S6550X-HI
High-Density 40G/100G Layer 3 Switch for Data Centers

- Operating Temperature
- -5~45°C
- VLAN interface
- 1K
- AC input voltage
- 100V to 240V
- DC Input Voltage
- 48V to 64V
High-Density 40G/100G Layer 3 Switch for Data Centers
The H3C S6550X-HI is a high-density Layer 3 switch for data center and cloud networks, for 25GE, 40GE and 100GE server access and aggregation.
Overview. The H3C S6550X-HI is a Layer 3 switch from the S6550X-HI series, designed for data center and cloud computing networks. It provides high-density 40G/100G ports and can also operate as a TOR access switch on an overlay or integrated network.
Main characteristics. Switching capacity of 6.4 Tbps, packet forwarding rate of 2800 Mpps, packet buffer of 24M, up to 256K MAC address entries and up to 504K IPv4 routing entries. The 100G ports are 100G/40G autosensing and each can be split into four interfaces. The CPU runs at 2.0 GHz.
Interfaces and connectivity. 40GE/100GE port aggregation, LACP, IRF2 with stacking fast convergence within 50 ms, and one out-of-band management port 10/100/1000Base-T. VXLAN, EVPN distributed gateway, OpenFlow 1.3.1, RDMA and RoCE, and 802.1Qbb PFC are supported for data center environments.
Routing and protocols. Static routing, RIPv1/v2, OSPFv1/v2/v3, BGP, IS-IS, ECMP and VRRP for IPv4 and IPv6, plus MPLS L3VPN and VPLS. Multicast with IGMP snooping, PIM-DM/SM and MSDP.
Power and environment. AC input voltage 100V to 240V or DC input voltage 48V to 64V depending on the power module. Power consumption at full load of 390.5 W with a single AC supply. Operating temperature -5 to 45 °C, operating humidity 5% to 95%. Dimensions 43.6 × 440 × 400 mm, airflow from front to back depending on the fan module.
Management and security. Configuration via CLI, Telnet and console port, SNMPv1/v2c/v3, telemetry, gRPC, PTP, NTP and sFlow. AAA/RADIUS/HWTACACS authentication, SSH 2.0, 802.1X, IP address, MAC address and port binding, IP Source Guard.
Typical uses. High-density 25GE, 40GE or 100GE server access and aggregation in data centers and cloud networks.
Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for S6550X-HI, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| AC input voltage | 100V to 240V |
| Air flow direction | From front to back |
| ARP | Gratuitous ARP; Dynamic ARP inspection; ARP source-suppression; ARP black hole; Multicast ARP; ARP detection |
| ARP entries | 96K max |
| Cables — LSWM1QSTK0 | 40G QSFP+ Cable 1m |
| Cables — LSWM1QSTK1 | 40G QSFP+ Cable 3m |
| Cables — LSWM1QSTK2 | 40G QSFP+ Cable 5m |
| Cables — LSWM1QSTK3 | 40G QSFP+ to 4x10G SFP+ Cable 1m |
| Cables — LSWM1QSTK4 | 40G QSFP+ to 4x10G SFP+ Cable 3m |
| Cables — LSWM1QSTK5 | 40G QSFP+ to 4x10G SFP+ Cable 5m |
| CPU Frequency | 2.0GHz |
| Data Center | VXLAN; 802.1Qbb PFC, 802.1Qaz; OpenFlow 1.3.1; Multiple types of OpenFlow controllers; EVPN distributed gateway; NETCONF, Python; Service chain; RDMA, RoCE |
| DC Input Voltage | 48V to 64V |
| DHCP | DHCP server/client; DHCP snooping/DHCP relay; DHCP snooping support for Option 82/DHCP relay agent support for Option 82; IPv6 DHCP server/client; IPv6 DHCP snooping/DHCP relay |
| Dimensions H*W*D | 43.6 × 440 × 400 mm (1.72 × 17.32 × 15.75 in) |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 24; EN 55024; EN 61000-3-2; EN 61000-3-3; GB/T 9254; YD/T 993 |
| Fan — FAN-40B-1-A | H3C Asset-Manageable Fan Module (Fan Panel Side Exhaust Airflow) |
| Fan — FAN-40F-1-A | H3C Asset-Manageable Fan Module (Fan Panel Side Intake Airflow) |
| Flash/SDRAM | 4GB/8GB |
| Forwarding Mode | Store-forward modes |
| IEEE Standard | 802.3x; 802.3ad; 802.3AH; 802.1P; 802.1Q; 802.1X; 802.1D; 802.1w; 802.1s; 802.1AG; 802.1x; 802.1Qbb; 802.1az; 802.1Qaz |
| IP Routing | Stating routing, RIPv1/v2, OSPFv1/v2/v3, BGP, IS-IS; ECMP, VRRP, policy-based routing; BGP4+ for IPv6, VRRP, IPv6 policy-based routing; RIPng, OSPFv3, ISISv6; GenericRoutingEncapsulation(GRE) |
| IPv4 routing entries | 504K max |
| IPV6 | IPv6 ND; IPv6 PMTU; ICMPv6, Telnetv6, SFTPv6, SNMP over IPv6, BFDv6, VRRPv3; IPv6 portal; IPv6 tunnel |
| IPv6 unicast routing entries | 252K max |
| Jumbo frame length | 10000 Bytes |
| LACP | LACP; LACP local forwarding first; LACP short-time; LACP Stack split detection |
| Link aggregation | 40GE/100GE port aggregation; Static aggregation, dynamic aggregation |
| Link layer | LLDP; LLDP-MED; DLDP |
| Loading and upgrading | Loading/upgrading through the XMODEM protocol; Loading/upgrading through FTP and TFTP |
| MAC address entries | 256K max |
| MAC Address Table | Static MAC address; Black hole MAC address |
| Management and maintenance | Configuration via CLI, Telnet, and Console port; SNMPv1/v2c/v3; Telemetry; gRPC; PTP; IMC; System logs; Hierarchical alarms; NTP, SNTP; Power, fan and temperature alarms; Debugging information output; Ping and Tracert; File uploading and downloading through the USB port |
| Max stacking member | 4(S6550X-54H-HI Max stacking member 2) |
| Mirroring | Traffic mirroring; N:4 port mirroring; Local port mirroring, remote port mirroring; Multiple remote mirroring ports (reflector-port) |
| MPLS | MPLS L3VPN; VPLS; VRF(Virtual Routing Forwarding) |
| MSTP | STP/RSTP/MSTP; PVST+/RPVST+; STP root guard; BPDU guard |
| Multicast | IGMP snooping v2/v3; IGMPv1/v2/v3; PIM-DM/SM; IPv6 PIM-DM/SM/SSM; Bi-directional-PIM; MSDP; MLD snooping; MBGP; Multicast policy |
| ND entries | 96K max |
| Operating Humidity | 5%~95% |
| Operating Temperature | -5~45°C |
| Out-of-band management port | 1 × 10/100/1000Base-T |
| Packet Buffer | 24M |
| Packet Forwarding Rate | 2800Mpps |
| Port Switching Capacity | 6.4T |
| Power consumption (at full load) | Single AC: 390.5W; Single DC: 410.1W; Dual AC: 386.3W; Dual DC: 404.2W |
| Power consumption (static) | Single AC: 81.54W; Single DC: 82.56W; Dual AC: 92.53W; Dual DC: 90.28W |
| Power supply — PSR450-12A | 450W AC Power Supply Module (Power Panel Side Intake Airflow) |
| Power supply — PSR450-12A1 | 450W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — PSR450-12AHD | 450W HVDC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — PSR450-12D | 450W DC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — UN-GW-CRPS800N2 | 800W AC & 240V HVDC Power Supply(GW-R2-Platinum-Light Load and High Efficiency)(CTO&BTO) |
| Power supply — UN-GW-CRPS800N2-1 | 800W AC &240V HVDC Power Supply (GW-R2-Platinum-Light Load and High Efficiency)(Excluding Cables)(CTO&BTO) |
| Product code — LS-6550X-32H-HI | H3C S6550X-32H-HI L3 Ethernet Switch with 32*QSFP28 Ports and 1*Slot. Without Power Supplies |
| Product code — LS-6550X-32Q-HI | H3C S6550X-32Q-HI L3 Ethernet Switch with 28*QSFP Plus Ports,4*QSFP28 Ports and 1*Slot. Without Power Supplies |
| Product code — LS-6550X-54H-HI | H3C S6550X-54H-HI L3 Ethernet Switch with 54*40G/100G QSFP28 Ports,Without Power Supplies |
| Product code — LS-6550X-56HF-HI | H3C S6550X-56HF-HI L3 Ethernet Switch with 48*SFP28 Ports,8*QSFP28 Ports and 1*Slot. Without Power Supplies |
| QoS/ACL | Inbound and outbound traffic rate limit; CAR; Eight output queues on each port; Flexible port-and queue-based queuing and scheduling algorithms; SP, WRR, and SP+WRR queuing; 802.1p and DSCP priority re-marking; Packet filtering at Layer 2 to Layer 4; Traffic classification based on source MAC address, destination MAC address, source IPv4/IPv6 address, destination IPv4/IPv6 address, port number, protocol type, and VLAN; Time range; Inbound and outbound ACLs; VLAN-based ACL assignment |
| Safety | UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1, EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter JGB4943.1 |
| Security | Hierarchical user management and password protection; AAA/RADIUS/HWTACACS; SSH 2.0; IP address + MAC address + port number binding; IP Source Guard; HTTPs/SSL; PKI; 802.1X; MAC authentication; EAD; IPv6 RADIUS Sever; IPv6 port binding |
| Traffic monitoring | sFlow |
| Transceivers — QSFP-100G-4SFP-25G-CAB-1M | 100G QSFP28 to 4x25G SFP28 1m Passive Cable |
| Transceivers — QSFP-100G-4SFP-25G-CAB-3M | 100G QSFP28 to 4x25G SFP28 3m Passive Cable |
| Transceivers — QSFP-100G-4SFP-25G-CAB-5M | 100G QSFP28 to 4x25G SFP28 5m Passive Cable |
| Transceivers — QSFP-100G-D-AOC-10M | 100G QSFP28 to 100G QSFP28 10m Active Optical Cable |
| Transceivers — QSFP-100G-D-AOC-20M | 100G QSFP28 to 100G QSFP28 20m Active Optical Cable |
| Transceivers — QSFP-100G-D-AOC-7M | 100G QSFP28 to 100G QSFP28 7m Active Optical Cable |
| Transceivers — QSFP-100G-D-CAB-1M | 100G QSFP28 to 100G QSFP28 1m Passive Cable |
| Transceivers — QSFP-100G-D-CAB-3M | 100G QSFP28 to 100G QSFP28 3m Passive Cable |
| Transceivers — QSFP-100G-D-CAB-5M | 100G QSFP28 to 100G QSFP28 5m Passive Cable |
| Transceivers — QSFP-100G-LR4-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,10km, LR4, WDM, LC) |
| Transceivers — QSFP-100G-LR4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,2km, LR4L, CWDM4, LC) |
| Transceivers — QSFP-100G-SR4-MM850 | 100G QSFP28 Optical Transceiver Module (850nm,100m OM4, SR4, MPO) |
| Transceivers — QSFP-40G-BIDI-SR-MM850 | QSFP+ 40GBASE BIDI Optical Transceiver Module (850nm,100m, SR) |
| Transceivers — QSFP-40G-BIDI-WDM850 | QSFP+ 40GBASE BIDI Optical Transceiver Module (850nm,300m) |
| Transceivers — QSFP-40G-D-AOC-10M | 40G QSFP+ to 40G QSFP+ 10m Active Optical Cable |
| Transceivers — QSFP-40G-D-AOC-20M | 40G QSFP+ to 40G QSFP+ 20m Active Optical Cable |
| Transceivers — QSFP-40G-D-AOC-7M | 40G QSFP+ to 40G QSFP+ 7m Active Optical Cable |
| Transceivers — QSFP-40G-LR4-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,10km, LR4, LC) |
| Transceivers — QSFP-40G-LR4L-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,2km, LR4L, LC) |
| Transceivers — QSFP-40G-SR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,100m, SR4, Support 40G to 4*10G) |
| Virtualization | Intelligent Resilient Framework 2 (IRF2) (fast convergence within 50ms); Distributed device management; Distributed link aggregation; Distributed resilient routing; Stacking through standard Ethernet ports; Local device stacking and remote device stacking |
| VLAN | Port-based VLAN; Default VLAN |
| VLAN interface | 1K |
| Weight(Full loaded) | ≤ 9kg |
| Zero-configuration | Auto-config |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for S6550X-HI. For a missing document or a specific revision, our experts send it to you.
The H3C S6550X-HI is a high-density Layer 3 switch for data center and cloud networks, for 25GE, 40GE and 100GE server access and aggregation.
| Parameter | Value |
|---|---|
| AC input voltage | 100V to 240V |
| Air flow direction | From front to back |
| ARP | Gratuitous ARP; Dynamic ARP inspection; ARP source-suppression; ARP black hole; Multicast ARP; ARP detection |
| ARP entries | 96K max |
| Cables — LSWM1QSTK0 | 40G QSFP+ Cable 1m |
| Cables — LSWM1QSTK1 | 40G QSFP+ Cable 3m |
| Cables — LSWM1QSTK2 | 40G QSFP+ Cable 5m |
| Cables — LSWM1QSTK3 | 40G QSFP+ to 4x10G SFP+ Cable 1m |
| Cables — LSWM1QSTK4 | 40G QSFP+ to 4x10G SFP+ Cable 3m |
| Cables — LSWM1QSTK5 | 40G QSFP+ to 4x10G SFP+ Cable 5m |
| CPU Frequency | 2.0GHz |
| Data Center | VXLAN; 802.1Qbb PFC, 802.1Qaz; OpenFlow 1.3.1; Multiple types of OpenFlow controllers; EVPN distributed gateway; NETCONF, Python; Service chain; RDMA, RoCE |
| DC Input Voltage | 48V to 64V |
| DHCP | DHCP server/client; DHCP snooping/DHCP relay; DHCP snooping support for Option 82/DHCP relay agent support for Option 82; IPv6 DHCP server/client; IPv6 DHCP snooping/DHCP relay |
| Dimensions H*W*D | 43.6 × 440 × 400 mm (1.72 × 17.32 × 15.75 in) |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 24; EN 55024; EN 61000-3-2; EN 61000-3-3; GB/T 9254; YD/T 993 |
| Fan — FAN-40B-1-A | H3C Asset-Manageable Fan Module (Fan Panel Side Exhaust Airflow) |
| Fan — FAN-40F-1-A | H3C Asset-Manageable Fan Module (Fan Panel Side Intake Airflow) |
| Flash/SDRAM | 4GB/8GB |
| Forwarding Mode | Store-forward modes |
| IEEE Standard | 802.3x; 802.3ad; 802.3AH; 802.1P; 802.1Q; 802.1X; 802.1D; 802.1w; 802.1s; 802.1AG; 802.1x; 802.1Qbb; 802.1az; 802.1Qaz |
| IP Routing | Stating routing, RIPv1/v2, OSPFv1/v2/v3, BGP, IS-IS; ECMP, VRRP, policy-based routing; BGP4+ for IPv6, VRRP, IPv6 policy-based routing; RIPng, OSPFv3, ISISv6; GenericRoutingEncapsulation(GRE) |
| IPv4 routing entries | 504K max |
| IPV6 | IPv6 ND; IPv6 PMTU; ICMPv6, Telnetv6, SFTPv6, SNMP over IPv6, BFDv6, VRRPv3; IPv6 portal; IPv6 tunnel |
| IPv6 unicast routing entries | 252K max |
| Jumbo frame length | 10000 Bytes |
| LACP | LACP; LACP local forwarding first; LACP short-time; LACP Stack split detection |
| Link aggregation | 40GE/100GE port aggregation; Static aggregation, dynamic aggregation |
| Link layer | LLDP; LLDP-MED; DLDP |
| Loading and upgrading | Loading/upgrading through the XMODEM protocol; Loading/upgrading through FTP and TFTP |
| MAC address entries | 256K max |
| MAC Address Table | Static MAC address; Black hole MAC address |
| Management and maintenance | Configuration via CLI, Telnet, and Console port; SNMPv1/v2c/v3; Telemetry; gRPC; PTP; IMC; System logs; Hierarchical alarms; NTP, SNTP; Power, fan and temperature alarms; Debugging information output; Ping and Tracert; File uploading and downloading through the USB port |
| Max stacking member | 4(S6550X-54H-HI Max stacking member 2) |
| Mirroring | Traffic mirroring; N:4 port mirroring; Local port mirroring, remote port mirroring; Multiple remote mirroring ports (reflector-port) |
| MPLS | MPLS L3VPN; VPLS; VRF(Virtual Routing Forwarding) |
| MSTP | STP/RSTP/MSTP; PVST+/RPVST+; STP root guard; BPDU guard |
| Multicast | IGMP snooping v2/v3; IGMPv1/v2/v3; PIM-DM/SM; IPv6 PIM-DM/SM/SSM; Bi-directional-PIM; MSDP; MLD snooping; MBGP; Multicast policy |
| ND entries | 96K max |
| Operating Humidity | 5%~95% |
| Operating Temperature | -5~45°C |
| Out-of-band management port | 1 × 10/100/1000Base-T |
| Packet Buffer | 24M |
| Packet Forwarding Rate | 2800Mpps |
| Port Switching Capacity | 6.4T |
| Power consumption (at full load) | Single AC: 390.5W; Single DC: 410.1W; Dual AC: 386.3W; Dual DC: 404.2W |
| Power consumption (static) | Single AC: 81.54W; Single DC: 82.56W; Dual AC: 92.53W; Dual DC: 90.28W |
| Power supply — PSR450-12A | 450W AC Power Supply Module (Power Panel Side Intake Airflow) |
| Power supply — PSR450-12A1 | 450W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — PSR450-12AHD | 450W HVDC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — PSR450-12D | 450W DC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — UN-GW-CRPS800N2 | 800W AC & 240V HVDC Power Supply(GW-R2-Platinum-Light Load and High Efficiency)(CTO&BTO) |
| Power supply — UN-GW-CRPS800N2-1 | 800W AC &240V HVDC Power Supply (GW-R2-Platinum-Light Load and High Efficiency)(Excluding Cables)(CTO&BTO) |
| Product code — LS-6550X-32H-HI | H3C S6550X-32H-HI L3 Ethernet Switch with 32*QSFP28 Ports and 1*Slot. Without Power Supplies |
| Product code — LS-6550X-32Q-HI | H3C S6550X-32Q-HI L3 Ethernet Switch with 28*QSFP Plus Ports,4*QSFP28 Ports and 1*Slot. Without Power Supplies |
| Product code — LS-6550X-54H-HI | H3C S6550X-54H-HI L3 Ethernet Switch with 54*40G/100G QSFP28 Ports,Without Power Supplies |
| Product code — LS-6550X-56HF-HI | H3C S6550X-56HF-HI L3 Ethernet Switch with 48*SFP28 Ports,8*QSFP28 Ports and 1*Slot. Without Power Supplies |
| QoS/ACL | Inbound and outbound traffic rate limit; CAR; Eight output queues on each port; Flexible port-and queue-based queuing and scheduling algorithms; SP, WRR, and SP+WRR queuing; 802.1p and DSCP priority re-marking; Packet filtering at Layer 2 to Layer 4; Traffic classification based on source MAC address, destination MAC address, source IPv4/IPv6 address, destination IPv4/IPv6 address, port number, protocol type, and VLAN; Time range; Inbound and outbound ACLs; VLAN-based ACL assignment |
| Safety | UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1, EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter JGB4943.1 |
| Security | Hierarchical user management and password protection; AAA/RADIUS/HWTACACS; SSH 2.0; IP address + MAC address + port number binding; IP Source Guard; HTTPs/SSL; PKI; 802.1X; MAC authentication; EAD; IPv6 RADIUS Sever; IPv6 port binding |
| Traffic monitoring | sFlow |
| Transceivers — QSFP-100G-4SFP-25G-CAB-1M | 100G QSFP28 to 4x25G SFP28 1m Passive Cable |
| Transceivers — QSFP-100G-4SFP-25G-CAB-3M | 100G QSFP28 to 4x25G SFP28 3m Passive Cable |
| Transceivers — QSFP-100G-4SFP-25G-CAB-5M | 100G QSFP28 to 4x25G SFP28 5m Passive Cable |
| Transceivers — QSFP-100G-D-AOC-10M | 100G QSFP28 to 100G QSFP28 10m Active Optical Cable |
| Transceivers — QSFP-100G-D-AOC-20M | 100G QSFP28 to 100G QSFP28 20m Active Optical Cable |
| Transceivers — QSFP-100G-D-AOC-7M | 100G QSFP28 to 100G QSFP28 7m Active Optical Cable |
| Transceivers — QSFP-100G-D-CAB-1M | 100G QSFP28 to 100G QSFP28 1m Passive Cable |
| Transceivers — QSFP-100G-D-CAB-3M | 100G QSFP28 to 100G QSFP28 3m Passive Cable |
| Transceivers — QSFP-100G-D-CAB-5M | 100G QSFP28 to 100G QSFP28 5m Passive Cable |
| Transceivers — QSFP-100G-LR4-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,10km, LR4, WDM, LC) |
| Transceivers — QSFP-100G-LR4L-WDM1300 | 100G QSFP28 Optical Transceiver Module (1310nm,2km, LR4L, CWDM4, LC) |
| Transceivers — QSFP-100G-SR4-MM850 | 100G QSFP28 Optical Transceiver Module (850nm,100m OM4, SR4, MPO) |
| Transceivers — QSFP-40G-BIDI-SR-MM850 | QSFP+ 40GBASE BIDI Optical Transceiver Module (850nm,100m, SR) |
| Transceivers — QSFP-40G-BIDI-WDM850 | QSFP+ 40GBASE BIDI Optical Transceiver Module (850nm,300m) |
| Transceivers — QSFP-40G-D-AOC-10M | 40G QSFP+ to 40G QSFP+ 10m Active Optical Cable |
| Transceivers — QSFP-40G-D-AOC-20M | 40G QSFP+ to 40G QSFP+ 20m Active Optical Cable |
| Transceivers — QSFP-40G-D-AOC-7M | 40G QSFP+ to 40G QSFP+ 7m Active Optical Cable |
| Transceivers — QSFP-40G-LR4-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,10km, LR4, LC) |
| Transceivers — QSFP-40G-LR4L-WDM1300 | QSFP+ 40GBASE Optical Transceiver Module (1310nm,2km, LR4L, LC) |
| Transceivers — QSFP-40G-SR4-MM850 | QSFP+ 40GBASE Optical Transceiver Module (850nm,100m, SR4, Support 40G to 4*10G) |
| Virtualization | Intelligent Resilient Framework 2 (IRF2) (fast convergence within 50ms); Distributed device management; Distributed link aggregation; Distributed resilient routing; Stacking through standard Ethernet ports; Local device stacking and remote device stacking |
| VLAN | Port-based VLAN; Default VLAN |
| VLAN interface | 1K |
| Weight(Full loaded) | ≤ 9kg |
| Zero-configuration | Auto-config |
Points to check before using S6550X-HI in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| AC input voltage | 100V to 240V |
| DC Input Voltage | 48V to 64V |
| Power consumption (at full load) | Single AC: 390.5W; Single DC: 410.1W; Dual AC: 386.3W; Dual DC: 404.2W |
| Power consumption (static) | Single AC: 81.54W; Single DC: 82.56W; Dual AC: 92.53W; Dual DC: 90.28W |
| Power supply — PSR450-12A | 450W AC Power Supply Module (Power Panel Side Intake Airflow) |
| Power supply — PSR450-12A1 | 450W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — PSR450-12AHD | 450W HVDC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — PSR450-12D | 450W DC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Power supply — UN-GW-CRPS800N2 | 800W AC & 240V HVDC Power Supply(GW-R2-Platinum-Light Load and High Efficiency)(CTO&BTO) |
| Power supply — UN-GW-CRPS800N2-1 | 800W AC &240V HVDC Power Supply (GW-R2-Platinum-Light Load and High Efficiency)(Excluding Cables)(CTO&BTO) |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of S6550X-HI can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Safety": UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1, EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter JGB4943.1.
Yes — recorded under "Product code — LS-6550X-32H-HI": H3C S6550X-32H-HI L3 Ethernet Switch with 32*QSFP28 Ports and 1*Slot. Without Power Supplies.
Yes — recorded under "Management and maintenance": Configuration via CLI, Telnet, and Console port; SNMPv1/v2c/v3; Telemetry; gRPC; PTP; IMC; System logs; Hierarchical alarms; NTP, SNTP; Power, fan and temperature alarms; Debugging information output; Ping and Tracert; File uploading and downloading through the USB port.
-5~45°C (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
High-Density 40G/100G Layer 3 Switch for Data Centers

30 Port SFP+ Layer 3 Managed Industrial Ethernet Switch

Layer 3 10GBASE-X SFP+ + 4-Port 10GBASE-T Managed Ethernet Switch

L3 100/1G SFP with 4 shared 10/100/1000T + 10-Port 1G/2.5G SFP + 4-Port 10G SFP+ Metro Ethernet Switch

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | S6550X-HI |
| Manufacturer | H3C |
Core and Aggregation Switches
Gigabit Managed Layer 3 Switch with 4 SFP Ports · Ref. : DGS-3312SR
Price on request
Core and Aggregation Switches
24-port Layer 3 PoE+ switch with 2.5 GbE and 10G SFP+ · Ref. : USW-ENTERPRISE-24-POE
Price on request
Core and Aggregation Switches
IP65 high bay dual sense presence sensor HF and PIR · Ref. : HIM30-B-L2
Price on request
Core and Aggregation Switches
28-port GbE L3 aggregation switch with 4 SFP+ uplinks
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details