC I/O expansion, voltage and current monitoring of industrial control equipment, LED lamp driver control, and measurement in home automation systems.

Integration. Three wiring configurations are provided: voltage measurement only, current measurement only (the current signal voltage can be up to DC 0-110 V), or simultaneous voltage and current measurement. For 4-20 mA signal acquisition, the manufacturer refers to other modules in its range.

See all specifications

Highlights

  • Backplane length: suitable for 47 mm PCB boards
  • Color: Green
  • Installation: DIN35 and C45 rail
  • Insulation Grade: flame-retardant VO grade
  • MODBUS RTU protocol  please refer to: '' N4VIA02 Modbus RTU''
  • Net weight: 45g

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Power: plan for a supply compatible with DC 8-25V(12V recommended);.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote