GH3300 – Multimodal analog front end for PPG, ECG and bio-impedance
Multimodal analog front end for PPG, ECG and bio-impedance
- IIC/SPI
- WLCSP-49
- 24-bit
- 1.25 μVrms @ 20 * gain
- Manufacturer part number
- GH3300
- Manufacturer
- Goodix
- Interface
- IIC/SPI
- Package
- WLCSP-49
The Goodix GH3300 is an ultra-low-power multimodal analog front end for PPG, ECG and bio-impedance measurement in medical devices and high-end smartwatches.
- InterfaceIIC/SPI
- PackageWLCSP-49
- Analog-to-digital converter24-bit
- AC mode RTI noise1.25 μVrms @ 20 * gain
- AlgorithmHR, SpO2, HRV, ECG, BIA, Wear Detect
- Area 280 k bytes(16 k samples)
Product overview
Overview. The Goodix GH3300 is an ultra-low-power, ultra-high-precision and multi-modal analog front end (AFE) capable of PPG, ECG and Bio-Z (BIA, IPG and EDA) measurement. Its flexible operating mode lets the AFE accommodate various sensors, including temperature sensors.
PPG signal chain. Four independent PPG channels with simultaneous sampling, supporting 8 single-ended or 4 differential photodiode inputs, four 24-bit ADCs and four LED drivers of 200 mA peak current each, for up to 16 LEDs. Dark current noise is below 14 pArms.
ECG signal chain. One channel in DC or AC mode adapted to 1-lead ECG acquisition. RTI noise is 1.67 μVrms in DC mode at gain 1 and 1.25 μVrms in AC mode at gain 20. ECG input impedance of 10 GΩ and DC input range of ±1300 mV for dry electrode applications.
Impedance measurement chain. Programmable BIA TX current excitation source up to 1 MHz, ultra-low-noise INA with high pass filter, four-electrode impedance measurement and a built-in analog I/Q demodulator providing complex (I, Q) impedance data. Magnitude accuracy ±0.1% and phase angle accuracy ±0.1°.
Interfaces and memory. IIC/SPI interface, 96k bytes FIFO including 16 k bytes (3200 samples) internal FIFO area 1 and 80 k bytes (16 k samples) area 2. WLCSP-49 package, chip size 2.645 × 2.645 × 0.5 mm.
Typical uses. Medical electronics such as multi-parameter monitors and hand-held ECG monitors, and consumer electronics such as wearable devices. Temperature measurement with ±0.1 °C accuracy from 25 °C to 45 °C.
Algorithms. The GH3300 supports heart rate (HR), SpO2, heart rate variability (HRV), ECG, BIA and wear detection algorithms.
Highlights
- Analog-to-digital converter: 24-bit
- Package: WLCSP-49
- AC mode RTI noise: 1.25 μVrms @ 20 * gain
- Algorithm: HR, SpO2, HRV, ECG, BIA, Wear Detect
- Area 2: 80 k bytes(16 k samples)
- Chip Size (mm): 2.645 * 2.645 * 0.5
Technical questions
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for GH3300, with where it comes from. Use the filters to find one quickly.
All specifications (18)
| Characteristic | Value |
|---|---|
| Analog-to-digital converter | 24-bit |
| Package | WLCSP-49 |
| AC mode RTI noise | 1.25 μVrms @ 20 * gain |
| Algorithm | HR, SpO2, HRV, ECG, BIA, Wear Detect |
| Area 2 | 80 k bytes(16 k samples) |
| Bio-Z | Magnitude:±0.1%; Phase angle:±0.1° |
| Chip Size (mm) | 2.645 * 2.645 * 0.5 |
| DC mode RTI noise | 1.67 μVrms @ 1 * gain |
| ECG | 1 (DC or AC) |
| FIFO | 96k bytes |
| Interface | IIC/SPI |
| Internal FIFO Area 1 | 16 k bytes (3200 samples) |
| Medical electronics | multi parameter monitor, hand-held ECG monitor |
| PPG RX | 8 Single/4 Diff |
| PPG TX | 200 mA * 4 |
| Pressure | / |
| Temperature | ±0.1 °C@25 °C ~ 45 °C |
| Typical Applications Consumer electronics | wearable devices |
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for GH3300. For a missing document or a specific revision, our experts send it to you.
Contents
Overview Datasheet extract Official documents1. Technical overview
The Goodix GH3300 is an ultra-low-power multimodal analog front end for PPG, ECG and bio-impedance measurement in medical devices and high-end smartwatches.
2. Datasheet extract (recorded values)
| Parameter | Value |
|---|---|
| Analog-to-digital converter | 24-bit |
| Package | WLCSP-49 |
| AC mode RTI noise | 1.25 μVrms @ 20 * gain |
| Algorithm | HR, SpO2, HRV, ECG, BIA, Wear Detect |
| Area 2 | 80 k bytes(16 k samples) |
| Bio-Z | Magnitude:±0.1%; Phase angle:±0.1° |
| Chip Size (mm) | 2.645 * 2.645 * 0.5 |
| DC mode RTI noise | 1.67 μVrms @ 1 * gain |
| ECG | 1 (DC or AC) |
| FIFO | 96k bytes |
| Interface | IIC/SPI |
| Internal FIFO Area 1 | 16 k bytes (3200 samples) |
| Medical electronics | multi parameter monitor, hand-held ECG monitor |
| PPG RX | 8 Single/4 Diff |
| PPG TX | 200 mA * 4 |
| Pressure | / |
| Temperature | ±0.1 °C@25 °C ~ 45 °C |
| Typical Applications Consumer electronics | wearable devices |
Technical FAQ
Answers to the questions that the recorded characteristics of GH3300 can answer. A question is not asked when nothing is recorded to answer it.
1Does it support SPI?
Yes — recorded under "Interface": IIC/SPI.
Compliance, lifecycle and traceability
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
Lifecycle and product statusStatus not stated
- In production
- Not recommended for new designs
- End of life
- Obsolete
| Current status | Status not stated |
| Key dates | Not recorded |
Manufacturer references
| Manufacturer part number | GH3300 |
| Manufacturer | Goodix |