FT-S2 – RS485 Modbus RTU Water Hardness Sensor

RS485 Modbus RTU Water Hardness Sensor

Water Quality Analyzers and Probes

  • 0~1000mg/L (as Ca)
  • 12-24VDC (0.4W@12V)
  • Standard 5 meters
  • ABS
Manufacturer part number
WATER-HARDNESS-METER
Manufacturer
Fengtu
Supply voltage
12-24VDC (0.4W@12V)
Cable Length
Standard 5 meters

The Fengtu FT-S2 water hardness sensor measures the calcium and magnesium ion concentration in water and outputs hardness over RS485 MODBUS-RTU for online water quality monitoring.

Product overview

Fengtu FT-S2 water hardness sensor. the Fengtu FT-S2 is a water hardness sensor designed for online water quality monitoring in industrial and environmental applications.

Measurement principle. The sensor uses an indirect contact electrode method: it measures the conductivity of the water sample and converts this reading into a water hardness value expressed in mg/L (as Ca), based on a pre-calibrated correlation between conductivity and hardness.

Main characteristics. Hardness measurement range of 0 to 1000 mg/L (as Ca), resolution of 0.1 mg/L and accuracy of ±10% for hardness, with ±0.1°C accuracy for temperature. Response time is approximately 30 s (98% in static liquid).

Connectivity and signal. The output is an RS485 link with MODBUS-RTU protocol. Internal signal isolation ensures strong interference immunity.

Power and environment. Supply of 12 to 24 VDC (0.4 W at 12 V). Measurement environment of 0 to 50°C (non-freezing) and below 0.2 MPa. ABS casing, IP68 waterproof rating, standard cable length of 5 meters.

Installation. In-line installation with NPT 3/4 thread, suitable for submersion or mounting on pipelines and tanks.

Maintenance. Standard electrodes require periodic cleaning and calibration, with zero-point and slope calibration using standard solutions of 0 to 100 mg/L and then 100 to 1000 mg/L.

The product is available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Supply voltage: 12-24VDC (0.4W@12V)
  • Response time: Approx. 30s (98% static liquid)
  • Cable Length: Standard 5 meters
  • Casing material: ABS
  • Installation Method: In-line installation, NPT3/4 thread
  • Measurement environment: Temperature 0~50℃ (non-freezing), <0.2MPa