S5000NV6-EI
Gigabit managed PoE+ access switch for campus networks

- Power consumption (static); Data collection standard: no load
- 7 W
- Flash
- 256MB
- Operating/Storage Humidity
- 5% RH to 95% RH, non-condensing
- SDRAM
- 1G
Gigabit managed PoE+ access switch for campus networks
The H3C S5000NV6-EI is a Gigabit managed Ethernet switch for SMB access networks, with 10/100/1000BASE-T ports, 1G/2.5G ports and optional PoE+ and PoE++ ports.
Overview. The H3C S5000NV6-EI is a managed Ethernet access switch from the S5000NV6-EI series, designed for the SMB market, government, schools and hotels. It offers high-performance access, enhanced security access policy control and improved network manageability and maintenance.
Main characteristics. Eight models are available, with 4, 12, 20 or 48 10/100/1000BASE-T copper ports, 1G/2.5G BASE-T ports and 2 or 4 1G/2.5G BASE-X SFP ports depending on the model. The CPU runs at 1.2 GHz, with 256 MB of flash, 1 GB of SDRAM and a VLAN table of 4K entries. System switching capacity reaches 232 Gbps, port switching capacity 38 Gbps and forwarding capacity 29 Mpps, with latency of 5 μs or less. The MAC address table holds 16K entries.
Interfaces and connectivity. PoE+ and PoE++ ports are available on the corresponding models: on the S5000NV6-12P4UN4NS-EI, ports 1 to 4 provide 35 W and ports 5 to 8 provide 100 W. Link aggregation is supported statically, dynamically and through LACP, as well as S-MLAG. Static routing and multicast functions (IGMP Snooping, MLD Snooping, PIM snooping, Multicast VLAN) are supported.
Security and quality of service. The switch provides ACL, advanced and user-defined access control lists applied on ingress and egress, together with CAR and Diff-Serv QoS. Eight queues per port are available with SP, WRR and SP+WRR scheduling, traffic classification by source and destination MAC, IP, port, protocol and VLAN, traffic shaping and time ranges. High-availability features include Ethernet OAM (IEEE 802.3ah), DLDP, ERPS (G.8032) and CPU protection.
Power and environment. The power input accepts a rated range of 100 to 240 VAC at 50 or 60 Hz. The operating temperature ranges from –5 °C to +45 °C, decreasing by 0.33 °C for every 100 m of altitude above 0 m. Storage is rated from –40 °C to +70 °C. Cooling is passive and fanless, and static power consumption with no load is 7 W. The weight is 1.1 kg or less and the dimensions are 43.6 × 266 × 160 mm.
Typical use. This switch suits the construction of access networks in government offices, SMBs, schools and hotels, connecting workstations, access points and PoE devices.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for S5000NV6-EI, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| ACL/QoS | ACL (Access Control List); Advanced ACL; User-defined ACL; Ingress and Egress ACL; CAR; Diff-Serv QoS; Eight queues on a port; Flexible queue scheduling algorithms including SP, WRR, SP+WRR; Traffic shaping; Traffic redirecting; Time ranges; Traffic classification based on source MAC, destination MAC, source IP, destination IP, port, protocol, and VLAN |
| Active VLAN | 4K |
| Buffer | 0.5MB |
| CPU | 1.2GHz |
| Dimensions (H x W x D) | 43.6 × 266 × 160 mm |
| EMC | ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; CISPR 35; AS/NZS CISPR 32; EN 55035; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386 |
| Ethernet link aggregation | Static aggregation; Dynamic aggregation; Port aggregation; LACP (Link Aggregation Control Protocol); S-MLAG |
| Fan NUM | Fanless, passive cooling |
| Flash | 256MB |
| Forwarding | Hardware-based (ASlC) Wire-speed/Line-rate architecture; Store-and-forward |
| Forwarding Capacity | 29Mpps |
| High availability | Ethernet OAM (IEEE 802.3ah); DLDP (Device Link Detection Protocol); ERPS (G.8032 Ethernet Ring Protection Switching); CPU protection; Hot patching; Link aggregation |
| Input Voltage | Rated voltage range: 100 VAC to 240 VAC @ 50 Hz or 60 Hz; Max voltage range: 90 VAC to 264 VAC @ 47 Hz to 63 Hz |
| IPv4 ARP entries | 64(Static), 512(Dynamic) |
| Latency (64byte LIFO) | ≤5μs |
| LS-5000NV6-12P4UN4NS-EI-GL | H3C S5000NV6-12P4UN4NS-EI Ethernet Switch with 12*10/100/1000BASE-T PoE+ Ports, 4*1G/2.5G BASE-T PoE++ Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-12T4N4NS-EI-GL | H3C S5000NV6-12T4N4NS-EI Ethernet Switch with 12*10/100/1000BASE-T Ports, 4*1G/2.5G BASE-T Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-20P4UN4NS-EI-GL | H3C S5000NV6-20P4UN4NS-EI Ethernet Switch with 20*10/100/1000BASE-T PoE+ Ports, 4*1G/2.5G BASE-T PoE++ Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-20T4N4NS-EI-GL | H3C S5000NV6-20T4N4NS-EI Ethernet Switch with 20*10/100/1000BASE-T Ports, 4*1G/2.5G BASE-T Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-48P4NS-EI-GL | H3C S5000NV6-48P4NS-EI Ethernet Switch with 48*10/100/1000BASE-T PoE+ Ports and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-48T4NS-EI-GL | H3C S5000NV6-48T4NS-EI Ethernet Switch with 48*10/100/1000BASE-T Ports and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-4P4UN2NS-EI-GL | H3C S5000NV6-4P4UN2NS-EI Ethernet Switch with 4*10/100/1000BASE-T PoE+ Ports, 4*1G/2.5G BASE-T PoE++ Ports, and 2*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-4T4N2NS-EI-GL | H3C S5000NV6-4T4N2NS-EI Ethernet Switch with 4*10/100/1000BASE-T Ports, 4*1G/2.5G BASE-T Ports, and 2*1G/2.5G BASE-X SFP Ports,(AC) |
| MAC address entries | 16K |
| Multicast | PIM snooping; IGMP Snooping; IPv6 PIM snooping; MLD Snooping; Multicast VLAN |
| Operating/Storage Humidity | 5% RH to 95% RH, non-condensing |
| Operating Temperature | –5°C to +45°C (23°F to 113°F); Note:; The maximum acceptable temperature decreases by 0.33°C (0.59°F) for every 100 m (328.08 ft) increase in altitude from 0 m (0 ft). |
| PoE | Ports 1 to 4: 35 W; Ports 5 to 8: 100 W |
| Port Switching Capacity | 38Gbps |
| Power consumption (static); Data collection standard: no load | 7 W |
| RoHS | EU RoHS2.0 Directive; China RoHS 2.0 |
| Routing | Static routing |
| S5000NV6-12P4UN4NS-EI | 12*10/100/1000BASE-T PoE+ Ports, 4*1G/2.5G BASE-T PoE++ Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-12T4N4NS-EI | 12*10/100/1000BASE-T Ports, 4*1G/2.5G BASE-T Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-20P4UN4NS-EI | 20*10/100/1000BASE-T PoE+ Ports, 4*1G/2.5G BASE-T PoE++ Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-20T4N4NS-EI | 20*10/100/1000BASE-T Ports, 4*1G/2.5G BASE-T Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-48P4NS-EI | 48*10/100/1000BASE-T PoE+ Ports and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-48T4NS-EI | 48*10/100/1000BASE-T Ports and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-4P4UN2NS-EI | 4*10/100/1000BASE-T PoE+ Ports, 4*1G/2.5G BASE-T PoE++ Ports, and 2*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-4T4N2NS-EI | 4*10/100/1000BASE-T Ports, 4*1G/2.5G BASE-T Ports, and 2*1G/2.5G BASE-X SFP Ports,(AC) |
| Safety | CSA C22.2 No. 62368-1-14; IEC 62368-1; EN 62368-1; EN 60825-1; AS/NZS 62368-1; GB 4943.1 |
| SDRAM | 1G |
| Storage Temperature | -40ºC ~ +70ºC |
| System switching capacity * | 232Gbps |
| VLAN Table | 4K |
| Weight | ≤ 1.1 kg |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for S5000NV6-EI. For a missing document or a specific revision, our experts send it to you.
The H3C S5000NV6-EI is a Gigabit managed Ethernet switch for SMB access networks, with 10/100/1000BASE-T ports, 1G/2.5G ports and optional PoE+ and PoE++ ports.
| Parameter | Value |
|---|---|
| ACL/QoS | ACL (Access Control List); Advanced ACL; User-defined ACL; Ingress and Egress ACL; CAR; Diff-Serv QoS; Eight queues on a port; Flexible queue scheduling algorithms including SP, WRR, SP+WRR; Traffic shaping; Traffic redirecting; Time ranges; Traffic classification based on source MAC, destination MAC, source IP, destination IP, port, protocol, and VLAN |
| Active VLAN | 4K |
| Buffer | 0.5MB |
| CPU | 1.2GHz |
| Dimensions (H x W x D) | 43.6 × 266 × 160 mm |
| EMC | ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; CISPR 35; AS/NZS CISPR 32; EN 55035; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386 |
| Ethernet link aggregation | Static aggregation; Dynamic aggregation; Port aggregation; LACP (Link Aggregation Control Protocol); S-MLAG |
| Fan NUM | Fanless, passive cooling |
| Flash | 256MB |
| Forwarding | Hardware-based (ASlC) Wire-speed/Line-rate architecture; Store-and-forward |
| Forwarding Capacity | 29Mpps |
| High availability | Ethernet OAM (IEEE 802.3ah); DLDP (Device Link Detection Protocol); ERPS (G.8032 Ethernet Ring Protection Switching); CPU protection; Hot patching; Link aggregation |
| Input Voltage | Rated voltage range: 100 VAC to 240 VAC @ 50 Hz or 60 Hz; Max voltage range: 90 VAC to 264 VAC @ 47 Hz to 63 Hz |
| IPv4 ARP entries | 64(Static), 512(Dynamic) |
| Latency (64byte LIFO) | ≤5μs |
| LS-5000NV6-12P4UN4NS-EI-GL | H3C S5000NV6-12P4UN4NS-EI Ethernet Switch with 12*10/100/1000BASE-T PoE+ Ports, 4*1G/2.5G BASE-T PoE++ Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-12T4N4NS-EI-GL | H3C S5000NV6-12T4N4NS-EI Ethernet Switch with 12*10/100/1000BASE-T Ports, 4*1G/2.5G BASE-T Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-20P4UN4NS-EI-GL | H3C S5000NV6-20P4UN4NS-EI Ethernet Switch with 20*10/100/1000BASE-T PoE+ Ports, 4*1G/2.5G BASE-T PoE++ Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-20T4N4NS-EI-GL | H3C S5000NV6-20T4N4NS-EI Ethernet Switch with 20*10/100/1000BASE-T Ports, 4*1G/2.5G BASE-T Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-48P4NS-EI-GL | H3C S5000NV6-48P4NS-EI Ethernet Switch with 48*10/100/1000BASE-T PoE+ Ports and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-48T4NS-EI-GL | H3C S5000NV6-48T4NS-EI Ethernet Switch with 48*10/100/1000BASE-T Ports and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-4P4UN2NS-EI-GL | H3C S5000NV6-4P4UN2NS-EI Ethernet Switch with 4*10/100/1000BASE-T PoE+ Ports, 4*1G/2.5G BASE-T PoE++ Ports, and 2*1G/2.5G BASE-X SFP Ports,(AC) |
| LS-5000NV6-4T4N2NS-EI-GL | H3C S5000NV6-4T4N2NS-EI Ethernet Switch with 4*10/100/1000BASE-T Ports, 4*1G/2.5G BASE-T Ports, and 2*1G/2.5G BASE-X SFP Ports,(AC) |
| MAC address entries | 16K |
| Multicast | PIM snooping; IGMP Snooping; IPv6 PIM snooping; MLD Snooping; Multicast VLAN |
| Operating/Storage Humidity | 5% RH to 95% RH, non-condensing |
| Operating Temperature | –5°C to +45°C (23°F to 113°F); Note:; The maximum acceptable temperature decreases by 0.33°C (0.59°F) for every 100 m (328.08 ft) increase in altitude from 0 m (0 ft). |
| PoE | Ports 1 to 4: 35 W; Ports 5 to 8: 100 W |
| Port Switching Capacity | 38Gbps |
| Power consumption (static); Data collection standard: no load | 7 W |
| RoHS | EU RoHS2.0 Directive; China RoHS 2.0 |
| Routing | Static routing |
| S5000NV6-12P4UN4NS-EI | 12*10/100/1000BASE-T PoE+ Ports, 4*1G/2.5G BASE-T PoE++ Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-12T4N4NS-EI | 12*10/100/1000BASE-T Ports, 4*1G/2.5G BASE-T Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-20P4UN4NS-EI | 20*10/100/1000BASE-T PoE+ Ports, 4*1G/2.5G BASE-T PoE++ Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-20T4N4NS-EI | 20*10/100/1000BASE-T Ports, 4*1G/2.5G BASE-T Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-48P4NS-EI | 48*10/100/1000BASE-T PoE+ Ports and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-48T4NS-EI | 48*10/100/1000BASE-T Ports and 4*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-4P4UN2NS-EI | 4*10/100/1000BASE-T PoE+ Ports, 4*1G/2.5G BASE-T PoE++ Ports, and 2*1G/2.5G BASE-X SFP Ports,(AC) |
| S5000NV6-4T4N2NS-EI | 4*10/100/1000BASE-T Ports, 4*1G/2.5G BASE-T Ports, and 2*1G/2.5G BASE-X SFP Ports,(AC) |
| Safety | CSA C22.2 No. 62368-1-14; IEC 62368-1; EN 62368-1; EN 60825-1; AS/NZS 62368-1; GB 4943.1 |
| SDRAM | 1G |
| Storage Temperature | -40ºC ~ +70ºC |
| System switching capacity * | 232Gbps |
| VLAN Table | 4K |
| Weight | ≤ 1.1 kg |
Answers to the questions that the recorded characteristics of S5000NV6-EI can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Ethernet link aggregation": Static aggregation; Dynamic aggregation; Port aggregation; LACP (Link Aggregation Control Protocol); S-MLAG.
Yes — recorded under "LS-5000NV6-12P4UN4NS-EI-GL": H3C S5000NV6-12P4UN4NS-EI Ethernet Switch with 12*10/100/1000BASE-T PoE+ Ports, 4*1G/2.5G BASE-T PoE++ Ports, and 4*1G/2.5G BASE-X SFP Ports,(AC).
–5°C to +45°C (23°F to 113°F); Note:; The maximum acceptable temperature decreases by 0.33°C (0.59°F) for every 100 m (328.08 ft) increase in altitude from 0 m (0 ft). (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Gigabit managed PoE+ access switch for campus networks

H3C Series Enhanced Gigabit Access Switches

H3C Series Enhanced Gigabit Access Switches

GbE L2+ Managed Switch

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | S5000NV6-EI |
| Manufacturer | H3C |
Campus Access Switches
Fully managed 48-port 1G PoE+ switch with 2 10G and 2 SFP+ ports · Ref. : GSM4352PB
Price on request
Campus Access Switches
Industrial Gigabit managed PoE switch with SFP ports · Ref. : DIS-300G-8PSW
Price on request
Campus Access Switches
Layer 2 PoE campus access switch, 5 ports
Price on request
Campus Access Switches
Multi-gigabit managed switch with 8x 2.5G ports and 10G SFP+ ports · Ref. : GWN7721
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details