GH3300 – Multimodal analog front end for PPG, ECG and bio-impedance

Multimodal analog front end for PPG, ECG and bio-impedance

Medical Sensors

  • IIC/SPI
  • WLCSP-49
  • 24-bit
  • 1.25 μVrms @ 20 * gain
Manufacturer part number
GH3300
Manufacturer
Goodix
Interface
IIC/SPI
Package
WLCSP-49

The Goodix GH3300 is an ultra-low-power multimodal analog front end for PPG, ECG and bio-impedance measurement in medical devices and high-end smartwatches.

Product overview

Overview. The Goodix GH3300 is an ultra-low-power, ultra-high-precision and multi-modal analog front end (AFE) capable of PPG, ECG and Bio-Z (BIA, IPG and EDA) measurement. Its flexible operating mode lets the AFE accommodate various sensors, including temperature sensors.

PPG signal chain. Four independent PPG channels with simultaneous sampling, supporting 8 single-ended or 4 differential photodiode inputs, four 24-bit ADCs and four LED drivers of 200 mA peak current each, for up to 16 LEDs. Dark current noise is below 14 pArms.

ECG signal chain. One channel in DC or AC mode adapted to 1-lead ECG acquisition. RTI noise is 1.67 μVrms in DC mode at gain 1 and 1.25 μVrms in AC mode at gain 20. ECG input impedance of 10 GΩ and DC input range of ±1300 mV for dry electrode applications.

Impedance measurement chain. Programmable BIA TX current excitation source up to 1 MHz, ultra-low-noise INA with high pass filter, four-electrode impedance measurement and a built-in analog I/Q demodulator providing complex (I, Q) impedance data. Magnitude accuracy ±0.1% and phase angle accuracy ±0.1°.

Interfaces and memory. IIC/SPI interface, 96k bytes FIFO including 16 k bytes (3200 samples) internal FIFO area 1 and 80 k bytes (16 k samples) area 2. WLCSP-49 package, chip size 2.645 × 2.645 × 0.5 mm.

Typical uses. Medical electronics such as multi-parameter monitors and hand-held ECG monitors, and consumer electronics such as wearable devices. Temperature measurement with ±0.1 °C accuracy from 25 °C to 45 °C.

Algorithms. The GH3300 supports heart rate (HR), SpO2, heart rate variability (HRV), ECG, BIA and wear detection algorithms.

See all specifications

Highlights

  • Analog-to-digital converter: 24-bit
  • Package: WLCSP-49
  • AC mode RTI noise: 1.25 μVrms @ 20 * gain
  • Algorithm: HR, SpO2, HRV, ECG, BIA, Wear Detect
  • Area 2: 80 k bytes(16 k samples)
  • Chip Size (mm): 2.645 * 2.645 * 0.5