S10500X
Multiservice Core Switch, Modular Chassis

- Input Voltage
- AC:100V~240V; DC:-48V~-60V
- Maximum power consumption — 4580W — 6270W
- 7670W
- MPU flash /SDRAM
- Flash 2GB; SDRAM 8GB
- Hardware Architecture
- Orthogonal CLOS
Multiservice Core Switch, Modular Chassis
H3C S10500X multiservice core switch for data center core layers, next-generation campus networks and metropolitan area network distribution layers.
H3C S10500X Multiservice Core Switch. The H3C S10500X multiservice core switch is a modular switch of the S10500X series, designed for the core layer of data centers and next-generation campus networks, as well as the distribution layer of metropolitan area networks.
Architecture. The system uses an orthogonal CLOS multistage and multi-plane switching architecture with a switching capacity of up to 100 Tbps and a forwarding capacity of 18000 to 30000 Mpps depending on the configuration. Switching fabric modules and service modules are interconnected orthogonally, without cabling on the backplane.
Redundancy. Redundant MPUs, switching fabric modules, power modules and fan trays, with five switching fabric module slots (two integrated in the MPU).
QoS and security. Standard and extended ACLs, ingress and egress ACLs, VLAN ACLs, ingress and egress CAR with 8K granularity, Diff-Serv, 802.1P/DSCP marking and remarking, SP, WRR, SP+WRR and WFQ queue scheduling, traffic shaping, WRED. 802.1x authentication, AAA/Radius, HWTACACS, SSHv2, uRPF.
Connectivity and routing. MPLS/VPLS support, L3 MPLS VPN, VXLAN with MP-BGP+EVPN distributed control plane, multicast with PIM-DM, PIM-SM, PIM-SSM, IGMP and MLD snooping, OpenFlow 1.3.
Management and automation. Telemetry, IEEE 1588V2, SNMP v1/v2/v3, sFlow, RMON, NTP, programmability with Ansible and RESTful APIs, NETCONF and Python for automated network programming.
Integration. AC input 100V to 240V or DC input -48V to -60V, operating temperature 0°C to 45°C, compliant with CISPR 32 Class A EMC standards and IEC 60950-1 safety standard.”
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for S10500X, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| ACL/QoS | Standard and extended ACLs; Ingress and Egress ACL; VLAN ACL; Global ACL; Ingress/Egress CAR with 8K granularity; Diff-Serv QoS; 802.1P/DSCP Priority marking and remarking; 802.1p, TOS, DSCP, and EXP priority mapping; Flexible queue scheduling algorithms including SP, WRR, SP+WRR, WFQ; Traffic shaping; Congestion avoidance, Tail-Drop and WRED |
| Dimension (H x W x D)/mm — 397×440×660; 9RU — 620×440×660; 14RU | 664×440×660; 15RU |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 24; EN 55024; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386 |
| Forwarding capacity — 18000Mpps — 24000Mpps | 30000Mpps |
| Fully loaded weight — < 85 kg; < 187.4 lb — < 120 kg; < 264.6 lb | < 130 kg; < 286.6 lb |
| Green | IEEE (802.3az) |
| Hardware Architecture | Orthogonal CLOS |
| Input Voltage | AC:100V~240V; DC:-48V~-60V |
| LS-10506X | H3C S10506X Ethernet Switch Chassis |
| LS-10508X | H3C S10508X Ethernet Switch Chassis |
| LS-10510X | H3C S10510X Ethernet Switch Chassis |
| LSUM1AC2500 | AC Power Supply Module,2500W |
| LSUM1CGS2FE0 | H3C S10500 2-Port 100G Ethernet Optical Interface Module(QSFP28)(FE) |
| LSUM1CGS8QSSH0 | H3C S10500 8-Port 100G Ethernet Optical Interface(QSFP28) +8-Port 40G/4-Port 100G Ethernet Optical Interface Module(QSFP28)(SH) |
| LSUM1CGS8SH0 | H3C S10500 8-Port 100G Ethernet Optical Interface Module(QSFP28)(SH) |
| LSUM1DC2400 | DC Power Supply Module,2400W |
| LSUM1FAB06XEC0 | H3C S10506X Fabric Module, Type EC |
| LSUM1FAB08XE0 | H3C S10508X&S10508X-V Fabric Module, Type E |
| LSUM1FAB10XE0 | H3C S10510X Fabric Module, Type E |
| LSUM1GP48FD0 | H3C S10500 48-Port 1000BASE Ethernet Optical Interface Module(SFP,LC)(FD) |
| LSUM1GT48FD0 | H3C S10500 48-Port 1000BASE-T Ethernet Copper Interface Module(RJ45)(FD) |
| LSUM1MPUS06XEC0 | H3C S10506X Main Processing Unit with Switching, Type EC |
| LSUM1MPUS10XE0 | H3C S10510X Main Processing Unit with Switching, Type E |
| LSUM1SUPXD0 | H3C S10500X Supervisor Engine Unit, Type D |
| LSUM1TGS16FD0 | H3C S10500 16-Port 10G Ethernet Optical Interface Module(SFP+,LC)(FD) |
| LSUM1TGS24CSSH0 | H3C S10500 24-Port 10G Ethernet Optical Interface (SFP+) + 4-Port 100G Ethernet Optical Interface Module (QSFP28)(SH) |
| LSUM1TGS24FD0 | H3C S10500 24-Port 10G Ethernet Optical Interface Module(SFP+,LC)(FD) |
| LSUM1TGT24FD0 | H3C S10500 24-Port 10GBASE-T Ethernet Copper Interface Module(RJ45)(FD) |
| LSUM1YGS24CSSH0 | H3C S10500 24-Port 25G Ethernet Optical Interface(SFP28,LC)+4-Port 100G Ethernet Optical Interface Module(QSFP28)(SH) |
| LSUM2CQGS12SG0 | H3C S10500 12-Port 40G/4-Port 100G Ethernet Optical Interface Module(QSFP28)(SG) |
| LSUM2GT24PTSSE0 | 24-Port 10/100/1000BASE-T Interface(RJ45)+20-Port GE Optical Interface(SFP,LC)+4-Port 10GE Optical Interface Module(SFP+,LC) |
| LSUM2QGS12SG0 | H3C S10500,12-Port 40GBASE Ethernet Optical Interface Module(QSFP+)(SG) |
| LSUM2QGS24RSG0 | H3C S10500 24-Port 40G Ethernet Optical Interface Module(QSFP+)(SG) |
| LSUM2TGS32QSSG0 | H3C S10500,32-Port 10Gb Ethernet Optical Interface(SFP+,LC)+4-Port 40Gb Ethernet Optical Interface Module(QSFP+)(SG) |
| LSUM2TGS48SH0 | H3C S10500 48-Port 10G Ethernet Optical Interface Module (SFP+,LC)(SH) |
| Maximum power consumption — 4580W — 6270W | 7670W |
| MPLS/VPLS | L3 MPLS VPN; L2 VPN: VLL (Martini, Kompella); MCE; MPLS OAM; VPLS, VLL; Hierarchy VPLS, QinQ+VPLS; P/PE function; LDP |
| MPU console ports | 1x RJ-45; 1x USB console |
| MPU flash /SDRAM | Flash 2GB; SDRAM 8GB |
| MPU MGMT ports | 2x 10/100/1000M RJ-45; 2x 1000M SFP |
| MPU name — LSUM1MPUS06XEC0 — LSUM1SUPXD0 | LSUM1MPUS10XE0 |
| MPU processor — 1.8GHz 4 cores — 1.2GHz 4 cores | 1.8GHz 4 cores |
| MTBF(Year) — 24.83 — 27.05 | 24.58 |
| MTTR [hour] | 0.5 |
| Multicast | PIM-DM, PIM-SM, PIM-SSM, MSDP, MBGP, and Any-RP; IGMP V1/V2/V3\IGMP V1/V2/V3 Snooping; IGMP Filter and IGMP Fast leave; PIM6-DM\PIM6-SM\PIM6-SSM; MLD V1/V2\MLD V1/V2 Snooping; Multicast policy and Multicast QoS; Max. 16K IPV4 multicast routing entries; Max. 8K IPV6 multicast routing entries |
| O&M | Telemetry; IEEE 1588V2 |
| Operating Environment | Temperature: 0ºC to 45ºC (32°F to 113°F); Humidity: 5% to 95% (non-condensing) |
| Product ID | Product Description |
| Programmability and Automation | Ansible; Auto DevOps by using Python, NETCONF, TCL, and Restful APIs for automated network programming |
| Redundancy | Redundant MPUs, switching fabric modules, power modules, and fan trays |
| Safety | UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1; EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| SDN/OPENFLOW | OpenFlow 1.3; Multiple controllers (EQUAL, master/slave); Multiple tables flow; Group table; Meter |
| Security | Hierarchical user management and password protection; EAD; Portal authentication; MAC authentication; IEEE 802.1x and IEEE 802.1x SERVER; AAA/Radius; HWTACACS; SSHv1.5/SSHv2; Basic and advanced ACLs for packet filtering; OSPF, RIPv2, BGPv4 plain text and MD5 authentication; IP address, VLAN ID, MAC address multiple binding combination; uRPF; Active/standby data backup |
| Switching capacity — 60Tbps — 80Tbps | 100Tbps |
| Switching fabric module slots — 5(2 integrated in MPU) — 5 | 5(2 integrated in MPU) |
| System management | IMC network management system; Loading and upgrading through XModem/FTP/TFTP; SNMP v1/v2/v3; sFlow; RMON and groups 1,2,3 and 9; NTP clocks; Fault alarm and automatic fault recovery; System logs; Device status monitoring mechanism, including the CPU engine, backplane, chips and other key components |
| VXLAN | VXLAN L2 switching; VXLAN L3 routing; VXLAN VTEP; IS-IS+ENDP distributed control plane; MP-BGP+EVPN distributed control plane; OpenFlow+Netconf centralized control plane |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for S10500X. For a missing document or a specific revision, our experts send it to you.
H3C S10500X multiservice core switch for data center core layers, next-generation campus networks and metropolitan area network distribution layers.
| Parameter | Value |
|---|---|
| ACL/QoS | Standard and extended ACLs; Ingress and Egress ACL; VLAN ACL; Global ACL; Ingress/Egress CAR with 8K granularity; Diff-Serv QoS; 802.1P/DSCP Priority marking and remarking; 802.1p, TOS, DSCP, and EXP priority mapping; Flexible queue scheduling algorithms including SP, WRR, SP+WRR, WFQ; Traffic shaping; Congestion avoidance, Tail-Drop and WRED |
| Dimension (H x W x D)/mm — 397×440×660; 9RU — 620×440×660; 14RU | 664×440×660; 15RU |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 24; EN 55024; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386 |
| Forwarding capacity — 18000Mpps — 24000Mpps | 30000Mpps |
| Fully loaded weight — < 85 kg; < 187.4 lb — < 120 kg; < 264.6 lb | < 130 kg; < 286.6 lb |
| Green | IEEE (802.3az) |
| Hardware Architecture | Orthogonal CLOS |
| Input Voltage | AC:100V~240V; DC:-48V~-60V |
| LS-10506X | H3C S10506X Ethernet Switch Chassis |
| LS-10508X | H3C S10508X Ethernet Switch Chassis |
| LS-10510X | H3C S10510X Ethernet Switch Chassis |
| LSUM1AC2500 | AC Power Supply Module,2500W |
| LSUM1CGS2FE0 | H3C S10500 2-Port 100G Ethernet Optical Interface Module(QSFP28)(FE) |
| LSUM1CGS8QSSH0 | H3C S10500 8-Port 100G Ethernet Optical Interface(QSFP28) +8-Port 40G/4-Port 100G Ethernet Optical Interface Module(QSFP28)(SH) |
| LSUM1CGS8SH0 | H3C S10500 8-Port 100G Ethernet Optical Interface Module(QSFP28)(SH) |
| LSUM1DC2400 | DC Power Supply Module,2400W |
| LSUM1FAB06XEC0 | H3C S10506X Fabric Module, Type EC |
| LSUM1FAB08XE0 | H3C S10508X&S10508X-V Fabric Module, Type E |
| LSUM1FAB10XE0 | H3C S10510X Fabric Module, Type E |
| LSUM1GP48FD0 | H3C S10500 48-Port 1000BASE Ethernet Optical Interface Module(SFP,LC)(FD) |
| LSUM1GT48FD0 | H3C S10500 48-Port 1000BASE-T Ethernet Copper Interface Module(RJ45)(FD) |
| LSUM1MPUS06XEC0 | H3C S10506X Main Processing Unit with Switching, Type EC |
| LSUM1MPUS10XE0 | H3C S10510X Main Processing Unit with Switching, Type E |
| LSUM1SUPXD0 | H3C S10500X Supervisor Engine Unit, Type D |
| LSUM1TGS16FD0 | H3C S10500 16-Port 10G Ethernet Optical Interface Module(SFP+,LC)(FD) |
| LSUM1TGS24CSSH0 | H3C S10500 24-Port 10G Ethernet Optical Interface (SFP+) + 4-Port 100G Ethernet Optical Interface Module (QSFP28)(SH) |
| LSUM1TGS24FD0 | H3C S10500 24-Port 10G Ethernet Optical Interface Module(SFP+,LC)(FD) |
| LSUM1TGT24FD0 | H3C S10500 24-Port 10GBASE-T Ethernet Copper Interface Module(RJ45)(FD) |
| LSUM1YGS24CSSH0 | H3C S10500 24-Port 25G Ethernet Optical Interface(SFP28,LC)+4-Port 100G Ethernet Optical Interface Module(QSFP28)(SH) |
| LSUM2CQGS12SG0 | H3C S10500 12-Port 40G/4-Port 100G Ethernet Optical Interface Module(QSFP28)(SG) |
| LSUM2GT24PTSSE0 | 24-Port 10/100/1000BASE-T Interface(RJ45)+20-Port GE Optical Interface(SFP,LC)+4-Port 10GE Optical Interface Module(SFP+,LC) |
| LSUM2QGS12SG0 | H3C S10500,12-Port 40GBASE Ethernet Optical Interface Module(QSFP+)(SG) |
| LSUM2QGS24RSG0 | H3C S10500 24-Port 40G Ethernet Optical Interface Module(QSFP+)(SG) |
| LSUM2TGS32QSSG0 | H3C S10500,32-Port 10Gb Ethernet Optical Interface(SFP+,LC)+4-Port 40Gb Ethernet Optical Interface Module(QSFP+)(SG) |
| LSUM2TGS48SH0 | H3C S10500 48-Port 10G Ethernet Optical Interface Module (SFP+,LC)(SH) |
| Maximum power consumption — 4580W — 6270W | 7670W |
| MPLS/VPLS | L3 MPLS VPN; L2 VPN: VLL (Martini, Kompella); MCE; MPLS OAM; VPLS, VLL; Hierarchy VPLS, QinQ+VPLS; P/PE function; LDP |
| MPU console ports | 1x RJ-45; 1x USB console |
| MPU flash /SDRAM | Flash 2GB; SDRAM 8GB |
| MPU MGMT ports | 2x 10/100/1000M RJ-45; 2x 1000M SFP |
| MPU name — LSUM1MPUS06XEC0 — LSUM1SUPXD0 | LSUM1MPUS10XE0 |
| MPU processor — 1.8GHz 4 cores — 1.2GHz 4 cores | 1.8GHz 4 cores |
| MTBF(Year) — 24.83 — 27.05 | 24.58 |
| MTTR [hour] | 0.5 |
| Multicast | PIM-DM, PIM-SM, PIM-SSM, MSDP, MBGP, and Any-RP; IGMP V1/V2/V3\IGMP V1/V2/V3 Snooping; IGMP Filter and IGMP Fast leave; PIM6-DM\PIM6-SM\PIM6-SSM; MLD V1/V2\MLD V1/V2 Snooping; Multicast policy and Multicast QoS; Max. 16K IPV4 multicast routing entries; Max. 8K IPV6 multicast routing entries |
| O&M | Telemetry; IEEE 1588V2 |
| Operating Environment | Temperature: 0ºC to 45ºC (32°F to 113°F); Humidity: 5% to 95% (non-condensing) |
| Product ID | Product Description |
| Programmability and Automation | Ansible; Auto DevOps by using Python, NETCONF, TCL, and Restful APIs for automated network programming |
| Redundancy | Redundant MPUs, switching fabric modules, power modules, and fan trays |
| Safety | UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1; EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| SDN/OPENFLOW | OpenFlow 1.3; Multiple controllers (EQUAL, master/slave); Multiple tables flow; Group table; Meter |
| Security | Hierarchical user management and password protection; EAD; Portal authentication; MAC authentication; IEEE 802.1x and IEEE 802.1x SERVER; AAA/Radius; HWTACACS; SSHv1.5/SSHv2; Basic and advanced ACLs for packet filtering; OSPF, RIPv2, BGPv4 plain text and MD5 authentication; IP address, VLAN ID, MAC address multiple binding combination; uRPF; Active/standby data backup |
| Switching capacity — 60Tbps — 80Tbps | 100Tbps |
| Switching fabric module slots — 5(2 integrated in MPU) — 5 | 5(2 integrated in MPU) |
| System management | IMC network management system; Loading and upgrading through XModem/FTP/TFTP; SNMP v1/v2/v3; sFlow; RMON and groups 1,2,3 and 9; NTP clocks; Fault alarm and automatic fault recovery; System logs; Device status monitoring mechanism, including the CPU engine, backplane, chips and other key components |
| VXLAN | VXLAN L2 switching; VXLAN L3 routing; VXLAN VTEP; IS-IS+ENDP distributed control plane; MP-BGP+EVPN distributed control plane; OpenFlow+Netconf centralized control plane |
Answers to the questions that the recorded characteristics of S10500X can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Safety": UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1; EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1.
Yes — recorded under "LS-10506X": H3C S10506X Ethernet Switch Chassis.
Yes — recorded under "MPU console ports": 1x RJ-45; 1x USB console.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Multiservice Core Switch, Modular Chassis

30 Port SFP+ Layer 3 Managed Industrial Ethernet Switch

Layer 3 10GBASE-X SFP+ + 4-Port 10GBASE-T Managed Ethernet Switch

L3 100/1G SFP with 4 shared 10/100/1000T + 10-Port 1G/2.5G SFP + 4-Port 10G SFP+ Metro Ethernet Switch

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | S10500X |
| Manufacturer | H3C |
Core and Aggregation Switches
Gigabit Managed Layer 3 Switch with 4 SFP Ports · Ref. : DGS-3312SR
Price on request
Core and Aggregation Switches
24-port Layer 3 PoE+ switch with 2.5 GbE and 10G SFP+ · Ref. : USW-ENTERPRISE-24-POE
Price on request
Core and Aggregation Switches
IP65 high bay dual sense presence sensor HF and PIR · Ref. : HIM30-B-L2
Price on request
Core and Aggregation Switches
28-port GbE L3 aggregation switch with 4 SFP+ uplinks
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details