Modular DIN-rail remote I/O coupler linking a CAN bus or Modbus network to distributed terminal I/O modules, with up to 32 I/O modules.
CAN — interfaceone open 4 terminal
Starting Currentabout 2.5 times continuous current
Baud rate10Kbps~1000Kbps
Data Rate100Mbps
Dimension100mm*69mm*48mm
Distance100m
Product overview
Overview. The GCAN-IO-8000 is a GCAN remote I/O coupler on DIN rail that connects a CAN bus system to distributed bus terminal I/O modules, expandable in a modular way. A complete node consists of a coupler, 1 to 32 I/O modules and a terminal module.
Main characteristics. The coupler accepts up to 32 I/O modules, for a maximum of 32 × 8 I/O points. It supports node numbers 1 to 127 and a configurable baud rate from 10 Kbps to 1000 Kbps. It supports CANopen communication in accordance with ISO 11898 and offers automatic configuration, with no parameter setting on a PC. The firmware can be upgraded through the interface.
Interfaces and connectivity. The coupler provides one open 4-terminal CAN interface and an RS-232 interface for configuring the baud rate. It supports Modbus function codes 01, 02, 03, 04, 05, 06, 15 and 16. The data rate is 100 Mbps and the distance is 100 m.
Power and environment. The power input is 24 V DC (18 to 36 V). The power contacts handle a maximum of 24 V DC and 10 A. The starting current is about 2.5 times the continuous current. Electrical isolation is 1500 Vrms. The housing measures 100 mm × 69 mm × 48 mm, with IP20 protection. The operating range is -40 °C to +85 °C at 0 to 90 % RH, without condensation.
Typical uses. Decentralized data acquisition and remote I/O control on a CANopen or Modbus network.
Integration. The GCAN-IO-8000 mounts on a DIN rail and connects to distributed terminal modules to form a complete control node.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for IO-COUPLER, with where it comes from. Use the filters to find one quickly.
All specifications (15)
Characteristic
Value
Baud rate
10Kbps~1000Kbps
CAN — interface
one open 4 terminal
Data Rate
100Mbps
Dimension
100mm*69mm*48mm
Distance
100m
Electrical isolation
1500 Vrms
Insert I/O module number
32 pieces (at most 32*8 IO point)
IP Grade
IP20
Module feature
Connect with distributed bus terminal modules to form a complete control node; Perform data acquisition and data transfer with EtherCAT protocol.; Power contacts: maximum 24V DC/maximum 10A; Electrical isolation: 1500 Vrms
Node number
1~127
Power contacts
maximum 24V DC/maximum 10A
Power Input
24V DC (18~36V)
Starting Current
about 2.5 times continuous current
Support Modbus function code
01, 02, 03, 04, 05, 06, 15, 16
Working temperature, humdidness
-40℃~+85℃, 0~90%RH, without condensation
No specification matches.
Last verification : 2026-11-03
Technical documentation
Official documents and the technical data recorded for IO-COUPLER. For a missing document or a specific revision, our experts send it to you.
Modular DIN-rail remote I/O coupler linking a CAN bus or Modbus network to distributed terminal I/O modules, with up to 32 I/O modules.
CAN — interfaceone open 4 terminal
Starting Currentabout 2.5 times continuous current
Baud rate10Kbps~1000Kbps
Data Rate100Mbps
Dimension100mm*69mm*48mm
2. Datasheet extract (recorded values)
Parameter
Value
Baud rate
10Kbps~1000Kbps
CAN — interface
one open 4 terminal
Data Rate
100Mbps
Dimension
100mm*69mm*48mm
Distance
100m
Electrical isolation
1500 Vrms
Insert I/O module number
32 pieces (at most 32*8 IO point)
IP Grade
IP20
Module feature
Connect with distributed bus terminal modules to form a complete control node; Perform data acquisition and data transfer with EtherCAT protocol.; Power contacts: maximum 24V DC/maximum 10A; Electrical isolation: 1500 Vrms
Node number
1~127
Power contacts
maximum 24V DC/maximum 10A
Power Input
24V DC (18~36V)
Starting Current
about 2.5 times continuous current
Support Modbus function code
01, 02, 03, 04, 05, 06, 15, 16
Working temperature, humdidness
-40℃~+85℃, 0~90%RH, without condensation
Applications and use cases
Architectures in which IO-COUPLER can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
A proprietary PLC locks the project into one vendor’s tools. Industrial controllers built on the Raspberry Pi Compute Module run Linux, Node-RED, Python or CODESYS on DIN rail, with I/O modules, an operator panel and a cellular router for remote access
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productGCAN
IO-COUPLER
CANopen and Modbus remote I/O coupler for DIN rail
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details