FT-S15S
Chlorophyll a fluorescence sensor with automatic self-cleaning

- Measuring Range
- 0-400ug/L
- Power consumption
- 0.4W,12V power supply
- Storage Temperature
- -5℃~65℃
- Accuracy
- R2>0.999
Chlorophyll a fluorescence sensor with automatic self-cleaning
Submersible chlorophyll a sensor for water using fluorescence, with RS-485 Modbus RTU output and automatic cleaning of the optical window for long-term monitoring.
Overview. The FT-S15S chlorophyll sensor from manufacturer Fengtu measures chlorophyll a content in water by fluorescence. Its principle relies on chlorophyll emitting fluorescence under illumination, the intensity of which is proportional to the measured content.
Main characteristics. Measuring range of 0 to 400 ug/L with a resolution of 0.01 ug/L and an accuracy of R2>0.999. Two-point calibration and automatic temperature compensation. 316L stainless steel shell.
Interfaces and connectivity. RS-485 output using the ModbusRTU protocol, 5 m cable with 4 shielded conductors.
Power and environment. DC power supply from 12 V to 24 V, consumption of 0.4 W at 12 V and 0.7 W for the automatic cleaner. Protection level IP68, working temperature from 0 to 50 °C, pressure below 0.2 MPa, storage temperature from -5 to 65 °C.
Self-cleaning. An automatic cleaner prevents biological adhesion and pollution of the light window; cleaning time and frequency can be set.
Installation. Submersible mounting with 3/4 NPT thread, at least 10 cm underwater, more than 3 cm from the side wall and more than 10 cm from the bottom, in fixed installation.
Typical uses. Monitoring of chlorophyll and algae in rivers, lakes, ponds, marine waters, aquaculture and drinking water sources, as well as in photovoltaic weather stations.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for FT-S15S, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | R2>0.999 |
| Cable Length | 5m |
| Calibration method | Two point calibration |
| Installation Method | Submersible installation, 3/4NPT mounting thread |
| Measurement Principle | Fluorescence method |
| Measuring Range | 0-400ug/L |
| Output mode | RS-485 (ModbusRTU protocol) |
| Photovoltaic Weather Stations | Collecting Environmental Data to Support the Stable Operation of Distributed PV Power Plants |
| Power consumption | 0.4W,12V power supply |
| powered by | DC: 12V~24V |
| Protection Level | IP68 |
| Resolution | 0.01ug/L |
| Self-cleaning function | Equipped with an automatic cleaner to prevent biological adhesion and light window pollution to ensure long-term monitoring stability; the automatic cleaning time and cleaning frequency can be set, and the power consumption is 0.7W |
| Shell material | 316L stainless steel |
| Storage Temperature | -5℃~65℃ |
| Temperature Compensation | Automatic temperature compensation |
| Water PH Sensor | Selection, Installation, and Maintenance |
| Working Environment | 0℃~50℃,<0.2MPa |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for FT-S15S. For a missing document or a specific revision, our experts send it to you.
Submersible chlorophyll a sensor for water using fluorescence, with RS-485 Modbus RTU output and automatic cleaning of the optical window for long-term monitoring.
| Parameter | Value |
|---|---|
| Accuracy | R2>0.999 |
| Cable Length | 5m |
| Calibration method | Two point calibration |
| Installation Method | Submersible installation, 3/4NPT mounting thread |
| Measurement Principle | Fluorescence method |
| Measuring Range | 0-400ug/L |
| Output mode | RS-485 (ModbusRTU protocol) |
| Photovoltaic Weather Stations | Collecting Environmental Data to Support the Stable Operation of Distributed PV Power Plants |
| Power consumption | 0.4W,12V power supply |
| powered by | DC: 12V~24V |
| Protection Level | IP68 |
| Resolution | 0.01ug/L |
| Self-cleaning function | Equipped with an automatic cleaner to prevent biological adhesion and light window pollution to ensure long-term monitoring stability; the automatic cleaning time and cleaning frequency can be set, and the power consumption is 0.7W |
| Shell material | 316L stainless steel |
| Storage Temperature | -5℃~65℃ |
| Temperature Compensation | Automatic temperature compensation |
| Water PH Sensor | Selection, Installation, and Maintenance |
| Working Environment | 0℃~50℃,<0.2MPa |
Answers to the questions that the recorded characteristics of FT-S15S can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Output mode": RS-485 (ModbusRTU protocol).
Yes — recorded under "Self-cleaning function": Equipped with an automatic cleaner to prevent biological adhesion and light window pollution to ensure long-term monitoring stability; the automatic cleaning time and cleaning frequency can be set, and the power consumption is 0.7W.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Chlorophyll a fluorescence sensor with automatic self-cleaning

Online COD Analyzer

Drinking Water Monitoring

Online Chloride Ion Meter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | FT-S15S |
| Manufacturer | Fengtu |
pH and Conductivity Analyzers
RS485 Modbus Dissolved Oxygen Sensor, Fluorescence Method
Price on request
pH and Conductivity Analyzers
Online UV fluorescence BOD sensor, reagent-free · Ref. : WQ-BOD-4S
Price on request
pH and Conductivity Analyzers
Portable ORP analyzer with digital electrode and touch screen · Ref. : ORP-METER
Price on request
pH and Conductivity Analyzers
Multiparameter Water Quality Sensor · Ref. : KPS-400
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details