S9850
Core data center switch, modular 100G chassis

- Operating Temperature
- 0°C to 45°C (32°F to 113°F)
- Interface
- 1K
- AC input voltage
- 90v to 264v
- DC Input Voltage
- –40v to –72v
Core data center switch, modular 100G chassis
High-density L3 H3C S9850 switch for data centers and cloud networks, with 100G and 40G ports for aggregation and 25G or 10G access.
Overview. The H3C S9850 is a Layer 3 Ethernet switch from H3C's Data Center series, designed for data center and cloud computing networks. It is available in several chassis models, including the S9850-4C, S9850-32H and S9850-32H-G.
Main characteristics. The switch provides a hardware forwarding capacity of 2024 Mpps, a latency below 1 μs for a 64-byte frame, a forwarding table of 288K entries and a 32 MB buffer. It supports up to 32 QSFP28 100G ports on the S9850-32H and IRF stacking with a convergence time below 50 milliseconds on the S9850-32H-G.
Interfaces and connectivity. The available interface modules cover 40G QSFP+, 100G QSFP28 with or without MACSec, 25G SFP28, 10G SFP+ and 10GBASE-T, along with FC and FCoE cards on the S9850-4C. Two out-of-band management ports are provided, one GE copper port and one GE fiber port. Configuration protocols include SNMPv1/v2/v3, ZTP, NTP, PTP (1588v2) and file transfer over FTP and TFTP.
Power and environment. The models accept AC input from 90 V to 264 V or DC input from -40 V to -72 V, with hot-swappable power modules. Operation is specified from 0 °C to 45 °C, with 5% to 95% humidity, non-condensing. Airflow is configurable from front to rear or rear to front depending on the fan module installed.
Typical uses. This switch suits 100GE or 25GE access and aggregation in data centers, and can operate as a top-of-rack switch in an overlay or integrated network. VxLAN, BGP-EVPN, MPLS VPN, M-LAG and lossless network protocols (PFC, ECN, RDMA and RoCE) address cloud and storage architectures.
Integration. The switch supports OpenFlow 1.3, NETCONF, RESTCONF and Ansible for operations automation, together with LACP, STP, RRPP, ERPS, BFD and VRRP for high availability. It is offered on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for S9850, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| AC input voltage | 90v to 264v |
| ACL | 18K/pipe, total 2 pipes |
| Air flow direction | From front to rear or from rear to front |
| Buffer | 32M |
| Cable — LSWM1QSTK0 | 40G QSFP+ Cable 1m |
| Cable — LSWM1QSTK1 | 40G QSFP+ Cable 3m |
| Cable — LSWM1QSTK2 | 40G QSFP+ Cable 5m |
| Cable — LSWM1QSTK3 | 40G QSFP+ to 4x10G SFP+ Cable 1m |
| Cable — LSWM1QSTK4 | 40G QSFP+ to 4x10G SFP+ Cable 3m |
| Cable — LSWM1QSTK5 | 40G QSFP+ to 4x10G SFP+ Cable 5m |
| Cable — QSFP-100G-4SFP-25G-CAB-1M | 100G QSFP28 to 4x25G SFP28 1m Passive Cable |
| Cable — QSFP-100G-4SFP-25G-CAB-3M | 100G QSFP28 to 4x25G SFP28 3m Passive Cable |
| Cable — QSFP-100G-4SFP-25G-CAB-5M | 100G QSFP28 to 4x25G SFP28 5m Passive Cable |
| Cable — QSFP-100G-D-AOC-10M | 100G QSFP28 to 100G QSFP28 10m Active Optical Cable |
| Cable — QSFP-100G-D-AOC-20M | 100G QSFP28 to 100G QSFP28 20m Active Optical Cable |
| Cable — QSFP-100G-D-AOC-7M | 100G QSFP28 to 100G QSFP28 7m Active Optical Cable |
| Cable — QSFP-100G-D-CAB-1M | 100G QSFP28 to 100G QSFP28 1m Passive Cable |
| Cable — QSFP-100G-D-CAB-3M | 100G QSFP28 to 100G QSFP28 3m Passive Cable |
| Cable — QSFP-100G-D-CAB-5M | 100G QSFP28 to 100G QSFP28 5m Passive Cable |
| Cable — QSFP-40G-D-AOC-10M | 40G QSFP+ to 40G QSFP+ 10m Active Optical Cable |
| Cable — QSFP-40G-D-AOC-20M | 40G QSFP+ to 40G QSFP+ 20m Active Optical Cable |
| Cable — QSFP-40G-D-AOC-7M | 40G QSFP+ to 40G QSFP+ 7m Active Optical Cable |
| Chassis | LS-9850-4C /LS-9850-4C-H1 |
| Chassis — LS-9850-32H-G | H3C S9850-32H-G L3 Ethernet Switch with 16*QSFP28 Ports and 16*QSFP28 Ports or 4*QSFP-DD Ports, Without Power Supplies |
| Chassis — LS-9850-32H-H1 | H3C S9850-32H L3 Ethernet Switch with 32 QSFP28 Ports |
| Chassis — LS-9850-4C-H1 | H3C S9850-4C-H1 L3 Ethernet Switch with 4*Interface Module Slots |
| Configuration and maintenance | Console telnet and SSH terminals; SNMPv1/v2/v3; ZTP; System log; File upload and download via FTP/TFTP; BootRom update and remote update; NQA; ping,tracert; VxLAN ping and VxLAN tracert; NTP; PTP(1588v2); GIR Graceful Insertion and Removal |
| CPU | LS-9850-4C-H1: 4 cores, 2.2 GHz |
| DC Input Voltage | –40v to –72v |
| Device virtualization | IRF; M-LAG(DRNI); S-MLAG |
| Dimensions H*W*D | 88.1 × 440 × 660 mm (3.47 × 17.32 × 25.98 in) |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 24; EN 55024; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386; GB/T 9254; YD/T 993 |
| Fan — LSPM1FANSA-SN | H3C Fan Module (Fan Panel Side Intake Airflow), for LS-9850-32H-G |
| Fan — LSPM1FANSB-SN | H3C Fan Module (Fan Panel Side Exhaust Airflow), for LS-9850-32H-G |
| Fan — LSWM1BFANSC | Fan Module (Fan Panel Side Intake Airflow) |
| Fan — LSWM1BFANSCB | Fan Module (Fan Panel Side Exhaust Airflow) |
| Fan — LSWM1FANSA | Fan Module (SW, 4056, DC, Fan Panel Side Intake Airflow) |
| Fan — LSWM1FANSAB | Fan Module (SW, 4056, DC, Fan Panel Side Exhaust Airflow) |
| FC/FCoE | FC, FC subcard is supported on S9850-4C; FCOE |
| Flash/SDRAM | 8GB/8GB |
| Forwarding | Hardware-based(ASlC)Wire-speed/Line-rate architecture |
| Forwarding Capacity | 2024 Mpps |
| Forwarding table | 288K max |
| IEEE Standard | 802.3x/802.3ad/802.3AH/802.1P/802.1Q/802.1X/802.1D/802.1w/802.1s/802.1AG; 802.1x/802.1Qbb/802.1az/802.1Qaz |
| Interface | 1K |
| IPv4 routing | Static routing and default routing; RIP(Routing Information Protocol) v1/2; OSPF (Open Shortest Path First) v1/v2; ISIS(Intermediate System to Intermediate system); BGP (Border Gateway Protocol); Routing policy; VRRP; PBR |
| IPv6 routing | Static routing and default routing; RIPng; OSPFv3; IPv6 ISIS; BGP4+; Routing policy; VRRP; PBR |
| Latency | < 1μs (64-byte ) |
| Lossless network | PFC and ECN; DCBX; RDMA and ROCE; PFC deadlock watchdog; ECN overlay; ROCE stream analysis |
| MAC Address | Dynamic learning and aging of mac address entries; Dynamic,static and blackhole entries; Mac address limiting on ports |
| Maximum power consumption | With four LSWM18CQ modules: 688 W; With four LSWM18CQMSEC modules: 748 W; With four LSWM116Q modules: 616 W; With four LSWM18QC modules: 496 W; With four LSWM124XG2Q modules: 616 W; With four LSWM124XGT2Q modules: 868 W; With four LSWM124XG2QFC modules: 616 W; With four LSWM124XG2QL modules: 520 W; With four LSWM124TG2H modules: 688 W; With four LSWM116FC modules: 616 W |
| Module — LSWM116Q | H3C 16-Port 40G Ethernet Optical Interface Module(QSFP Plus) |
| Module — LSWM124TG2H | H3C 24-Port 25G Ethernet Optical Interface (SFP28) and 2-Port 100G Ethernet Optical Interface (QSFP28) Module |
| Module — LSWM124XG2Q | 24-Port SFP Plus and 2-Port QSFP Plus Interface Card with MACSec |
| Module — LSWM124XG2QFC | 24 Ports SFP Plus and 2 Ports QSFP Plus Interface Card with FC |
| Module — LSWM124XG2QL | 24-Port SFP Plus and 2-Port QSFP Plus Interface Card |
| Module — LSWM124XGT2Q | 24-Port 10GBASE-T and 2-Port QSFP Plus Interface Card with MACSec |
| Module — LSWM18CQ | H3C 8-Port 100G Ethernet Optical Interface Module(QSFP28) |
| Module — LSWM18CQMSEC | H3C 8-Port 100G MACSEC Ethernet Optical Interface Module(QSFP28) |
| Module — LSWM18QC | 8-Port QSFP Plus Interface Card |
| MPLS/VPLS | Support L3 MPLS VPN; Support L2 VPN: VLL (Martini, Kompella); Support VPLS, VLL; Support hierarchical VPLS and QinQ+VPLS access; Support P/PE function; Support LDP protocol; Support MCE; Support MPLS OAM |
| MTBF(years) | 45.8 |
| Multicast | IGMP snooping; MLD snooping; IPv4 and IPv6 multicast VLAN; IPv4 and IPv6 PIM snooping; IGMP and MLD; PIM and IPv6 PIM; MSDP; Multicast VPN |
| Network virtualization | BGP-EVPN; VxLAN; EVPN ES |
| Operating Humidity | 5% to 95%, noncondensing |
| Operating Temperature | 0°C to 45°C (32°F to 113°F) |
| Out-of-band management port | One GE copper port and one GE fiber port |
| Performance | 1M |
| Power — LSVM1AC650 | 650W AC Power Supply Module(Air Inlets in Panel) |
| Power — LSVM1DC650 | 650W DC Power Supply Module(Air Inlets in Panel) |
| Power — PSR450-12A | 450W AC Power Supply Module (Power Panel Side Intake Airflow), for LS-9850-32H-G |
| Power — PSR450-12A1 | 450W AC Power Supply Module (Power Panel Side Exhaust Airflow), for LS-9850-32H-G |
| Power — PSR450-12D | 450W DC Power Supply Module (Power Panel Side Exhaust Airflow), for LS-9850-32H-G |
| Programmability | Openflow1.3; Netconf; Ansible; Python//TCL/Restful/Restconf API to realize DevOps automated operation and maintenance; Openflow1.3 |
| QSFP28/QSFP+ | / |
| Reliability | LACP; STP/RSTP/MSTP protocol, PVST/PVST+/RPVST+compatible; STP Root Guard and BPDU Guard; RRPP and ERPS; Ethernet OAM; Smartlink; DLDP; BFD for OSPF/OSPFv3, BGP/BGP4, IS-IS/IS-ISv6, PIM/IPM for IPv6 and Static route; VRRP and VRRPE; LACP |
| Safety | UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1, EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| SDN | H3C SeerEngine-DC |
| Security and management | Authentication methods, including AAA,RADIUS and HWTACACS; Secure boot |
| Static table | 1K |
| Switching Capacity | 6.4 Tbps |
| TAP; (Only for S9850-32H-G) | Support N:M replication based on port and traffic, with M or N ≥ 48.; Support GRE tunnel encapsulation stripping, support same source and same host, support packet truncation.; Support source port identification.; Support adding timestamps and Ethernet headers.; Identify specified packets, modify MAC address or IP address, and then copy and forward. |
| Telemetry | gRPC; ERSPAN; Mirror on drop; Telemetry Stream; INT; iNQA; Packet trace, Packet capture |
| Traffic analysis | Sflow; Netstream |
| Transceiver — SFP-FE-LH40-SM1310 | 100BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| Transceiver — SFP-FE-LX-SM1310-A | 100BASE-LX SFP Transceiver, Single Mode (1310nm, 15km, LC) |
| Transceiver — SFP-FE-SX-MM1310-A | 100BASE-FX SFP Transceiver, Multi-Mode (1310nm, 2km, LC) |
| Transceiver — SFP-GE-LH40-SM1310 | 1000BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| Transceiver — SFP-GE-LH40-SM1550 | 1000BASE-LH40 SFP Transceiver, Single Mode (1550nm, 40km, LC) |
| Transceiver — SFP-GE-LH80-SM1550 | 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC) |
| Transceiver — SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| Transceiver — SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| Transceiver — SFP-GE-T | SFP GE Copper Interface Transceiver Module (100m,RJ45) |
| Typical Power Consumption | With four LSWM18CQ modules: 355 W; With four LSWM18CQMSEC modules: 443 W; With four LSWM116Q modules: 311 W; With four LSWM18QC modules: 251 W; With four LSWM124XG2Q modules: 363 W; With four LSWM124XGT2Q modules: 487 W; With four LSWM124XG2QFC modules: 363 W; With four LSWM124XG2QL modules: 275 W; With four LSWM124TG2H modules: 355 W; With four LSWM116FC modules: 311 W |
| Typical thermal consumption | With four LSWM18CQ modules: 1211 BTU/hr; With four LSWM18CQMSEC modules: 1512 BTU/hr; With four LSWM116Q modules: 1061 BTU/hr; With four LSWM18QC modules: 856 BTU/hr; With four LSWM124XG2Q modules: 1239 BTU/hr; With four LSWM124XGT2Q modules: 1662 BTU/hr; With four LSWM124XG2QFC modules: 1239 BTU/hr; With four LSWM124XG2QL modules: 938 BTU/hr; With four LSWM124TG2H modules: 1211 BTU/hr; With four LSWM116FC modules: 1061 BTU/hr |
| VLAN | Port-based VLANs; Mac-based VLAN,Subnet-based VLAN and Protocol VLAN; VLAN mapping; QinQ; MVRP(Multiple VLAN Registration Protocol); Super VLAN; PVLAN |
| VXLAN | L2 VxLAN gateway; L3 VxLAN gateway; Distributed VxLAN gateway; Centralized VxLAN gateway; EVPN VxLAN; manual configured VxLAN; IPv4 VxLAN tunnel; IPv6 VxLAN tunnel; QinQ VxLAN access |
| Weight(Full loaded) | ≤ 27 kg (59.53 lb) |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for S9850. For a missing document or a specific revision, our experts send it to you.
High-density L3 H3C S9850 switch for data centers and cloud networks, with 100G and 40G ports for aggregation and 25G or 10G access.
| Parameter | Value |
|---|---|
| AC input voltage | 90v to 264v |
| ACL | 18K/pipe, total 2 pipes |
| Air flow direction | From front to rear or from rear to front |
| Buffer | 32M |
| Cable — LSWM1QSTK0 | 40G QSFP+ Cable 1m |
| Cable — LSWM1QSTK1 | 40G QSFP+ Cable 3m |
| Cable — LSWM1QSTK2 | 40G QSFP+ Cable 5m |
| Cable — LSWM1QSTK3 | 40G QSFP+ to 4x10G SFP+ Cable 1m |
| Cable — LSWM1QSTK4 | 40G QSFP+ to 4x10G SFP+ Cable 3m |
| Cable — LSWM1QSTK5 | 40G QSFP+ to 4x10G SFP+ Cable 5m |
| Cable — QSFP-100G-4SFP-25G-CAB-1M | 100G QSFP28 to 4x25G SFP28 1m Passive Cable |
| Cable — QSFP-100G-4SFP-25G-CAB-3M | 100G QSFP28 to 4x25G SFP28 3m Passive Cable |
| Cable — QSFP-100G-4SFP-25G-CAB-5M | 100G QSFP28 to 4x25G SFP28 5m Passive Cable |
| Cable — QSFP-100G-D-AOC-10M | 100G QSFP28 to 100G QSFP28 10m Active Optical Cable |
| Cable — QSFP-100G-D-AOC-20M | 100G QSFP28 to 100G QSFP28 20m Active Optical Cable |
| Cable — QSFP-100G-D-AOC-7M | 100G QSFP28 to 100G QSFP28 7m Active Optical Cable |
| Cable — QSFP-100G-D-CAB-1M | 100G QSFP28 to 100G QSFP28 1m Passive Cable |
| Cable — QSFP-100G-D-CAB-3M | 100G QSFP28 to 100G QSFP28 3m Passive Cable |
| Cable — QSFP-100G-D-CAB-5M | 100G QSFP28 to 100G QSFP28 5m Passive Cable |
| Cable — QSFP-40G-D-AOC-10M | 40G QSFP+ to 40G QSFP+ 10m Active Optical Cable |
| Cable — QSFP-40G-D-AOC-20M | 40G QSFP+ to 40G QSFP+ 20m Active Optical Cable |
| Cable — QSFP-40G-D-AOC-7M | 40G QSFP+ to 40G QSFP+ 7m Active Optical Cable |
| Chassis | LS-9850-4C /LS-9850-4C-H1 |
| Chassis — LS-9850-32H-G | H3C S9850-32H-G L3 Ethernet Switch with 16*QSFP28 Ports and 16*QSFP28 Ports or 4*QSFP-DD Ports, Without Power Supplies |
| Chassis — LS-9850-32H-H1 | H3C S9850-32H L3 Ethernet Switch with 32 QSFP28 Ports |
| Chassis — LS-9850-4C-H1 | H3C S9850-4C-H1 L3 Ethernet Switch with 4*Interface Module Slots |
| Configuration and maintenance | Console telnet and SSH terminals; SNMPv1/v2/v3; ZTP; System log; File upload and download via FTP/TFTP; BootRom update and remote update; NQA; ping,tracert; VxLAN ping and VxLAN tracert; NTP; PTP(1588v2); GIR Graceful Insertion and Removal |
| CPU | LS-9850-4C-H1: 4 cores, 2.2 GHz |
| DC Input Voltage | –40v to –72v |
| Device virtualization | IRF; M-LAG(DRNI); S-MLAG |
| Dimensions H*W*D | 88.1 × 440 × 660 mm (3.47 × 17.32 × 25.98 in) |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 24; EN 55024; EN 61000-3-2; EN 61000-3-3; ETSI EN 300 386; GB/T 9254; YD/T 993 |
| Fan — LSPM1FANSA-SN | H3C Fan Module (Fan Panel Side Intake Airflow), for LS-9850-32H-G |
| Fan — LSPM1FANSB-SN | H3C Fan Module (Fan Panel Side Exhaust Airflow), for LS-9850-32H-G |
| Fan — LSWM1BFANSC | Fan Module (Fan Panel Side Intake Airflow) |
| Fan — LSWM1BFANSCB | Fan Module (Fan Panel Side Exhaust Airflow) |
| Fan — LSWM1FANSA | Fan Module (SW, 4056, DC, Fan Panel Side Intake Airflow) |
| Fan — LSWM1FANSAB | Fan Module (SW, 4056, DC, Fan Panel Side Exhaust Airflow) |
| FC/FCoE | FC, FC subcard is supported on S9850-4C; FCOE |
| Flash/SDRAM | 8GB/8GB |
| Forwarding | Hardware-based(ASlC)Wire-speed/Line-rate architecture |
| Forwarding Capacity | 2024 Mpps |
| Forwarding table | 288K max |
| IEEE Standard | 802.3x/802.3ad/802.3AH/802.1P/802.1Q/802.1X/802.1D/802.1w/802.1s/802.1AG; 802.1x/802.1Qbb/802.1az/802.1Qaz |
| Interface | 1K |
| IPv4 routing | Static routing and default routing; RIP(Routing Information Protocol) v1/2; OSPF (Open Shortest Path First) v1/v2; ISIS(Intermediate System to Intermediate system); BGP (Border Gateway Protocol); Routing policy; VRRP; PBR |
| IPv6 routing | Static routing and default routing; RIPng; OSPFv3; IPv6 ISIS; BGP4+; Routing policy; VRRP; PBR |
| Latency | < 1μs (64-byte ) |
| Lossless network | PFC and ECN; DCBX; RDMA and ROCE; PFC deadlock watchdog; ECN overlay; ROCE stream analysis |
| MAC Address | Dynamic learning and aging of mac address entries; Dynamic,static and blackhole entries; Mac address limiting on ports |
| Maximum power consumption | With four LSWM18CQ modules: 688 W; With four LSWM18CQMSEC modules: 748 W; With four LSWM116Q modules: 616 W; With four LSWM18QC modules: 496 W; With four LSWM124XG2Q modules: 616 W; With four LSWM124XGT2Q modules: 868 W; With four LSWM124XG2QFC modules: 616 W; With four LSWM124XG2QL modules: 520 W; With four LSWM124TG2H modules: 688 W; With four LSWM116FC modules: 616 W |
| Module — LSWM116Q | H3C 16-Port 40G Ethernet Optical Interface Module(QSFP Plus) |
| Module — LSWM124TG2H | H3C 24-Port 25G Ethernet Optical Interface (SFP28) and 2-Port 100G Ethernet Optical Interface (QSFP28) Module |
| Module — LSWM124XG2Q | 24-Port SFP Plus and 2-Port QSFP Plus Interface Card with MACSec |
| Module — LSWM124XG2QFC | 24 Ports SFP Plus and 2 Ports QSFP Plus Interface Card with FC |
| Module — LSWM124XG2QL | 24-Port SFP Plus and 2-Port QSFP Plus Interface Card |
| Module — LSWM124XGT2Q | 24-Port 10GBASE-T and 2-Port QSFP Plus Interface Card with MACSec |
| Module — LSWM18CQ | H3C 8-Port 100G Ethernet Optical Interface Module(QSFP28) |
| Module — LSWM18CQMSEC | H3C 8-Port 100G MACSEC Ethernet Optical Interface Module(QSFP28) |
| Module — LSWM18QC | 8-Port QSFP Plus Interface Card |
| MPLS/VPLS | Support L3 MPLS VPN; Support L2 VPN: VLL (Martini, Kompella); Support VPLS, VLL; Support hierarchical VPLS and QinQ+VPLS access; Support P/PE function; Support LDP protocol; Support MCE; Support MPLS OAM |
| MTBF(years) | 45.8 |
| Multicast | IGMP snooping; MLD snooping; IPv4 and IPv6 multicast VLAN; IPv4 and IPv6 PIM snooping; IGMP and MLD; PIM and IPv6 PIM; MSDP; Multicast VPN |
| Network virtualization | BGP-EVPN; VxLAN; EVPN ES |
| Operating Humidity | 5% to 95%, noncondensing |
| Operating Temperature | 0°C to 45°C (32°F to 113°F) |
| Out-of-band management port | One GE copper port and one GE fiber port |
| Performance | 1M |
| Power — LSVM1AC650 | 650W AC Power Supply Module(Air Inlets in Panel) |
| Power — LSVM1DC650 | 650W DC Power Supply Module(Air Inlets in Panel) |
| Power — PSR450-12A | 450W AC Power Supply Module (Power Panel Side Intake Airflow), for LS-9850-32H-G |
| Power — PSR450-12A1 | 450W AC Power Supply Module (Power Panel Side Exhaust Airflow), for LS-9850-32H-G |
| Power — PSR450-12D | 450W DC Power Supply Module (Power Panel Side Exhaust Airflow), for LS-9850-32H-G |
| Programmability | Openflow1.3; Netconf; Ansible; Python//TCL/Restful/Restconf API to realize DevOps automated operation and maintenance; Openflow1.3 |
| QSFP28/QSFP+ | / |
| Reliability | LACP; STP/RSTP/MSTP protocol, PVST/PVST+/RPVST+compatible; STP Root Guard and BPDU Guard; RRPP and ERPS; Ethernet OAM; Smartlink; DLDP; BFD for OSPF/OSPFv3, BGP/BGP4, IS-IS/IS-ISv6, PIM/IPM for IPv6 and Static route; VRRP and VRRPE; LACP |
| Safety | UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1, EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| SDN | H3C SeerEngine-DC |
| Security and management | Authentication methods, including AAA,RADIUS and HWTACACS; Secure boot |
| Static table | 1K |
| Switching Capacity | 6.4 Tbps |
| TAP; (Only for S9850-32H-G) | Support N:M replication based on port and traffic, with M or N ≥ 48.; Support GRE tunnel encapsulation stripping, support same source and same host, support packet truncation.; Support source port identification.; Support adding timestamps and Ethernet headers.; Identify specified packets, modify MAC address or IP address, and then copy and forward. |
| Telemetry | gRPC; ERSPAN; Mirror on drop; Telemetry Stream; INT; iNQA; Packet trace, Packet capture |
| Traffic analysis | Sflow; Netstream |
| Transceiver — SFP-FE-LH40-SM1310 | 100BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| Transceiver — SFP-FE-LX-SM1310-A | 100BASE-LX SFP Transceiver, Single Mode (1310nm, 15km, LC) |
| Transceiver — SFP-FE-SX-MM1310-A | 100BASE-FX SFP Transceiver, Multi-Mode (1310nm, 2km, LC) |
| Transceiver — SFP-GE-LH40-SM1310 | 1000BASE-LH40 SFP Transceiver, Single Mode (1310nm, 40km, LC) |
| Transceiver — SFP-GE-LH40-SM1550 | 1000BASE-LH40 SFP Transceiver, Single Mode (1550nm, 40km, LC) |
| Transceiver — SFP-GE-LH80-SM1550 | 1000BASE-LH80 SFP Transceiver, Single Mode (1550nm, 80km, LC) |
| Transceiver — SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| Transceiver — SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| Transceiver — SFP-GE-T | SFP GE Copper Interface Transceiver Module (100m,RJ45) |
| Typical Power Consumption | With four LSWM18CQ modules: 355 W; With four LSWM18CQMSEC modules: 443 W; With four LSWM116Q modules: 311 W; With four LSWM18QC modules: 251 W; With four LSWM124XG2Q modules: 363 W; With four LSWM124XGT2Q modules: 487 W; With four LSWM124XG2QFC modules: 363 W; With four LSWM124XG2QL modules: 275 W; With four LSWM124TG2H modules: 355 W; With four LSWM116FC modules: 311 W |
| Typical thermal consumption | With four LSWM18CQ modules: 1211 BTU/hr; With four LSWM18CQMSEC modules: 1512 BTU/hr; With four LSWM116Q modules: 1061 BTU/hr; With four LSWM18QC modules: 856 BTU/hr; With four LSWM124XG2Q modules: 1239 BTU/hr; With four LSWM124XGT2Q modules: 1662 BTU/hr; With four LSWM124XG2QFC modules: 1239 BTU/hr; With four LSWM124XG2QL modules: 938 BTU/hr; With four LSWM124TG2H modules: 1211 BTU/hr; With four LSWM116FC modules: 1061 BTU/hr |
| VLAN | Port-based VLANs; Mac-based VLAN,Subnet-based VLAN and Protocol VLAN; VLAN mapping; QinQ; MVRP(Multiple VLAN Registration Protocol); Super VLAN; PVLAN |
| VXLAN | L2 VxLAN gateway; L3 VxLAN gateway; Distributed VxLAN gateway; Centralized VxLAN gateway; EVPN VxLAN; manual configured VxLAN; IPv4 VxLAN tunnel; IPv6 VxLAN tunnel; QinQ VxLAN access |
| Weight(Full loaded) | ≤ 27 kg (59.53 lb) |
Points to check before using S9850 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| AC input voltage | 90v to 264v |
| DC Input Voltage | –40v to –72v |
| Maximum power consumption | With four LSWM18CQ modules: 688 W; With four LSWM18CQMSEC modules: 748 W; With four LSWM116Q modules: 616 W; With four LSWM18QC modules: 496 W; With four LSWM124XG2Q modules: 616 W; With four LSWM124XGT2Q modules: 868 W; With four LSWM124XG2QFC modules: 616 W; With four LSWM124XG2QL modules: 520 W; With four LSWM124TG2H modules: 688 W; With four LSWM116FC modules: 616 W |
| Power — LSVM1AC650 | 650W AC Power Supply Module(Air Inlets in Panel) |
| Power — LSVM1DC650 | 650W DC Power Supply Module(Air Inlets in Panel) |
| Power — PSR450-12A | 450W AC Power Supply Module (Power Panel Side Intake Airflow), for LS-9850-32H-G |
| Power — PSR450-12A1 | 450W AC Power Supply Module (Power Panel Side Exhaust Airflow), for LS-9850-32H-G |
| Power — PSR450-12D | 450W DC Power Supply Module (Power Panel Side Exhaust Airflow), for LS-9850-32H-G |
| Typical Power Consumption | With four LSWM18CQ modules: 355 W; With four LSWM18CQMSEC modules: 443 W; With four LSWM116Q modules: 311 W; With four LSWM18QC modules: 251 W; With four LSWM124XG2Q modules: 363 W; With four LSWM124XGT2Q modules: 487 W; With four LSWM124XG2QFC modules: 363 W; With four LSWM124XG2QL modules: 275 W; With four LSWM124TG2H modules: 355 W; With four LSWM116FC modules: 311 W |
| Typical thermal consumption | With four LSWM18CQ modules: 1211 BTU/hr; With four LSWM18CQMSEC modules: 1512 BTU/hr; With four LSWM116Q modules: 1061 BTU/hr; With four LSWM18QC modules: 856 BTU/hr; With four LSWM124XG2Q modules: 1239 BTU/hr; With four LSWM124XGT2Q modules: 1662 BTU/hr; With four LSWM124XG2QFC modules: 1239 BTU/hr; With four LSWM124XG2QL modules: 938 BTU/hr; With four LSWM124TG2H modules: 1211 BTU/hr; With four LSWM116FC modules: 1061 BTU/hr |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of S9850 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Safety": UL 60950-1; CAN/CSA C22.2 No 60950-1; IEC 60950-1, EN 60950-1; AS/NZS 60950-1; FDA 21 CFR Subchapter J; GB 4943.1.
Yes — recorded under "Chassis — LS-9850-32H-G": H3C S9850-32H-G L3 Ethernet Switch with 16*QSFP28 Ports and 16*QSFP28 Ports or 4*QSFP-DD Ports, Without Power Supplies.
0°C to 45°C (32°F to 113°F) (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Core data center switch, modular 100G chassis

30 Port SFP+ Layer 3 Managed Industrial Ethernet Switch

Layer 3 10GBASE-X SFP+ + 4-Port 10GBASE-T Managed Ethernet Switch

L3 100/1G SFP with 4 shared 10/100/1000T + 10-Port 1G/2.5G SFP + 4-Port 10G SFP+ Metro Ethernet Switch

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | S9850 |
| Manufacturer | H3C |
Core and Aggregation Switches
Gigabit Managed Layer 3 Switch with 4 SFP Ports · Ref. : DGS-3312SR
Price on request
Core and Aggregation Switches
24-port Layer 3 PoE+ switch with 2.5 GbE and 10G SFP+ · Ref. : USW-ENTERPRISE-24-POE
Price on request
Core and Aggregation Switches
IP65 high bay dual sense presence sensor HF and PIR · Ref. : HIM30-B-L2
Price on request
Core and Aggregation Switches
28-port GbE L3 aggregation switch with 4 SFP+ uplinks
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details