S9825-G
800GE/400GE/200GE high-density data center switch

- Operating Temperature
- 0ºC~40ºC
- Interface
- 8K
- AC input voltage
- 100V-240V AC;50/60Hz
- DC Input Voltage
- 240V DC
800GE/400GE/200GE high-density data center switch
The H3C S9825-G is a high-density L3 Ethernet switch for data centers, with 800GE, 400GE and 200GE ports, designed for next-generation data center core networks.
Overview. The H3C S9825-G data center switch is an L3 Ethernet core and aggregation switch designed for next-generation data center networks. The series includes two models, the S9825-8C-G with 8 interface module slots and the S9825-64DH-G with 64 QSFP112 100G/200G/400G ports.
Main characteristics. The switch offers a switching capacity of 51.2T bidirectional, a forwarding capacity of 11.2Bpps and a latency of 1μs. It provides 96K static table entries, 8K interface entries, 16G of RAM and 128G of SSD storage. The out-of-band management port includes one 10M/100M/1000M Base-T port and three SFP ports.
Interfaces and connectivity. Available interface modules are 8-port 400G QSFP112, 4-port 400G QSFP-DD, 2-port 800G QSFP-DD, 4-port 800G QSFP-DD, 16-port 200G QSFP56 and 8-port 200G QSFP56. The switch supports 802.3ad link aggregation, static, dynamic and Layer 3 aggregation, and M-LAG according to IEEE P802.1AX-REV/D4.4c. Management is available through console, Telnet, SSH, SNMPv1/v2/v3 and ZTP.
Routing and multicast. IPv4 and IPv6 routing covers static routing, RIP, OSPF, IS-IS, BGP and BGP4+, with VRRP and PBR. The switch supports MPLS, L3VPN, L2VPN, VXLAN, and the IGMP and MLD snooping, PIM and MSDP multicast functions.
Monitoring and telemetry. The switch integrates gRPC, ERSPAN, Telemetry Stream, INT, sFlow, NetStream and IPv6 NetStream for traffic analysis and data center monitoring. It is programmable through RESTful, Python, NETCONF, Ansible and OpenFlow.
Power and environment. It operates on 100V-240V AC, 50/60Hz, or 240V DC, with static power consumption of 444W with dual power and 488W with four power supplies. Operating temperatures range from 0ºC to 40ºC and humidity from 5% to 95%. Weight is 45 kg or less, with dimensions of 130.5×440×760 mm. Airflow is fan panel side exhaust.
Integration. The switch supports MACsec and Cloudsec security, lossless PFC and ECN mechanisms for RoCEv2 networks, and high-availability features STP, RSTP, MSTP, ERPS and BFD.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for S9825-G, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| AC input voltage | 100V-240V AC;50/60Hz |
| Air flow direction | Fan Panel Side Exhaust Airflow |
| ARP | RFC1027,RFC4562 |
| BGP | RFC 1700; RFC 1997; RFC 2439; RFC 2545; RFC 2918; RFC 3107; RFC 4271; RFC 4275; RFC 4277; RFC 4360; RFC 4364; RFC 4382; RFC 4451; RFC 4456; RFC 4486; RFC 4659; RFC 4684; RFC 4724; RFC 4760; RFC 4781; RFC 5004; RFC 5065; RFC 5082; RFC 5291; RFC 5292; RFC 5549; RFC 5492; RFC 5668; RFC 6198; RFC 6368; RFC 6513; RFC 6514; RFC 6515; RFC 6624; RFC 6793; RFC 7432; RFC 7752; RFC 7854; RFC 7911; RFC 7947 |
| Buffer | 64MB |
| Configuration and maintenance | Console telnet and SSH terminals; SNMPv1/v2/v3; ZTP |
| CPU | 2.2GHz |
| DC Input Voltage | 240V DC |
| Device virtualization | M-LAG |
| DHCP | RFC 2131; RFC 2132; RFC 1542; RFC 3046; RFC 3442 |
| Dimensions H*W*D (mm) | 130.5×440×760 |
| DNS | RFC1034;RFC1035 |
| Ethernet Link Aggregation Configuration | 802.3ad |
| EVPN | RFC7209,RFC7432;RFC9014;RFC8365;RFC7432;RFC8214 |
| Expansion Slot | 8 slots |
| Fan; Fan — FAN-80B-1-D | Fan Module (Fan Panel Side Exhaust Airflow) |
| Fan; Fan — FAN-80B-1-E | H3C High-Performance Fan Module (8080,Fan Panel Side Exhaust Airflow) |
| Flash/SDRAM | NAND FLASH:SSD 128G; RAM: 16G |
| Forwading table | 1536-13312 |
| Forwarding Capacity | 11.2Bpps |
| FTP/TFTP | RFC 959,RFC 4217,RFC 4253,RFC 1350 |
| gRPC | RFC 7540 |
| Host — S9825-64DH-G | H3C S9825-64DH-G L3 Ethernet Switch with 64*100G/200G/400G QSFP112 Ports |
| Host — S9825-8C-G | H3C S9825-8C-G L3 Ethernet Switch with 8*Interface Module Slots |
| Interface | 8K |
| IPv4 routing | Static routing and default routing; RIP(Routing Information Protocol) v1/2; OSPF (Open Shortest Path First) v1/v2; ISIS(Intermediate System to Intermediate system); BGP (Border Gateway Protocol); Routing policy; VRRP; PBR |
| IPV6 | RFC 1881; RFC 1887; RFC 1981; RFC 2375; RFC 2460; RFC 2464; RFC 2526; RFC 3307; RFC 4191; RFC 4291; RFC 4443; RFC 4862; RFC 4213 |
| IPv6 routing | Static routing and default routing; RIPng; OSPFv3; IPv6 ISIS; BGP4+; Routing policy; VRRP; PBR |
| Latency | 1μs |
| Link aggregation | Static Aggregation; Dynamic Aggregation; Layer 3 Aggregation |
| LLDP | IEEE 802.1AB-2005; IEEE 802.1AB 2009; ANSI/TIA-1057; IEEE Std 802.1Qaz-2011 |
| Lossless network | PFC /PFC deadlock /Deadlock prevention /ECN /AI ECN /ECN OVERLAY /INOF /IPCC; ECMP mode eligibility /ECMP mode enhanced /Spraylink /RoCEv2 flow session analysis; DPSH |
| LSWM1CDHQ8M1 — LSWM1CEQ4M1 | LSWM1CEQ2M1 |
| LSWM1CDQ4M1 — LSWM1CDHQ4M1 | LSWM1CCQ8M1 |
| M-LAG | IEEE P802.1AX-REV™/D4.4c |
| MAC Address | Dynamic learning and aging of mac address entries; Dynamic,static and blackhole entries; Mac address limiting on ports |
| Module — LSWM1CCQ16M1 | H3C 16-Port 200G Ethernet Optical Interface Module(QSFP56) |
| Module — LSWM1CCQ8M1 | H3C 8-Port 200G Ethernet Optical Interface Module (QSFP56) |
| Module — LSWM1CDHQ4M1 | H3C 4-Port 400G Ethernet Optical Interface Module(QSFP112) |
| Module — LSWM1CDHQ8M1 | H3C 8-Port 400G Ethernet Optical Interface Module(QSFP112) |
| Module — LSWM1CDQ4M1 | H3C 4-Port 400G Ethernet Optical Interface Module(QSFP-DD) |
| Module — LSWM1CEQ2M1 | H3C 2-Port 800G Ethernet Optical Interface Module(QSFP-DD) |
| Module — LSWM1CEQ4M1 | H3C 4-Port 800G Ethernet Optical Interface Module(QSFP-DD) |
| MPLS | MPLS; Static LSP; LDP; MPLS L3VPN; MPLS L2VPN; MCE |
| MTBF(years) | 43.8 |
| MTTR [hour] | 0.5 |
| Multicast | IGMP snooping; MLD snooping; IPv4 and IPv6 multicast VLAN; IPv4 and IPv6 PIM snooping; IGMP and MLD; PIM and IPv6 PIM; MSDP; Multicast VPN |
| NetStream | RFC 5101:Specification of the IP Flow Information Export (IPFIX) Protocol for the Exchange of IP Traffic Flow Information |
| Operating Humidity | 5%~95% |
| Operating Temperature | 0ºC~40ºC |
| OSPF | RFC 1245; RFC 1246; RFC 1370; RFC 1403; RFC 1745; RFC 1765; RFC 1793; RFC 2154; RFC 3101; RFC 3166; RFC 3509; RFC 3623; RFC 4167; RFC 4577; RFC 4750; RFC 4811; RFC 4812; RFC 4915; RFC 5088; RFC 5250; RFC 5613; RFC 5642; RFC 5709; RFC 5786; RFC 6571; RFC 6860; RFC 6987 |
| Out-of-band management port | 10M/100M/1000M Base-T port:1; SFP port:3 |
| Performance | 4M |
| Power — PSR2000-12A-S | 2000W AC Power Supply Module(Power Panel Side Exhaust Airflow) |
| Power — PSR2700-12A-A | 2700W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Programmability | RESTful /Tcl /Python /NETCONF /Ansible/OpenFlow |
| QinQ | IEEE 802.1Q; IEEE 802.1ad |
| QoS | RFC 2475;RFC 2597 |
| Reliability | STP/RSTP/MSTP protocol; STP Root Guard and BPDU Guard; ERPS; Ethernet OAM; Smartlink; DLDP; BFD for OSPF/OSPFv3, BGP/BGP4, IS-IS/IS-ISv6, PIM/IPM for IPv6 and Static route; IPv4 VRRP, IPv6 VRRP |
| RIP | RFC 1058; RFC 1723; RFC 1721; RFC 1722; RFC 1724; RFC 2082; RFC 2091 |
| Security and management | Keychain, Public Key Management, PKI, SSH, SSL,; Packet Filtering,; DHCP Snooping, DHCPv6 Snooping; ARP Attack Prevention, ND Attack Prevention, Attack Detection and Prevention, IP Source Guard, uRPF; MACsec,Cloudsec; TCP Attack Prevention Configuration,; Microsegmentation |
| sFlow | RFC3176 |
| Static Power Consumption | Dual power:444W/ Four power:488W |
| Static table | 96K |
| Storage Temperature | -40ºC~70ºC |
| STP | IEEE 802.1D; IEEE 802.1w; IEEE 802.1sIEEE 802.1Q-REV/D1.3 |
| Switching Capacity | 51.2T(bidirection) |
| Telemetry | gRPC; ERSPAN; Telemetry Stream; INT; Ping, Tracert |
| Traffic analysis | Sflow / Netstream / IPv6 NetStream |
| Typical power consumption(full cables, 50% load) | Please refer to hardware document in website |
| Typical power consumption(full transceivers, 100% load) | Please refer to hardware document in website |
| VLAN | Port-based VLANs, Mac-based VLAN, Protocol VLAN; VLAN mapping; QinQ, QinQ Stacking; MVRP(Multiple VLAN Registration Protocol); Super VLAN; PVLAN; Default VLAN |
| VLAN mapping | 802.1ad-2005 |
| VXLAN | L2 VxLAN gateway; L3 VxLAN gateway; Multicast vxlan |
| Weight | ≤45kg |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for S9825-G. For a missing document or a specific revision, our experts send it to you.
The H3C S9825-G is a high-density L3 Ethernet switch for data centers, with 800GE, 400GE and 200GE ports, designed for next-generation data center core networks.
| Parameter | Value |
|---|---|
| AC input voltage | 100V-240V AC;50/60Hz |
| Air flow direction | Fan Panel Side Exhaust Airflow |
| ARP | RFC1027,RFC4562 |
| BGP | RFC 1700; RFC 1997; RFC 2439; RFC 2545; RFC 2918; RFC 3107; RFC 4271; RFC 4275; RFC 4277; RFC 4360; RFC 4364; RFC 4382; RFC 4451; RFC 4456; RFC 4486; RFC 4659; RFC 4684; RFC 4724; RFC 4760; RFC 4781; RFC 5004; RFC 5065; RFC 5082; RFC 5291; RFC 5292; RFC 5549; RFC 5492; RFC 5668; RFC 6198; RFC 6368; RFC 6513; RFC 6514; RFC 6515; RFC 6624; RFC 6793; RFC 7432; RFC 7752; RFC 7854; RFC 7911; RFC 7947 |
| Buffer | 64MB |
| Configuration and maintenance | Console telnet and SSH terminals; SNMPv1/v2/v3; ZTP |
| CPU | 2.2GHz |
| DC Input Voltage | 240V DC |
| Device virtualization | M-LAG |
| DHCP | RFC 2131; RFC 2132; RFC 1542; RFC 3046; RFC 3442 |
| Dimensions H*W*D (mm) | 130.5×440×760 |
| DNS | RFC1034;RFC1035 |
| Ethernet Link Aggregation Configuration | 802.3ad |
| EVPN | RFC7209,RFC7432;RFC9014;RFC8365;RFC7432;RFC8214 |
| Expansion Slot | 8 slots |
| Fan; Fan — FAN-80B-1-D | Fan Module (Fan Panel Side Exhaust Airflow) |
| Fan; Fan — FAN-80B-1-E | H3C High-Performance Fan Module (8080,Fan Panel Side Exhaust Airflow) |
| Flash/SDRAM | NAND FLASH:SSD 128G; RAM: 16G |
| Forwading table | 1536-13312 |
| Forwarding Capacity | 11.2Bpps |
| FTP/TFTP | RFC 959,RFC 4217,RFC 4253,RFC 1350 |
| gRPC | RFC 7540 |
| Host — S9825-64DH-G | H3C S9825-64DH-G L3 Ethernet Switch with 64*100G/200G/400G QSFP112 Ports |
| Host — S9825-8C-G | H3C S9825-8C-G L3 Ethernet Switch with 8*Interface Module Slots |
| Interface | 8K |
| IPv4 routing | Static routing and default routing; RIP(Routing Information Protocol) v1/2; OSPF (Open Shortest Path First) v1/v2; ISIS(Intermediate System to Intermediate system); BGP (Border Gateway Protocol); Routing policy; VRRP; PBR |
| IPV6 | RFC 1881; RFC 1887; RFC 1981; RFC 2375; RFC 2460; RFC 2464; RFC 2526; RFC 3307; RFC 4191; RFC 4291; RFC 4443; RFC 4862; RFC 4213 |
| IPv6 routing | Static routing and default routing; RIPng; OSPFv3; IPv6 ISIS; BGP4+; Routing policy; VRRP; PBR |
| Latency | 1μs |
| Link aggregation | Static Aggregation; Dynamic Aggregation; Layer 3 Aggregation |
| LLDP | IEEE 802.1AB-2005; IEEE 802.1AB 2009; ANSI/TIA-1057; IEEE Std 802.1Qaz-2011 |
| Lossless network | PFC /PFC deadlock /Deadlock prevention /ECN /AI ECN /ECN OVERLAY /INOF /IPCC; ECMP mode eligibility /ECMP mode enhanced /Spraylink /RoCEv2 flow session analysis; DPSH |
| LSWM1CDHQ8M1 — LSWM1CEQ4M1 | LSWM1CEQ2M1 |
| LSWM1CDQ4M1 — LSWM1CDHQ4M1 | LSWM1CCQ8M1 |
| M-LAG | IEEE P802.1AX-REV™/D4.4c |
| MAC Address | Dynamic learning and aging of mac address entries; Dynamic,static and blackhole entries; Mac address limiting on ports |
| Module — LSWM1CCQ16M1 | H3C 16-Port 200G Ethernet Optical Interface Module(QSFP56) |
| Module — LSWM1CCQ8M1 | H3C 8-Port 200G Ethernet Optical Interface Module (QSFP56) |
| Module — LSWM1CDHQ4M1 | H3C 4-Port 400G Ethernet Optical Interface Module(QSFP112) |
| Module — LSWM1CDHQ8M1 | H3C 8-Port 400G Ethernet Optical Interface Module(QSFP112) |
| Module — LSWM1CDQ4M1 | H3C 4-Port 400G Ethernet Optical Interface Module(QSFP-DD) |
| Module — LSWM1CEQ2M1 | H3C 2-Port 800G Ethernet Optical Interface Module(QSFP-DD) |
| Module — LSWM1CEQ4M1 | H3C 4-Port 800G Ethernet Optical Interface Module(QSFP-DD) |
| MPLS | MPLS; Static LSP; LDP; MPLS L3VPN; MPLS L2VPN; MCE |
| MTBF(years) | 43.8 |
| MTTR [hour] | 0.5 |
| Multicast | IGMP snooping; MLD snooping; IPv4 and IPv6 multicast VLAN; IPv4 and IPv6 PIM snooping; IGMP and MLD; PIM and IPv6 PIM; MSDP; Multicast VPN |
| NetStream | RFC 5101:Specification of the IP Flow Information Export (IPFIX) Protocol for the Exchange of IP Traffic Flow Information |
| Operating Humidity | 5%~95% |
| Operating Temperature | 0ºC~40ºC |
| OSPF | RFC 1245; RFC 1246; RFC 1370; RFC 1403; RFC 1745; RFC 1765; RFC 1793; RFC 2154; RFC 3101; RFC 3166; RFC 3509; RFC 3623; RFC 4167; RFC 4577; RFC 4750; RFC 4811; RFC 4812; RFC 4915; RFC 5088; RFC 5250; RFC 5613; RFC 5642; RFC 5709; RFC 5786; RFC 6571; RFC 6860; RFC 6987 |
| Out-of-band management port | 10M/100M/1000M Base-T port:1; SFP port:3 |
| Performance | 4M |
| Power — PSR2000-12A-S | 2000W AC Power Supply Module(Power Panel Side Exhaust Airflow) |
| Power — PSR2700-12A-A | 2700W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Programmability | RESTful /Tcl /Python /NETCONF /Ansible/OpenFlow |
| QinQ | IEEE 802.1Q; IEEE 802.1ad |
| QoS | RFC 2475;RFC 2597 |
| Reliability | STP/RSTP/MSTP protocol; STP Root Guard and BPDU Guard; ERPS; Ethernet OAM; Smartlink; DLDP; BFD for OSPF/OSPFv3, BGP/BGP4, IS-IS/IS-ISv6, PIM/IPM for IPv6 and Static route; IPv4 VRRP, IPv6 VRRP |
| RIP | RFC 1058; RFC 1723; RFC 1721; RFC 1722; RFC 1724; RFC 2082; RFC 2091 |
| Security and management | Keychain, Public Key Management, PKI, SSH, SSL,; Packet Filtering,; DHCP Snooping, DHCPv6 Snooping; ARP Attack Prevention, ND Attack Prevention, Attack Detection and Prevention, IP Source Guard, uRPF; MACsec,Cloudsec; TCP Attack Prevention Configuration,; Microsegmentation |
| sFlow | RFC3176 |
| Static Power Consumption | Dual power:444W/ Four power:488W |
| Static table | 96K |
| Storage Temperature | -40ºC~70ºC |
| STP | IEEE 802.1D; IEEE 802.1w; IEEE 802.1sIEEE 802.1Q-REV/D1.3 |
| Switching Capacity | 51.2T(bidirection) |
| Telemetry | gRPC; ERSPAN; Telemetry Stream; INT; Ping, Tracert |
| Traffic analysis | Sflow / Netstream / IPv6 NetStream |
| Typical power consumption(full cables, 50% load) | Please refer to hardware document in website |
| Typical power consumption(full transceivers, 100% load) | Please refer to hardware document in website |
| VLAN | Port-based VLANs, Mac-based VLAN, Protocol VLAN; VLAN mapping; QinQ, QinQ Stacking; MVRP(Multiple VLAN Registration Protocol); Super VLAN; PVLAN; Default VLAN |
| VLAN mapping | 802.1ad-2005 |
| VXLAN | L2 VxLAN gateway; L3 VxLAN gateway; Multicast vxlan |
| Weight | ≤45kg |
Points to check before using S9825-G in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| AC input voltage | 100V-240V AC;50/60Hz |
| DC Input Voltage | 240V DC |
| Power — PSR2000-12A-S | 2000W AC Power Supply Module(Power Panel Side Exhaust Airflow) |
| Power — PSR2700-12A-A | 2700W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Static Power Consumption | Dual power:444W/ Four power:488W |
| Typical power consumption(full cables, 50% load) | Please refer to hardware document in website |
| Typical power consumption(full transceivers, 100% load) | Please refer to hardware document in website |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of S9825-G can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Ethernet Link Aggregation Configuration": 802.3ad.
0ºC~40ºC (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
800GE/400GE/200GE high-density data center switch

H3C Data Center Switches

30 Port SFP+ Layer 3 Managed Industrial Ethernet Switch

Layer 3 10GBASE-X SFP+ + 4-Port 10GBASE-T Managed Ethernet Switch

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | S9825-G |
| Manufacturer | H3C |
Core and Aggregation Switches
Gigabit Managed Layer 3 Switch with 4 SFP Ports · Ref. : DGS-3312SR
Price on request
Core and Aggregation Switches
24-port Layer 3 PoE+ switch with 2.5 GbE and 10G SFP+ · Ref. : USW-ENTERPRISE-24-POE
Price on request
Core and Aggregation Switches
IP65 high bay dual sense presence sensor HF and PIR · Ref. : HIM30-B-L2
Price on request
Core and Aggregation Switches
28-port GbE L3 aggregation switch with 4 SFP+ uplinks
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details