Industrial online residual chlorine sensor with automatic temperature compensation, for continuous monitoring of residual chlorine in aqueous solutions.
Supply voltage12-24VDC (0.3W@12V)
Accuracy±0.1PH; ±0.3℃
Cable LengthStandard 5 meters
CommunicationRS485(MODBUS-RTU)
InstallationFlow cell installation, 3/4NPT
pH compensationAutomatic pH compensation
Product overview
Fengtu FT-S4. Online residual chlorine sensor based on an industrial residual chlorine electrode, designed for continuous measurement of residual chlorine content in aqueous solutions.
Main characteristics. The sensor includes a built-in temperature sensor with automatic temperature compensation and automatic pH compensation. It has an integrated structure that is easy to install, an ABS shell and an IP68 waterproof grade. Range and resolution of 0 to 14 pH, with accuracy of ±0.1 pH and ±0.3 ℃.
Interfaces and connectivity. RS485 output using the MODBUS-RTU protocol. The standard cable is 5 meters long and consists of a 4-core twisted pair shielded cable, with red power line, black ground wire, blue 485A and green 485B.
Power and environment. Power supply of 12 to 24 VDC, 0.3 W at 12 V. Flow cell installation with 3/4NPT connection.
Typical uses. Drinking water treatment plants, bottling plants, drinking water distribution networks, swimming pools, cooling water circulation and water quality treatment projects where residual chlorine content must be continuously monitored.
Integration. The sensor must be mounted in the matching flow cell, with the measuring part placed near the water inlet, at a recommended flow rate of 30 to 60 L/h. Wiring should be checked before power-on. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for RESIDUAL-CHLORINE-SENSOR, with where it comes from. Use the filters to find one quickly.
All specifications (13)
Characteristic
Value
Supply voltage
12-24VDC (0.3W@12V)
Accuracy
±0.1PH; ±0.3℃
Cable Length
Standard 5 meters
Communication
RS485(MODBUS-RTU)
Installation
Flow cell installation, 3/4NPT
pH compensation
Automatic pH compensation
Photovoltaic Weather Stations
Collecting Environmental Data to Support the Stable Operation of Distributed PV Power Plants
Range and resolution
0~14(PH)
Residual Chlorine Sensor
Residual Chlorine Sensor
Shell material
ABS
Temperature Compensation
Automatic temperature compensation
Water PH Sensor
Selection, Installation, and Maintenance
Waterproof Grade
IP68
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for RESIDUAL-CHLORINE-SENSOR. For a missing document or a specific revision, our experts send it to you.
Industrial online residual chlorine sensor with automatic temperature compensation, for continuous monitoring of residual chlorine in aqueous solutions.
Supply voltage12-24VDC (0.3W@12V)
Accuracy±0.1PH; ±0.3℃
Cable LengthStandard 5 meters
CommunicationRS485(MODBUS-RTU)
InstallationFlow cell installation, 3/4NPT
2. Datasheet extract (recorded values)
Parameter
Value
Supply voltage
12-24VDC (0.3W@12V)
Accuracy
±0.1PH; ±0.3℃
Cable Length
Standard 5 meters
Communication
RS485(MODBUS-RTU)
Installation
Flow cell installation, 3/4NPT
pH compensation
Automatic pH compensation
Photovoltaic Weather Stations
Collecting Environmental Data to Support the Stable Operation of Distributed PV Power Plants
Range and resolution
0~14(PH)
Residual Chlorine Sensor
Residual Chlorine Sensor
Shell material
ABS
Temperature Compensation
Automatic temperature compensation
Water PH Sensor
Selection, Installation, and Maintenance
Waterproof Grade
IP68
Integration
Points to check before using RESIDUAL-CHLORINE-SENSOR in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with 12-24VDC (0.3W@12V).
Power and communication
Supply voltage
12-24VDC (0.3W@12V)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with 12-24VDC (0.3W@12V).
Applications and use cases
Architectures in which RESIDUAL-CHLORINE-SENSOR can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for RESIDUAL-CHLORINE-SENSOR and the other parts of your project.
Answers to the questions that the recorded characteristics of RESIDUAL-CHLORINE-SENSOR can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Communication": RS485(MODBUS-RTU).
2Does it support Modbus?
Yes — recorded under "Communication": RS485(MODBUS-RTU).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details