S9828
High-density 128-port 800G L3 switch for data centers

- Operating Temperature
- 0°C to 40°C
- Max Power Consumption
- 6141W
- Static Power Consumption
- 758W
- Typical Power Consumption
- 1861W
High-density 128-port 800G L3 switch for data centers
H3C S9828-128EP core and aggregation switch with 128 800G ports for data centers and cloud networks, offering 204.8 Tbps switching capacity and lossless RoCEv2 transmission for AI networks.
Overview. The H3C S9828-128EP is a high-density L3 Ethernet switch from the H3C S9828 series, designed for data centers and cloud computing networks. It provides 128 OSFP800 ports and a switching capacity of 204.8 Tbps in a 4U chassis.
Forwarding performance and table capacity — The switch reaches a forwarding performance of 37.56 Bpps and supports up to 850K unicast IPv4 routes and 360k unicast IPv6 routes, with 16K IPv4 ARP entries, 8K MAC addresses and 4K ECMP groups. Memory comprises 64GB of Flash and 16GB of SDRAM, with a 4-core CPU at 2.6GHz.
Ports and interfaces. The 128 OSFP800 ports can be reduced to 400G and split into 2*100G, 2*200G, 2*400G, 4*200G or 8*100G. One RJ45 out-of-band management port is provided.
Lossless transmission and AI networks. The switch supports RDMA and RoCEv2, PFC and ECN, AI ECN, PFC deadlock watchdog, DCB/DCBX/ETS, and docking with CX7/CX8 series intelligent network cards, for AIGC network requirements.
Routing and network virtualization. The switch supports IPv4 routing (static, RIP, OSPF, IS-IS, BGP, VRRP, PBR) and IPv6 routing (RIPng, OSPFv3, IPv6 IS-IS, BGP4+, VRRP, PBR), with L2 and L3 VXLAN gateways for EVPN VXLAN networks.
Reliability and telemetry. STP/RSTP/MSTP, PVST+/RPVST+, ERPS, Monitor-link, BFD and VRRP/VRRPE provide redundancy. Telemetry uses gRPC and ERSPAN, with traffic analysis through Sflow, Netstream and ROCEv2 stream analysis.
Power and environment. The switch takes 4 power modules in 2+2 redundancy, including the 3200W PSR3200-12A-A module, and 8 fan slots in 7+1 redundancy (FAN-80B-1-D). Typical power consumption is 1861W and maximum power consumption is 6141W. It operates from 0°C to 40°C at 5% to 95% humidity, noncondensing.
Automation. The switch is programmable through OpenFlow 1.3, Netconf, Ansible and Python, TCL and RESTful APIs for automated DevOps operations. Configuration and maintenance are available via console, telnet, SSH 2.0, SNMPv1/v2/v3 and ZTP.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for S9828, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| ACL — max number of ingress ACLs | 2K-1 |
| Air flow direction | From front to rear |
| Configuration and maintenance | Console telnet and SSH terminals; SNMPv1/v2/v3; ZTP (Zero Touch Provisioning); System log; File upload and download via FTP/TFTP; BootRom update and remote update; NQA; ping,tracert; NTP; Authentication methods,including AAA,RADIUS and HWTACACS; SSH 2.0; SSL; PKI; Boot ROM access control (password recovery); RMON; configuration rollback |
| CPU | 4 cores, 2.6GHZ |
| Dimensions (H × D × H,) | 1092mm*655mm*391mm ( with package); 175mm*447mm*760mm ( without package) |
| EVPN VxLAN | L2 VxLAN gateway; L3 VxLAN gateway |
| Fan — FAN-80B-1-D | Fan Module (Fan Panel Side Exhaust Airflow) |
| Fan tray slot | 8 (7+1 redundancy) |
| Flash | 64GB |
| Forwarding performance | 37.56 Bpps |
| Forwarding table — BGP peer | 8K |
| Forwarding table — ECMP group | 4K |
| Forwarding table — max ND table size for IPv6 | 16K |
| Forwarding table — max number of ARP entries IPv4 | 16K |
| Forwarding table — max number of MACs per switch | 8K |
| Forwarding table — max number of unicast routes IPv4 | 850K |
| Forwarding table — max number of unicast routes IPv6 | 360k |
| IPv4 routing | static routes and default routes.; RIP(Routing Information Protocol) v1/2; OSPF (Open Shortest Path First) v1/v2; ISIS(Intermediate System to Intermediate system); BGP (Border Gateway Protocol); Routing policy; VRRP; PBR |
| IPv6 routing | static routes and default routes.; RIPng; OSPFv3; IPv6 ISIS; BGP4+; Routing policy; VRRP; PBR |
| Layer 2 | VLAN based on port, protocol, and MAC. |
| Load balance algorithm | path navigation load balancing----Traffic Matrix load balancing and Adjust UDP source port number; LBN/LBN enhanced,Spraylink |
| Lossless network | RDMA and ROCEv2; PFC and ECN,AI ECN, PFC deadlock watchdog; DCB/DCBX/ETS; iNOFv4/ iNOFv6, IPCC,; Supports intelligent network card docking with mainstream CX7/CX8 series. |
| Max Power Consumption | 6141W |
| Model — LS-9828-128EP | H3C S9828-128EP L3 Ethernet Switch Host |
| MPU — LSWM3SUPX1 | H3C S9800 Supervisor Engine Module |
| Operating Humidity | 5% to 95%, noncondensing |
| Operating Temperature | 0°C to 40°C |
| OSFP 800 | 128(Supports port speed reduction to 400G, Supports port splitting: 2*100G, 2*200G, 2*400G, 4*200G, and 8*100G) |
| Out-of-band management port | RJ45*1 |
| Power module slot | 4 (2+2 redundancy) |
| Programmability | Openflow1.3; Netconf,; Ansible; Python/TCL/Restful API to realize DevOps automated operation and maintenance |
| PSU — PSR3200-12A-A | 3200W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Reliability | STP/RSTP/MSTP protocol, PVST+/RPVST+ compatible; STP Root Guard and BPDU Guard; ERPS; Monitor-link; BFD for OSPF/OSPFv3, BGP/BGP4, IS-IS/IS-ISv6, PIM/IPM for IPv6 and Static route; VRRP and VRRPE |
| SDRAM | 16GB |
| Static Power Consumption | 758W |
| Storage Temperature | -40ºC~70ºC |
| Switching Capacity | 204.8 Tbps |
| Telemetry | gRPC; ERSPAN |
| Traffic analysis | Sflow; Netstream; ROCEv2 stream analysis |
| Typical Power Consumption | 1861W |
| Weight(Full loaded) | 41.25Kg (fully configured, including MPU+ fan+power supply, excluding slide rail and accessories); 48.53Kg (fully configured + packaging materials) |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for S9828. For a missing document or a specific revision, our experts send it to you.
H3C S9828-128EP core and aggregation switch with 128 800G ports for data centers and cloud networks, offering 204.8 Tbps switching capacity and lossless RoCEv2 transmission for AI networks.
| Parameter | Value |
|---|---|
| ACL — max number of ingress ACLs | 2K-1 |
| Air flow direction | From front to rear |
| Configuration and maintenance | Console telnet and SSH terminals; SNMPv1/v2/v3; ZTP (Zero Touch Provisioning); System log; File upload and download via FTP/TFTP; BootRom update and remote update; NQA; ping,tracert; NTP; Authentication methods,including AAA,RADIUS and HWTACACS; SSH 2.0; SSL; PKI; Boot ROM access control (password recovery); RMON; configuration rollback |
| CPU | 4 cores, 2.6GHZ |
| Dimensions (H × D × H,) | 1092mm*655mm*391mm ( with package); 175mm*447mm*760mm ( without package) |
| EVPN VxLAN | L2 VxLAN gateway; L3 VxLAN gateway |
| Fan — FAN-80B-1-D | Fan Module (Fan Panel Side Exhaust Airflow) |
| Fan tray slot | 8 (7+1 redundancy) |
| Flash | 64GB |
| Forwarding performance | 37.56 Bpps |
| Forwarding table — BGP peer | 8K |
| Forwarding table — ECMP group | 4K |
| Forwarding table — max ND table size for IPv6 | 16K |
| Forwarding table — max number of ARP entries IPv4 | 16K |
| Forwarding table — max number of MACs per switch | 8K |
| Forwarding table — max number of unicast routes IPv4 | 850K |
| Forwarding table — max number of unicast routes IPv6 | 360k |
| IPv4 routing | static routes and default routes.; RIP(Routing Information Protocol) v1/2; OSPF (Open Shortest Path First) v1/v2; ISIS(Intermediate System to Intermediate system); BGP (Border Gateway Protocol); Routing policy; VRRP; PBR |
| IPv6 routing | static routes and default routes.; RIPng; OSPFv3; IPv6 ISIS; BGP4+; Routing policy; VRRP; PBR |
| Layer 2 | VLAN based on port, protocol, and MAC. |
| Load balance algorithm | path navigation load balancing----Traffic Matrix load balancing and Adjust UDP source port number; LBN/LBN enhanced,Spraylink |
| Lossless network | RDMA and ROCEv2; PFC and ECN,AI ECN, PFC deadlock watchdog; DCB/DCBX/ETS; iNOFv4/ iNOFv6, IPCC,; Supports intelligent network card docking with mainstream CX7/CX8 series. |
| Max Power Consumption | 6141W |
| Model — LS-9828-128EP | H3C S9828-128EP L3 Ethernet Switch Host |
| MPU — LSWM3SUPX1 | H3C S9800 Supervisor Engine Module |
| Operating Humidity | 5% to 95%, noncondensing |
| Operating Temperature | 0°C to 40°C |
| OSFP 800 | 128(Supports port speed reduction to 400G, Supports port splitting: 2*100G, 2*200G, 2*400G, 4*200G, and 8*100G) |
| Out-of-band management port | RJ45*1 |
| Power module slot | 4 (2+2 redundancy) |
| Programmability | Openflow1.3; Netconf,; Ansible; Python/TCL/Restful API to realize DevOps automated operation and maintenance |
| PSU — PSR3200-12A-A | 3200W AC Power Supply Module (Power Panel Side Exhaust Airflow) |
| Reliability | STP/RSTP/MSTP protocol, PVST+/RPVST+ compatible; STP Root Guard and BPDU Guard; ERPS; Monitor-link; BFD for OSPF/OSPFv3, BGP/BGP4, IS-IS/IS-ISv6, PIM/IPM for IPv6 and Static route; VRRP and VRRPE |
| SDRAM | 16GB |
| Static Power Consumption | 758W |
| Storage Temperature | -40ºC~70ºC |
| Switching Capacity | 204.8 Tbps |
| Telemetry | gRPC; ERSPAN |
| Traffic analysis | Sflow; Netstream; ROCEv2 stream analysis |
| Typical Power Consumption | 1861W |
| Weight(Full loaded) | 41.25Kg (fully configured, including MPU+ fan+power supply, excluding slide rail and accessories); 48.53Kg (fully configured + packaging materials) |
Points to check before using S9828 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Max Power Consumption | 6141W |
| Power module slot | 4 (2+2 redundancy) |
| Static Power Consumption | 758W |
| Typical Power Consumption | 1861W |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of S9828 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Model — LS-9828-128EP": H3C S9828-128EP L3 Ethernet Switch Host.
0°C to 40°C (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
High-density 128-port 800G L3 switch for data centers

30 Port SFP+ Layer 3 Managed Industrial Ethernet Switch

Layer 3 10GBASE-X SFP+ + 4-Port 10GBASE-T Managed Ethernet Switch

L3 100/1G SFP with 4 shared 10/100/1000T + 10-Port 1G/2.5G SFP + 4-Port 10G SFP+ Metro Ethernet Switch

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | S9828 |
| Manufacturer | H3C |
Core and Aggregation Switches
Gigabit Managed Layer 3 Switch with 4 SFP Ports · Ref. : DGS-3312SR
Price on request
Core and Aggregation Switches
24-port Layer 3 PoE+ switch with 2.5 GbE and 10G SFP+ · Ref. : USW-ENTERPRISE-24-POE
Price on request
Core and Aggregation Switches
IP65 high bay dual sense presence sensor HF and PIR · Ref. : HIM30-B-L2
Price on request
Core and Aggregation Switches
28-port GbE L3 aggregation switch with 4 SFP+ uplinks
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details