| Automatic Configuration | Server-based automatic configuration; USB-based automatic configuration |
| Box Switching capacity | 2.56Tbps |
| CAB-CON-1.8m | Single Cable, Console Serial Port Cable,1.8m,D9F,28UL20276(4P)(P296U),MPH-8P8C |
| CPU | Dual Core, 1.6GHz |
| Dimensions H*W*D | 43.6 × 440 × 360 mm |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; CISPR 35; AS/NZS CISPR 32; EN 55035; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386 |
| Energy saving | Port automatic power down function; Port timing down function (Schedule job); EEE(802.3az Energy Efficient Ethernet) |
| Entries | S6520X-EI Series Switches |
| Ethernet configuration | Static aggregation; Dynamic aggregation; S-MLAG(Simple multichassis link aggregation); 10GE/25G/40GE/100GE port aggregation; LACP(Link Aggregation Control Protocol); M-LAG(Multichassis Link Aggregation); AutoMDIX; Speed Auto/Manual; Duplex Auto/Full/Half |
| Expansion cards | Expansion cards |
| Expansion Modules | 2-Port 10G SFP+ Ethernet Optical Interface Module; 4-Port 10G SFP+ Ethernet Optical Interface Module; 8-Port 10G SFP Plus Interface Card; 8-Port 10G SFP+ with MACSec Interface Module; 8-Port 1/2.5/5G BASE-T Ethernet Copper Interface Module; 8-Port 1/2.5/5/10G BASE-T Ethernet Copper Interface Module; 2-port 25GE SFP28 interface module; 2-port 40GE QSFP+ interface module; 8-port 25GE SFP28 interface module (for S6520X-54HC-EI); 2-port 100GE QSFP28 interface module (for S6520X-54HC-EI) |
| FAN-40B-1-A | Not supported |
| Fan trays | 2 hot swappable fan trays, automatic multi-level adjustable speed, and invertible airflow |
| Flash | 1GB |
| Forwarding | Hardware-based(ASlC)Wire-speed/Line-rate architecture |
| Idle power consumption (30% of traffic load, tested according to ATIS standard) | Single AC: 38W; Dual AC: 43W |
| IEEE | 802.1x Port based network access control protocol |
| IETF | RFC 1213 Management Information Base (MIB-II) |
| Input voltage range | AC power supply:; Rated voltage range: 100 to 240 VAC @ 50/60 Hz; Max voltage range: 90 to 290 VAC @ 47to 63 Hz; High voltage input: 240V DC; DC power supply:; Rated voltage range: –48 to–60VDC; Max voltage range: –36 to–72VDC |
| Intelligent Lossless Network | PFC(Priority-based Flow Control); ECN(Explicit Congestion Notification ) |
| IPv4 ACL entries | Ingress:2048; Egress:256 |
| IPv4 ARP entries(max) | 65,536 |
| IPv4 routing entries(max) | 65,536 |
| IPv6 ACL entries | Ingress:2048; Egress:256 |
| IPv6 ND entries | 32,768 |
| IPv6 unicast routing entries | 32,768 |
| ITU | ITU-T Y.1731 |
| LIS-WX-128-BE | Enhanced Access Controller License,128 APs |
| LIS-WX-16-BE | Enhanced Access Controller License,16 APs |
| LIS-WX-1-BE | Enhanced Access Controller License,1 AP |
| LIS-WX-32-BE | Enhanced Access Controller License,32 APs |
| LIS-WX-8-BE | Enhanced Access Controller License,8 APs |
| LS-6520X-30HC-EI-GL | H3C S6520X-30HC-EI L3 Ethernet Switch (24SFP Plus+2QSFP28+2Slot), No Power |
| LS-6520X-30HF-EI | H3C S6520X-30HF-EI L3 Ethernet Switch (24SFP Plus+6QSFP28), No Power |
| LS-6520X-30QC-EI-GL | H3C S6520X-30QC-EI L3 Ethernet Switch (24SFP Plus+2QSFP Plus+2Slot), No Power |
| LS-6520X-54HC-EI-GL | H3C S6520X-54HC-EI L3 Ethernet Switch (48SFP Plus+2QSFP28+2Slot), No Power |
| LS-6520X-54HC-UPWR-EI | H3C S6520X-54HC-UPWR-EI, L3 Ethernet Switch(24*10GBase-T(PoE++) +4*QSFP28+1E-Slot+1Slot), (Without Power Supplies) |
| LS-6520X-54HF-EI | H3C S6520X-54HF-EI L3 Ethernet Switch (48SFP Plus+6QSFP28), No Power |
| LS-6520X-54QC-EI-GL | H3C S6520X-54QC-EI L3 Ethernet Switch (48SFP Plus+2QSFP Plus+2Slot), No Power |
| LSPM1FANSA-SN | Not supported |
| LSPM1FANSB-SN | Not supported |
| LSWM124MUPWR | Not supported |
| LSWM124SFPP | Not supported |
| LSWM1FANSCBE | Supported |
| LSWM1FANSCE | Supported |
| LSWM1QSTK0 | 40G QSFP+ Cable 1m |
| LSWM1QSTK1 | 40G QSFP+ Cable 3m |
| LSWM1QSTK2 | 40G QSFP+ Cable 5m |
| LSWM1QSTK3 | 40G QSFP+ to 4x10G SFP+ Cable 1m |
| LSWM1QSTK4 | 40G QSFP+ to 4x10G SFP+ Cable 3m |
| LSWM1QSTK5 | 40G QSFP+ to 4x10G SFP+ Cable 5m |
| LSWM1STK | SFP+ Cable 0.65m |
| LSWM2MGT8P | Supported |
| LSWM2QP2P | Supported |
| LSWM2SP2PB | Supported |
| LSWM2SP4PB | Supported |
| LSWM2SP8P | Supported |
| LSWM2STK | SFP+ Cable 1.2m |
| LSWM2XMGT8P | Supported |
| LSWM2ZQP2P | Not supported |
| LSWM2ZSP2P | Supported |
| LSWM2ZSP8P | Not supported |
| LSWM3STK | SFP+ Cable 3m |
| LSWM4SP8PM | Supported |
| MAC address entries(max) | 131,072 |
| Max. power Consumption (100% throughput, full speed of fans) | Single AC: 197W; Dual AC: 200W |
| Max Stacking Bandwidth | 480Gbps |
| MPLS | Static LSP(label switched path); LDP(Label Distribution Protocol); IPv6 LDP; Tunnel policies; VRF(Virtual Routing and Forwarding); MPLS L2VPN; MPLS L3VPN; MPLS Ping/Tracert; MCE(Multi-VPN Instance Customer Edge); IPv6 MCE; MPLS OAM |
| MTBF(year) | 63.4 |
| Multicast | PIM-DM, PIM-SM, PIM-SSM, and Any-RP; PIM snooping; MSDP(Multicast Source Discovery Protocol); IGMPv1/IGMPv2/IGMPv3; IGMP proxying; IGMP Snooping; IGMP snooping proxying; IGMP Filter and IGMP Fast leave; IPv6 PIM-DM, PIM-SM, PIM-SSM, and Any-RP; IPv6 PIM snooping; MLDv1/MLDV2; MLD proxying; MLD Snooping; MLD snooping proxying; Multicast routing and forwarding; Multicast VLAN; MVPN(Multicast VPN); Multicast policy and Multicast QoS |
| OP-MPO8-8LC-10-M | Fiber Connector,MPO(8 core)/PC,8LC/PC(0.5m),Multimode(OM3),3.0mm,10.0m |
| OP-MPO8-MPO8-100-M | Fiber connector,MPO(8 core)/PC,MPO(8 core)/PC,Multimode(OM3),3.0mm,100.0m |
| OP-MPO8-MPO8-10-M | Fiber connector,MPO(8 core)/PC,MPO(8 core)/PC,Multimode(OM3),3.0mm,10.0m |
| OP-MPO8-MPO8-200-M | Fiber connector,MPO(8 core)/PC,MPO(8 core)/PC,Multimode(OM3),3.0mm,200.0m |
| OP-MPO8-MPO8-50-M | Fiber connector,MPO(8 core)/PC,MPO(8 core)/PC,Multimode(OM3),3.0mm,50.0m |
| OpenFlow | OpenFlow 1.3; Multiple controllers (EQUAL, master/slave); Multiple tables flow; Group table |
| Operating/Storage Humidity | 5% RH to 95% RH, non-condensing |
| Operating Temperature | 0℃ to 45℃ (32℉to 113℉); -60m-5000m altitude: From 0m, the maximum operating temperature reduce by 0.33℃ for every time 100 the altitude increases by 100m. |
| Organization | Standards and Protocols |
| Packet Buffer | 10M |
| Packet Forwarding Rate | 705Mpps |
| Port Switching Capacity | 1200Gbps |
| Power supply — 1 | Total PoE power capacity |
| Power supply slots | 2(Hot swappable) |
| Product ID | Product Description |
| Programmability and Automation | Ansible; Auto DevOps by using Python, NETCONF, TCL, and RESTful/RESTCONF API for automated network programming |
| PSR1600-54A-B | 1600W AC Power Supply module (only for S6520X-54HC-UPWR-EI) |
| PSR1600-54A-B (Input Voltage:176V AC~290V AC or 180V DC~320V DC) | 1290W |
| PSR1600-54A-B (Input Voltage: 90V AC~176V AC) | 630W |
| PSR1600-54AB | Not supported |
| PSR180-12A-B | Not supported |
| PSR180-12A-F | Not supported |
| PSR180-12D-B | Not supported |
| PSR250-12A | Supported |
| PSR250-12A1 | Supported |
| PSR250-12A1-GL | 250W AC Power Supply Module |
| PSR250-12A-GL | 250W AC Power Supply Module |
| PSR450-12D | Supported |
| PSR600-54A-B | 300W |
| PSR600-54AB | Not supported |
| PSR920-54A-B | 630W |
| PSR920-54A-B (Input Voltage: 176V AC~290V AC or 180V DC~320V DC) | 1440W |
| PSR920-54A-B (Input Voltage: 90V AC~176V AC) | 1100W |
| PSR920-54AB | Not supported |
| QSFP-100G-4SFP-25G-CAB-1M | 100G QSFP28 to 4x25G SFP28 1m Passive Cable |
| QSFP-100G-4SFP-25G-CAB-3M | 100G QSFP28 to 4x25G SFP28 3m Passive Cable |
| QSFP-100G-4SFP-25G-CAB-5M | 100G QSFP28 to 4x25G SFP28 5m Passive Cable |
| QSFP-100G-D-AOC-10M | 100G QSFP28 to 100G QSFP28 10m Active Optical Cable |
| QSFP-100G-D-AOC-20M | 100G QSFP28 to 100G QSFP28 20m Active Optical Cable |
| QSFP-100G-D-AOC-7M | 100G QSFP28 to 100G QSFP28 7m Active Optical Cable |
| QSFP-100G-D-CAB-1M | 100G QSFP28 to 100G QSFP28 1m Passive Cable |
| QSFP-100G-D-CAB-3M | 100G QSFP28 to 100G QSFP28 3m Passive Cable |
| QSFP-100G-D-CAB-5M | 100G QSFP28 to 100G QSFP28 5m Passive Cable |
| QSFP-100G-LR4-WDM1300 | 100G QSFP28 Optical Transceiver Module(1310nm,10km,LR4,WDM,LC) |
| QSFP-100G-LR4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,2km,LR4L,CWDM4,LC) |
| QSFP-100G-SR4-MM850 | 100G QSFP28 Optical Transceiver Module (850nm,100m OM4,SR4,MPO) |
| QSFP-40G-CSR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,300m,CSR4,Support 40G to 4*10G) |
| QSFP-40G-LR4-WDM1300 | 40GBASE-LR4 QSFP+ Optical Transceiver Module |
| QSFP-40G-SR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,100m, SR4,Support 40G to 4*10G) |
| Removable fan trays | Removable fan trays |
| Removable power supplies | Removable power supplies |
| RoHS | EU RoHS2.0 Directive; China RoHS 2.0 |
| Routing | Static routing, RIP, OSPF, IS-IS, and BGP; IPv6 static routing, RIPng, OSPFv3, IS-ISv6, and BGP4+; IPv4/IPv6 dual stack; IPv4/IPv6 ECMP(Equal-cost multi-path routing); IPv4/IPv6 PBR(Policy-based routing); IPv4/IPv6 Routing policy; Pingv6, Telnetv6, FTPv6, TFTPv6, DNSv6, ICMPv6; Dual-stack PBR(policy-based routing) |
| Safety | UL 62368-1; CSA C22.2 No. 62368-1-14; IEC 62368-1; EN 62368-1; EN 60825-1; AS/NZS 62368-1; GB 4943.1 |
| SDRAM | 2GB |
| SFP-10GE-T | SFP+ 10GE Copper Interface Transceiver Module (Cat6a/Cat7,30m, RJ45) |
| SFP-25G-D-CAB-1M | 25G SFP28 to 25G SFP28 1m Passive Cable |
| SFP-25G-D-CAB-3M | 25G SFP28 to 25G SFP28 3m Passive Cable |
| SFP-25G-D-CAB-5M | 25G SFP28 to 25G SFP28 5m Passive Cable |
| SFP-25G-SR-MM850 | 25G SFP28 Optical Transceiver Module (850nm,100m,SR,MM,LC) |
| SFP-GE-LH100-SM1550 | 1000BASE-LH100 SFP Transceiver, Single Mode (1550nm, 100km, LC) |
| SFP-GE-LH40-SM1310 | 1000BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| SFP-GE-LH40-SM1550 | 1000BASE-LH40 SFP Transceiver, Single Mode (1550nm, 40km, LC) |
| SFP-GE-LH80-SM1550 | 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC) |
| SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| SFP-GE-LX-SM1310-BIDI | 1000BASE-LX BIDI SFP Transceiver, Single Mode (TX1310/RX1490, 10km, LC) |
| SFP-GE-LX-SM1490-BIDI | 1000BASE-LX BIDI SFP Transceiver, Single Mode (TX1490/RX1310, 10km, LC) |
| SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| SFP-GE-T | 1000BASE-T SFP |
| SFP-XG-LH40-SM1550 | SFP+ Module (1550nm,40km, LC) |
| SFP-XG-LX-SM1310-E | SFP+ Module (1310nm,10km, LC) |
| SFP-XG-SX-MM850-E | SFP+ Module (850nm,300m, LC) |
| Stacking | IRF2(Intelligent Resilient Framework 2); Distributed device management; Distributed link aggregation; Distributed resilient routing; Stacking through standard Ethernet ports; Local device stacking and remote device stacking; LACP-, BFD-, and ARP-based multi-active detection (MAD) |
| Storage Temperature | -40℃ to 70℃(-40℉ to 158℉) |
| Visualization | gRPC(Google remote procedure call); INT(Inband Telemetry); Flow group; MOD(Mirror On Drop) |
| VXLAN | VXLAN L2 switching; VXLAN L3 routing; Centralized VXLAN gateway; Distributed VXLAN gateway; VXLAN M-LAG; VXLAN-DCI; OVSDB(Open vSwitch Database); VXLAN VTEP; MP-BGP EVPN control plane; EVPN VXLAN; EVPN M-LAG |
| Weight | ≤7.4KG |