Two-channel 5A DALI relay for switching lighting loads, connected to the DALI bus and powered from 90-240VAC.
Input Voltage90-240VAC
The input voltage90-240 v AC
Maximum Switching Current5A*2CH
Input Frequency50/60Hz
Communication ProtocolStandard DALI Agreement
Gross weight99g
Product overview
Euchips DALI-T02. The DALI-T02 is a two-channel DALI relay from Euchips, designed for switching lighting on a DALI bus.
Main characteristics. Each channel supports a maximum switching current of 5A, rated 5A*2 channels. The module operates on a wide supply range of 90-240VAC, with an input frequency of 50/60Hz.
Interfaces and connectivity. The module connects to the DALI bus using the standard DALI protocol, compliant with IEC62386. It occupies two addresses on the bus, and these addresses can be changed. It supports grouping and scene editing.
Power and environment. Working temperature range from -20 ℃ to 50 ℃, relative humidity from 20 to 90 %RH.
Mounting. Two mounting modes are available: guide rail and screw fixation.
Two-channel 5A DALI relay for switching lighting loads, connected to the DALI bus and powered from 90-240VAC.
Input Voltage90-240VAC
The input voltage90-240 v AC
Maximum Switching Current5A*2CH
Input Frequency50/60Hz
Communication ProtocolStandard DALI Agreement
2. Datasheet extract (recorded values)
Parameter
Value
Communication Protocol
Standard DALI Agreement
Gross weight
99g
Input Frequency
50/60Hz
Input Voltage
90-240VAC
Item No.
DALI-T02
Maximum Switching Current
5A*2CH
Next
40W 850/900/950/1000mA Triac & 0-10V CC Driver CUP40AT-1WMC
Packing Size
353*234*232mm (l * W * H)
Previous
8A*2ch CV 12-24VDC DMX Decoder PX0208
Relative humidity
20-90%RH
The equipment size
111*35*67mm (L * W * H)
The input voltage
90-240 v AC
Working temperature
- 20 ℃, 50 ℃
Applications and use cases
Architectures in which 90-240VAC can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Hotel rooms keep heating, cooling and lights on while empty. A room control system links thermostats, switches, door contacts and lighting controllers so the room adapts to the guest’s presence
To check
Wired bus or wireless system, depending on renovation or new build
Link with the property management system for check-in and check-out
Behaviour when the guest is absent (setback temperature, lights off)
Associated system blocks
Climate controlSwitches and panelsPresence detectionLighting control
Street lights burn at full power all night. Lighting controllers on each luminaire, linked by LoRaWAN, dim, switch and report each light from a central platform
To check
Socket type on the luminaires (NEMA or Zhaga)
Dimming interface of the drivers
Gateway coverage across the network of streets
Associated system blocks
Luminaire controllersGateway
Need a complete solution?
Send a request for 90-240VAC and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details