S6850
High-density 25GE data center switch

- Operating Temperature
- 0-45℃(32°F to 113°F)
- Interface — IPv4 tunnel number
- 2K
- Interface — IPv6 tunnel number
- 2K
- Interface — Loopback interface number
- 1K
High-density 25GE data center switch
The H3C S6850 is a high-density switch for data centers and cloud computing networks, with up to 48 x 25G SFP28 ports and 8 x 100G QSFP28 ports.
Overview. The H3C S6850 is a high-density data center switch series designed for data center and cloud computing networks. It can operate as a TOR access switch on an overlay or integrated network. Ports and capacity — The series includes the S6850-56HF, with 48 x 25G SFP28 ports (autosensing down to 10GE/1GE) and 8 x 100G QSFP28 ports, and the S6850-2C, with 2 service slots and 2 x 100G QSFP28 ports. The switch offers a wire-speed capacity of up to 4 Tbps and a forwarding capacity of 2024 Mpps. Virtualization — IRF2 technology virtualizes multiple devices into one logical device, with improved scalability and availability within a rack, across racks or across regions. Data center features — The switch supports VXLAN, MP-BGP EVPN as VXLAN control plane, FCoE, Priority-based Flow Control (PFC) and Enhanced Transmission Selection. Power and cooling — The switch supports redundant, hot-swappable power supplies and fans. Fan trays allow the airflow direction to be changed, from front to rear or from rear to front. The minimum operating temperature is 0 °C. Standards — The switch implements numerous IEEE standards, including 802.1Q, 802.1AX (link aggregation), 802.1AB, 802.1Qbb and 802.1Qaz, 802.1AS and 1588-2008 for time synchronization, 802.3ad and 802.3ae. Availability — Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for S6850, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| AC input voltage | 90v AC to 264v AC |
| ACL — max number of egress Car | 1K |
| ACL — max number of egress Counter | 1K |
| ACL — max number of ingress ACL | 18K/pipe, total 2 pipes |
| ACL — max number of ingress Car | 2304/pipe, total 2 pipes |
| ACL — max number of ingress Counter | 10752/pipe, total 2 pipes |
| Air flow direction | From front to rear or from rear to front |
| Buffer(byte) | 32M |
| CPU | C3000,2.2GHz@4Core |
| DC Input Voltage | 190v DC to 310v DC |
| Device virtualization | IRF2.0 |
| Dimensions H*W*D | Without package: 44 × 440 × 400 mm (1.73 × 17.32 × 15.75 in); With package: 150 × 658 × 556 mm (5.91 × 25.91 × 21.89 in) |
| Fan tray slot | 4 Hot-swappable fan, fan speed adjustable and wind invertible |
| FC/FOCE | FC, FC subcard is supported on S6850-2C |
| Flash/SDRAM | 4GB/8GB |
| Forwarding Capacity | 2024 Mpps |
| Forwarding table — BGP peer number | 1K |
| Forwarding table — BGP routing table | 32K min/324K max |
| Forwarding table — ECMP group | max 4K |
| Forwarding table — ECMP member per group | 2-128 |
| Forwarding table — IPv4 multicast routing | 128K |
| Forwarding table — IPv6 multicast routing | 64K |
| Forwarding table — ISIS peer number | 1K |
| Forwarding table — ISIS routing table | 32K min/324K max |
| Forwarding table — max ND table size for IPv6 | 136K max |
| Forwarding table — max number of ARP entries IPv4 | 272K max |
| Forwarding table — max number of MAC per switch | 288K max |
| Forwarding table — max number of unicast routes IPv4 | *350K max |
| Forwarding table — max number of unicast routes IPv6 | 262K max |
| Forwarding table — OSPF peer number | 1K |
| Forwarding table — OSPF routing table | 32K min/324K max |
| IEEE — 1588-2008 | Timing and Synchronization for Time-Sensitive Applications in Bridged Local Area Networks |
| IEEE — 802.1 | LAN/MAN Bridge and Management |
| IEEE — 802.11-2007 | Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) specification |
| IEEE — 802.11a-1999 | High-speed Physical Layer in the 5GHz Band |
| IEEE 802.11ac | Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications; Amendment 4: Enhancements for Very High Throughput for Operation in Bands below 6 GHz |
| IEEE — 802.11b-1999 | High-speed Physical Layer Extension in the 2.4GHz Band |
| IEEE — 802.11d-1999 | Specifiation for operation in additional regulatory domain |
| IEEE — 802.11g-2003 | Further High Data Rate Extension in the 2.4GHz Band |
| IEEE — 802.11h-2003 | Spectrum and Transmit Power Management externsion in the 5GHz Band in Europe |
| IEEE — 802.11i-2004 | Wi-Fi Protected Access |
| IEEE — 802.11k | Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications; Amendment 1: Radio Resource Measurement of Wireless LANs |
| IEEE 802.11n | Enhancements for Higher Throughput |
| IEEE — 802.11r | Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications; Amendment 2: Fast Basic Service Set (BSS) Transition |
| IEEE — 802.11s | Wireless Medium Access Control (MAC) and physical layer (PHY) specifications: Amendment: ESS Mesh Networking |
| IEEE — 802.11u | Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) specifications; Amendment 7: Interworking with External Networks |
| IEEE — 802.11w | Wireless Medium Access Control (MAC) and physical layer (PHY) specifications Ammendment-w: Protected Management Frames |
| IEEE — 802.17-2011 | Part 17: Resilient packet ring (RPR) access method and physical layer specifications |
| IEEE — 802.1AB-2005 | IEEE Standard for Local and metropolitan area networks Station and Media Access Control Connectivity Discovery |
| IEEE — 802.1AB-2009 | IEEE Standard for Local and metropolitan area networks Station and Media Access Control Connectivity Discovery |
| IEEE — 802.1ad-2005 | Virtual Bridged Local Area Networks |
| IEEE — 802.1AE-2006 | IEEE Standard for Local and metropolitan area networks—Port-Based Network Access Control Part 9:MACsec Key Agreement protocol (MKA) |
| IEEE — 802.1ag-2007 | Virtual Bridged Local Area Networks Amendment 5: Connectivity Fault Management |
| IEEE — 802.1ah-2008 | Virtual Bridged Local Area Networks—Amendment 6: Provider Backbone Bridges |
| IEEE — 802.1ak-2007 | Virtual Bridged Local Area Networks—Amendment 7: Multiple Registration Protocol |
| IEEE — 802.1AS-2011 | Timing and Synchronization for Time-Sensitive Applications in Bridged Local Area Networks |
| IEEE — 802.1AX-2008 | Link Aggregation |
| IEEE — 802.1br | Bridge Port Extension |
| IEEE — 802.1D-2004 | Media Access Control (MAC) Bridges |
| IEEE — 802.1p | Traffic Class Expediting and Dynamic Multicast Filtering |
| IEEE — 802.1Q-2005 | Virtual Bridged Local Area Networks |
| IEEE — 802.1Q-2011 | IEEE Standard for Local and metropolitan area networks——Media Access Control (MAC) Bridges and Virtual Bridge Local Area Networks |
| IEEE — 802.1Qaz-2011 | Draft Standard for Local and Metropolitan Area Networks Virtual Bridged Local Area Networks Amendment 18: Enhanced Transmission Selection for Bandwidth Sharing Between Traffic Classes |
| IEEE — 802.1Qbb-2011 | Media Access Control (MAC) Bridges and Virtual Bridged Local Area Networks—Amendment 17: Priority-based Flow Control |
| IEEE — 802.1s-2002 | Virtual Bridged Local Area Networks—Amendment 3: Multiple Spanning Tree |
| IEEE — 802.1t-2001 | Part 3: Media Access Control (MAC) Bridges—Amendment 1 |
| IEEE — 802.1v-2001 | Virtual Bridged Local Area Networks—Amendment 2: VLAN Classification by Protocol and Port |
| IEEE — 802.1w-2001 | Part 3:Media Access Control (MAC) Bridges—Amendment 2: Rapid Reconfiguration |
| IEEE — 802.1X-2001 | Standard for Port based Network Access Control |
| IEEE — 802.1X-2010 | IEEE Standard for Local and metropolitan area networks—Port-Based Network Access Control Part 9:MACsec Key Agreement protocol (MKA) |
| IEEE — 802.2 | Logical Link Control |
| IEEE — 802.3 | Carrier Sense Multiple Access with Collision Detection (CSMA/CD) access method and physical layer specifications |
| IEEE — 802.3ab | 1000BASE-T Gbit/s Ethernet over twisted pair at 1 Gbit/s (125 MB/s) |
| IEEE — 802.3ad-2000 | Link Aggregation Control Protocol |
| IEEE — 802.3ae | Amendment 1:Media Access Control(MAC)Parameters, Physical Layers, and Management Parameters for 10 Gb/s Operation |
| IEEE — 802.3ah-2004 | IEEE Standard for; Operations, Administration, and Maintenance (OAM) |
| IEEE — 802.3z | 1000BASE-X Gbit/s Ethernet over Fiber-Optic at 1 Gbit/s (125 MB/s) |
| IETF — RFC0768 | User Datagram Protocol |
| IETF — RFC0791 | Internet Protocol |
| IETF — RFC0792 | Internet Standard Subnetting Procedure |
| IETF — RFC0793 | Transmission Control Protocol |
| IETF — RFC0826 | Ethernet Address Resolution Protocol: Or Converting Network Protocol Addresses to 48.bit Ethernet Address for Transmission on Ethernet Hardware |
| IETF — RFC0854 | Telnet Protocol Specification |
| IETF — RFC0855 | Telnet Option Specifications |
| IETF — RFC0856 | Telnet Binary Transmission |
| IETF — RFC0857 | Telnet Echo Option |
| IETF — RFC0858 | Telnet Suppress Go Ahead Option |
| IETF — RFC0862 | Character Generator Protocol |
| IETF — RFC0864 | Character Generator Protocol |
| IETF — RFC0894 | A Standard for the Transmission of IP Datagrams over Ethernet Networks |
| IETF — RFC0919 | Broadcasting Internet Datagrams |
| IETF — RFC0922 | Broadcasting Internet Datagrams in the Presence of Subnets (IP_BROAD) |
| IETF — RFC0950 | Internet Standard Subnetting Procedure |
| IETF — RFC0959 | FILE TRANSFER PROTOCOL (FTP) |
| IETF — RFC1034 | Domain names - implementation and specification |
| IETF — RFC1035 | Domain names - implementation and specification |
| IETF — RFC1112 | Host Extensions for IP Multicasting |
| IETF — RFC1119 | Network Time Protocol (version 2) specification and implementation |
| IETF — RFC1122 | Requirements for Internet Hosts - Communication Layers |
| IETF — RFC1155 | Structure and identification of management information for TCP/IP-based internets |
| IETF — RFC1212 | Concise MIB definitions. |
| IETF — RFC1213 | RADIUS Accounting |
| IETF — RFC1350 | Trivial File Transfer Protocol(TFTP). |
| IETF — RFC1661 | The Point-to-Point Protocol (PPP) |
| IETF — RFC1662 | PPP in HDLC-like Framing |
| IETF — RFC1722 | RIP Version 2 Protocol Applicability Statement |
| Interface — IPv4 tunnel number | 2K |
| Interface — IPv6 tunnel number | 2K |
| Interface — Loopback interface number | 1K |
| Interface — SVI interface number | 4K |
| Interface — VSI interface number | 8K |
| Interface — VxLAN AC number | 16K |
| Interface — VxLAN tunnel number | 2K |
| Interface — VxLAN VSI number | 16K |
| IPv4 routing | Static routing and default routing |
| IPv6 routing | Static routing and default routing |
| Latency | Port-to-Port minimum: about 550ns |
| Lossless network | PFC and ECN |
| MAC Address | Dynamic learning and aging of mac address entries |
| Maximum power consumption; (Fully configured with transceiver modules, at 100% load) | Single AC input: 424 W; Dual AC inputs: 429 W |
| Maximum thermal consumption | 1464 BTU/hr |
| MPLS/VPLS | Support L3 MPLS VPN |
| MTBF(year) | 78.7 |
| MTTR [hour] | 0.5 |
| Multicast | IGMP snooping |
| Network virtualization | BGP-EVPN |
| Operating Humidity | 5% to 95%, noncondensing |
| Operating Temperature | 0-45℃(32°F to 113°F) |
| Organization — ID | Standards And Protocols |
| Out-of-band management port | 1 ×10/100/1000BASE-T |
| Performance — RIB | 1M |
| PID | LS-6850-56HF-H3 |
| Programmability | Openflow1.3 |
| QoS | Weighted Random Early Detection (WRED) and tail drop |
| Reliability | LACP |
| SDN | H3C SeerEngine-DC |
| Security and management | Authentication methods, including AAA,RADIUS and HWTACACS |
| Serial console port | RJ45 |
| Static table — static ARP | 1K |
| Static table — static IPv4 routing table | 4K |
| Static table — static IPv6 routing table | 2K |
| Static table — static multicast mac-address | 1K |
| Static table — static ND | 4K |
| Switching Capacity | 4 Tbps |
| Telemetry | gRPC |
| Traffic analysis | Sflow |
| Typical power consumption; (Fully configured with copper cables, at 50% load) | Single AC input: 143 W; Dual AC inputs: 150 W |
| VLAN | Port-based VLANs |
| VXLAN | L2 VxLAN gateway |
| Weight | ≤ 10 kg (22.05 lb) |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for S6850. For a missing document or a specific revision, our experts send it to you.
The H3C S6850 is a high-density switch for data centers and cloud computing networks, with up to 48 x 25G SFP28 ports and 8 x 100G QSFP28 ports.
| Parameter | Value |
|---|---|
| AC input voltage | 90v AC to 264v AC |
| ACL — max number of egress Car | 1K |
| ACL — max number of egress Counter | 1K |
| ACL — max number of ingress ACL | 18K/pipe, total 2 pipes |
| ACL — max number of ingress Car | 2304/pipe, total 2 pipes |
| ACL — max number of ingress Counter | 10752/pipe, total 2 pipes |
| Air flow direction | From front to rear or from rear to front |
| Buffer(byte) | 32M |
| CPU | C3000,2.2GHz@4Core |
| DC Input Voltage | 190v DC to 310v DC |
| Device virtualization | IRF2.0 |
| Dimensions H*W*D | Without package: 44 × 440 × 400 mm (1.73 × 17.32 × 15.75 in); With package: 150 × 658 × 556 mm (5.91 × 25.91 × 21.89 in) |
| Fan tray slot | 4 Hot-swappable fan, fan speed adjustable and wind invertible |
| FC/FOCE | FC, FC subcard is supported on S6850-2C |
| Flash/SDRAM | 4GB/8GB |
| Forwarding Capacity | 2024 Mpps |
| Forwarding table — BGP peer number | 1K |
| Forwarding table — BGP routing table | 32K min/324K max |
| Forwarding table — ECMP group | max 4K |
| Forwarding table — ECMP member per group | 2-128 |
| Forwarding table — IPv4 multicast routing | 128K |
| Forwarding table — IPv6 multicast routing | 64K |
| Forwarding table — ISIS peer number | 1K |
| Forwarding table — ISIS routing table | 32K min/324K max |
| Forwarding table — max ND table size for IPv6 | 136K max |
| Forwarding table — max number of ARP entries IPv4 | 272K max |
| Forwarding table — max number of MAC per switch | 288K max |
| Forwarding table — max number of unicast routes IPv4 | *350K max |
| Forwarding table — max number of unicast routes IPv6 | 262K max |
| Forwarding table — OSPF peer number | 1K |
| Forwarding table — OSPF routing table | 32K min/324K max |
| IEEE — 1588-2008 | Timing and Synchronization for Time-Sensitive Applications in Bridged Local Area Networks |
| IEEE — 802.1 | LAN/MAN Bridge and Management |
| IEEE — 802.11-2007 | Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) specification |
| IEEE — 802.11a-1999 | High-speed Physical Layer in the 5GHz Band |
| IEEE 802.11ac | Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications; Amendment 4: Enhancements for Very High Throughput for Operation in Bands below 6 GHz |
| IEEE — 802.11b-1999 | High-speed Physical Layer Extension in the 2.4GHz Band |
| IEEE — 802.11d-1999 | Specifiation for operation in additional regulatory domain |
| IEEE — 802.11g-2003 | Further High Data Rate Extension in the 2.4GHz Band |
| IEEE — 802.11h-2003 | Spectrum and Transmit Power Management externsion in the 5GHz Band in Europe |
| IEEE — 802.11i-2004 | Wi-Fi Protected Access |
| IEEE — 802.11k | Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications; Amendment 1: Radio Resource Measurement of Wireless LANs |
| IEEE 802.11n | Enhancements for Higher Throughput |
| IEEE — 802.11r | Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications; Amendment 2: Fast Basic Service Set (BSS) Transition |
| IEEE — 802.11s | Wireless Medium Access Control (MAC) and physical layer (PHY) specifications: Amendment: ESS Mesh Networking |
| IEEE — 802.11u | Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) specifications; Amendment 7: Interworking with External Networks |
| IEEE — 802.11w | Wireless Medium Access Control (MAC) and physical layer (PHY) specifications Ammendment-w: Protected Management Frames |
| IEEE — 802.17-2011 | Part 17: Resilient packet ring (RPR) access method and physical layer specifications |
| IEEE — 802.1AB-2005 | IEEE Standard for Local and metropolitan area networks Station and Media Access Control Connectivity Discovery |
| IEEE — 802.1AB-2009 | IEEE Standard for Local and metropolitan area networks Station and Media Access Control Connectivity Discovery |
| IEEE — 802.1ad-2005 | Virtual Bridged Local Area Networks |
| IEEE — 802.1AE-2006 | IEEE Standard for Local and metropolitan area networks—Port-Based Network Access Control Part 9:MACsec Key Agreement protocol (MKA) |
| IEEE — 802.1ag-2007 | Virtual Bridged Local Area Networks Amendment 5: Connectivity Fault Management |
| IEEE — 802.1ah-2008 | Virtual Bridged Local Area Networks—Amendment 6: Provider Backbone Bridges |
| IEEE — 802.1ak-2007 | Virtual Bridged Local Area Networks—Amendment 7: Multiple Registration Protocol |
| IEEE — 802.1AS-2011 | Timing and Synchronization for Time-Sensitive Applications in Bridged Local Area Networks |
| IEEE — 802.1AX-2008 | Link Aggregation |
| IEEE — 802.1br | Bridge Port Extension |
| IEEE — 802.1D-2004 | Media Access Control (MAC) Bridges |
| IEEE — 802.1p | Traffic Class Expediting and Dynamic Multicast Filtering |
| IEEE — 802.1Q-2005 | Virtual Bridged Local Area Networks |
| IEEE — 802.1Q-2011 | IEEE Standard for Local and metropolitan area networks——Media Access Control (MAC) Bridges and Virtual Bridge Local Area Networks |
| IEEE — 802.1Qaz-2011 | Draft Standard for Local and Metropolitan Area Networks Virtual Bridged Local Area Networks Amendment 18: Enhanced Transmission Selection for Bandwidth Sharing Between Traffic Classes |
| IEEE — 802.1Qbb-2011 | Media Access Control (MAC) Bridges and Virtual Bridged Local Area Networks—Amendment 17: Priority-based Flow Control |
| IEEE — 802.1s-2002 | Virtual Bridged Local Area Networks—Amendment 3: Multiple Spanning Tree |
| IEEE — 802.1t-2001 | Part 3: Media Access Control (MAC) Bridges—Amendment 1 |
| IEEE — 802.1v-2001 | Virtual Bridged Local Area Networks—Amendment 2: VLAN Classification by Protocol and Port |
| IEEE — 802.1w-2001 | Part 3:Media Access Control (MAC) Bridges—Amendment 2: Rapid Reconfiguration |
| IEEE — 802.1X-2001 | Standard for Port based Network Access Control |
| IEEE — 802.1X-2010 | IEEE Standard for Local and metropolitan area networks—Port-Based Network Access Control Part 9:MACsec Key Agreement protocol (MKA) |
| IEEE — 802.2 | Logical Link Control |
| IEEE — 802.3 | Carrier Sense Multiple Access with Collision Detection (CSMA/CD) access method and physical layer specifications |
| IEEE — 802.3ab | 1000BASE-T Gbit/s Ethernet over twisted pair at 1 Gbit/s (125 MB/s) |
| IEEE — 802.3ad-2000 | Link Aggregation Control Protocol |
| IEEE — 802.3ae | Amendment 1:Media Access Control(MAC)Parameters, Physical Layers, and Management Parameters for 10 Gb/s Operation |
| IEEE — 802.3ah-2004 | IEEE Standard for; Operations, Administration, and Maintenance (OAM) |
| IEEE — 802.3z | 1000BASE-X Gbit/s Ethernet over Fiber-Optic at 1 Gbit/s (125 MB/s) |
| IETF — RFC0768 | User Datagram Protocol |
| IETF — RFC0791 | Internet Protocol |
| IETF — RFC0792 | Internet Standard Subnetting Procedure |
| IETF — RFC0793 | Transmission Control Protocol |
| IETF — RFC0826 | Ethernet Address Resolution Protocol: Or Converting Network Protocol Addresses to 48.bit Ethernet Address for Transmission on Ethernet Hardware |
| IETF — RFC0854 | Telnet Protocol Specification |
| IETF — RFC0855 | Telnet Option Specifications |
| IETF — RFC0856 | Telnet Binary Transmission |
| IETF — RFC0857 | Telnet Echo Option |
| IETF — RFC0858 | Telnet Suppress Go Ahead Option |
| IETF — RFC0862 | Character Generator Protocol |
| IETF — RFC0864 | Character Generator Protocol |
| IETF — RFC0894 | A Standard for the Transmission of IP Datagrams over Ethernet Networks |
| IETF — RFC0919 | Broadcasting Internet Datagrams |
| IETF — RFC0922 | Broadcasting Internet Datagrams in the Presence of Subnets (IP_BROAD) |
| IETF — RFC0950 | Internet Standard Subnetting Procedure |
| IETF — RFC0959 | FILE TRANSFER PROTOCOL (FTP) |
| IETF — RFC1034 | Domain names - implementation and specification |
| IETF — RFC1035 | Domain names - implementation and specification |
| IETF — RFC1112 | Host Extensions for IP Multicasting |
| IETF — RFC1119 | Network Time Protocol (version 2) specification and implementation |
| IETF — RFC1122 | Requirements for Internet Hosts - Communication Layers |
| IETF — RFC1155 | Structure and identification of management information for TCP/IP-based internets |
| IETF — RFC1212 | Concise MIB definitions. |
| IETF — RFC1213 | RADIUS Accounting |
| IETF — RFC1350 | Trivial File Transfer Protocol(TFTP). |
| IETF — RFC1661 | The Point-to-Point Protocol (PPP) |
| IETF — RFC1662 | PPP in HDLC-like Framing |
| IETF — RFC1722 | RIP Version 2 Protocol Applicability Statement |
| Interface — IPv4 tunnel number | 2K |
| Interface — IPv6 tunnel number | 2K |
| Interface — Loopback interface number | 1K |
| Interface — SVI interface number | 4K |
| Interface — VSI interface number | 8K |
| Interface — VxLAN AC number | 16K |
| Interface — VxLAN tunnel number | 2K |
| Interface — VxLAN VSI number | 16K |
| IPv4 routing | Static routing and default routing |
| IPv6 routing | Static routing and default routing |
| Latency | Port-to-Port minimum: about 550ns |
| Lossless network | PFC and ECN |
| MAC Address | Dynamic learning and aging of mac address entries |
| Maximum power consumption; (Fully configured with transceiver modules, at 100% load) | Single AC input: 424 W; Dual AC inputs: 429 W |
| Maximum thermal consumption | 1464 BTU/hr |
| MPLS/VPLS | Support L3 MPLS VPN |
| MTBF(year) | 78.7 |
| MTTR [hour] | 0.5 |
| Multicast | IGMP snooping |
| Network virtualization | BGP-EVPN |
| Operating Humidity | 5% to 95%, noncondensing |
| Operating Temperature | 0-45℃(32°F to 113°F) |
| Organization — ID | Standards And Protocols |
| Out-of-band management port | 1 ×10/100/1000BASE-T |
| Performance — RIB | 1M |
| PID | LS-6850-56HF-H3 |
| Programmability | Openflow1.3 |
| QoS | Weighted Random Early Detection (WRED) and tail drop |
| Reliability | LACP |
| SDN | H3C SeerEngine-DC |
| Security and management | Authentication methods, including AAA,RADIUS and HWTACACS |
| Serial console port | RJ45 |
| Static table — static ARP | 1K |
| Static table — static IPv4 routing table | 4K |
| Static table — static IPv6 routing table | 2K |
| Static table — static multicast mac-address | 1K |
| Static table — static ND | 4K |
| Switching Capacity | 4 Tbps |
| Telemetry | gRPC |
| Traffic analysis | Sflow |
| Typical power consumption; (Fully configured with copper cables, at 50% load) | Single AC input: 143 W; Dual AC inputs: 150 W |
| VLAN | Port-based VLANs |
| VXLAN | L2 VxLAN gateway |
| Weight | ≤ 10 kg (22.05 lb) |
Points to check before using S6850 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| AC input voltage | 90v AC to 264v AC |
| DC Input Voltage | 190v DC to 310v DC |
| Maximum power consumption; (Fully configured with transceiver modules, at 100% load) | Single AC input: 424 W; Dual AC inputs: 429 W |
| Maximum thermal consumption | 1464 BTU/hr |
| Typical power consumption; (Fully configured with copper cables, at 50% load) | Single AC input: 143 W; Dual AC inputs: 150 W |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of S6850 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "IEEE — 802.11i-2004": Wi-Fi Protected Access.
Yes — recorded under "IEEE — 802.3ab": 1000BASE-T Gbit/s Ethernet over twisted pair at 1 Gbit/s (125 MB/s).
0-45℃(32°F to 113°F) (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
High-density 25GE data center switch

GbE L2+ Managed Switch

12 Port Gigabit Layer 2 Managed Industrial PoE++ Switch

10 Port or 12 Port 2.5 Gigabit Layer 2 Managed PoE Switch

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | S6850 |
| Manufacturer | H3C |
Campus Access Switches
Fully managed 48-port 1G PoE+ switch with 2 10G and 2 SFP+ ports · Ref. : GSM4352PB
Price on request
Campus Access Switches
Industrial Gigabit managed PoE switch with SFP ports · Ref. : DIS-300G-8PSW
Price on request
Campus Access Switches
Layer 2 PoE campus access switch, 5 ports
Price on request
Campus Access Switches
Multi-gigabit managed switch with 8x 2.5G ports and 10G SFP+ ports · Ref. : GWN7721
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details