US500
Layer 3 Gigabit managed access Ethernet switch

- Networking Interface
- 24*10/100/1000TX+ 4*SFP+
- VLAN interface
- Both IPv4 and IPv6 supported
- Input Voltage
- AC: 90-264V, 47-63Hz.
- Total Power Consumption
- MIN:; AC: 16W; MAX:; AC: 23W
Layer 3 Gigabit managed access Ethernet switch
H3C US500 managed Ethernet switch for Gigabit access and 10G uplinks, with Layer 3 routing, IRF2 stacking and advanced security functions.
Overview. The H3C US500 Ethernet switch is a new generation managed switch designed for networks that require high performance, high port density and easy installation. It provides 10/100/1000Base-T adaptive Ethernet ports or SFP/SFP+ optical ports depending on the model.
Main characteristics. Wire-speed/line-rate architecture, switching capacity of 128Gbps and forwarding capacity of 95.232Mpps. The MAC address table holds 16K entries and the static MAC table 1K entries. It supports 4K VLANs, Jumbo Frame, LACP link aggregation, static routing, RIPv1/v2 and RIPng, and OSPFv1/v2 and OSPFv3.
Interfaces and connectivity. Models with 24 or 48 10/100/1000Base-T ports and 4 SFP or SFP+ 1G/10G ports depending on the version. A console port provides local management. The range also includes PoE+ variants with 802.3af and 802.3at power, and an 8-port 10/100/1000Base-T combo model with 24 ports 100/1000Base-X.
Power and environment. Alternating current input from 90 to 264V, 47 to 63Hz. Consumption of 16W minimum and 23W maximum in AC. Operating temperature from -5 °C to 50 °C, storage from -40 °C to 70 °C, relative humidity from 5% to 95% non-condensing. Dimensions 440×160×43.6 mm, weight up to 2.4 kg, fanless design.
Typical uses. Gigabit access for workstations in enterprise networks, end-user access in metropolitan or industrial networks, and uplinks to core switches over Gigabit or 10G fiber or link aggregation.
Integration and management. Stacking of up to 4 units through IRF2 with distributed device management and distributed link aggregation. Management through CLI, Telnet, SNMPv1/v2c/v3, Web interface and Restful, with Zero Touch Provisioning. Security includes 802.1X, RADIUS, SSH2.0, HTTPs, port security and IP Source Guard.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for US500, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| ACL | Packet filtering at Layer 2 through layer 4 Traffic classification based on source MAC addresses, destination MAC addresses, source IPv4/IPv6 addresses,; Time range-based ACL; VLAN-based ACL; Bidirectional ACL |
| ARP | ARP Detection; ARP speed limit |
| Broadcast/Multicast/Unicast storm suppression | Storm suppression based on port bandwidth percentage; Storm suppression based on PPS; Storm suppression based on BPS; Broadcast traffic/Multicast traffic/Unknown unicast traffic suppression |
| DHCP | DHCP Client; DHCP Snooping; DHCP Snooping option82; DHCP Relay; DHCP Server; DHCP auto-config |
| Dimensions (W/D/H) | 440×160×43.6 mm |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 35; EN 55035; EN 61000-3-2; EN 61000-3-3; GB/T 9254.1 |
| Fan number | Fan-less |
| Flash/SDRAM | 256MB/512MB |
| Forwarding | Wire-speed/Line-rate architecture |
| Forwarding Capacity | 95.232Mpps |
| IEEE | 802.1x Port based network access control protocol |
| IETF | RFC 768 User Datagram Protocol (UDP) |
| Input Voltage | AC: 90-264V, 47-63Hz. |
| IP Routing | Static routing; RIPv1/v2 and RIPng; OSPFv1/v2 and OSPFv3 |
| IPv4 ACL entries | 1K |
| IRF2 | Distributed device management, distributed link aggregation, and distributed resilient routing; Stacking through standard Ethernet interfaces; Local device stacking and remote device stacking |
| ITU | ITU-T Y.1731 |
| Layer 2 Ring Network Protocol | STP/RSTP/MSTP/PVST/PVST+; STP Root Protection; Smart Link; RRPP; G.8032 ERPS (Ethernet Ring Protection Switching) |
| LSTM1STK | SFP+ Cable 5m |
| LSWM1STK | SFP+ Cable 0.65m |
| LSWM2STK | SFP+ Cable 1.2m |
| LSWM3STK | SFP+ Cable 3m |
| MAC address entries | 16K |
| MAC Address Table | Static MAC address; Blackhole MAC address; Setting the maximum number of port MAC addresses to be learned |
| Management and maintenance | Loading and upgrading through XModem/FTP/TFTP; Zero Touch Provisioning; Configuration through CLI, Telnet, and console port; SNMPv1/v2c/v3 and Web-based NMS; Restful; Remote monitoring (RMON ) alarm, event, and history recording; IMC NMS; System log, alarming based on severities, and output of debugging information; NTP; Ping, Tracert; NQA; Virtual cable test (VCT); Device link detection protocol (DLDP); Loopback-detection |
| Management port | 1 console port |
| Maximum stacking num | 4 (only with XF) |
| Mirroring | Port mirroring; Traffic mirroring; RSPAN |
| MTBF(year) | 206.659 |
| Multicast | IGMP Snooping V2/V3; PIM Snooping; MLD Snooping; Multicast VLAN; Multicast VLAN+ |
| Networking Interface | 24*10/100/1000TX+ 4*SFP+ |
| Operating Temperature | -5℃ ~ 50℃(normal operating temperature); -5℃ ~ 45℃(When using transceiver modules with maximum transmission distance < 80km); -5℃ ~ 40℃(When using transceiver modules with maximum transmission distance ≥ 80km) |
| Organization | Standards And Protocols |
| Port Aggregation | GE/10GE port aggregation; Dynamic aggregation; Static aggregation; Cross-device aggregation |
| Port Surge | 6KV |
| Product ID | Product Description |
| QoS | Port rate limit (receiving and transmitting); Packet redirection; Committed access rate (CAR); Eight output queues on each port; Flexible queue scheduling algorithms based on ports and queues, including SP, WRR and SP+WRR; 802.1p DSCP remarking |
| Relative humidity (non-condensing) | 5% RH to 95% RH, non-condensing |
| Safety | UL 62368-1; CAN/CSA C22.2 No 62368-1; IEC 62368-1; EN 62368-1; AS/NZS 62368-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| Security | Hierarchical user management and password protection; AAA authentication support; RADIUS authentication; HWTACACS; SSH2.0; Port isolation; 802.1X authentication, centralized MAC authentication; Port security; IP Source Guard; HTTPs; EAD |
| SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| SFP-GE-T | SFP GE Copper Interface Transceiver Module (100m,RJ45) |
| SFP-XG-LX-SM1310 | SFP+ Module(1310nm,10km,LC) |
| SFP-XG-SX-MM850-E | SFP+ Module(850nm,300m,LC) |
| Static Mac address | 1K |
| Storage Temperature | -40℃ ~ 70℃ |
| Switching Capacity | 128Gbps |
| Total Power Consumption | MIN:; AC: 16W; MAX:; AC: 23W |
| Traffic Control | 802.3x traffic control and half-duplex backpressure |
| Traffic statistic | Sflow |
| US500-24G4F | H3C US500-24G4F Ethernet Switch with 24*10/100/1000BASE-T Ports and 4*1000BASE-X SFP Ports,(AC) |
| US500-24G4XF | H3C US500-24G4XF Ethernet Switch with 24*10/100/1000BASE-T Ports and 4*1G/10G BASE-X SFP Plus Ports,(AC) |
| US500-24G4XF-HP | H3C US500-24G4XF-HP Ethernet Switch with 24*10/100/1000BASE-T PoE+ Ports and 4*1G/10G BASE-X SFP+ Ports,(AC) |
| US500-24G4XF-HP — 375W | 15.4W (802.3af): 24; 30W (802.3at): 12 |
| US500-48G4F | H3C US500-48G4F Ethernet Switch with 48*10/100/1000BASE-T Ports and 4*1000BASE-X SFP Ports,(AC) |
| US500-48G4XF | H3C US500-48G4XF Ethernet Switch with 48*10/100/1000BASE-T Ports and 4*1G/10G BASE-X SFP Plus Ports,(AC) |
| US500-48G4XF-HP | H3C US500-48G4XF-HP Ethernet Switch with 48*10/100/1000BASE-T PoE+ Ports and 4*1G/10G BASE-X SFP+ Ports,(AC) |
| US500-48G4XF-HP — 375W | 15.4W (802.3af): 24; 30W (802.3at): 12 |
| US500-8G24F4XF | H3C US500-8G24F4XF-S Ethernet Switch with 24*100/1000Base-X Ports and 8*10/100/1000Base-T Combo Ports and 4*1G/10GBase-X SFP Plus Ports, Without Power Supplies |
| VLAN | Port-based VLAN; MAC-based VLAN; Protocol-based VLAN; QinQ and selective QinQ; VLAN mapping; Voice VLAN; MVRP |
| VLAN interface | Both IPv4 and IPv6 supported |
| Weight | ≤ 2.4 kg |
No specification matches.
Last verification : 2026-11-06
Official documents and the technical data recorded for US500. For a missing document or a specific revision, our experts send it to you.
H3C US500 managed Ethernet switch for Gigabit access and 10G uplinks, with Layer 3 routing, IRF2 stacking and advanced security functions.
| Parameter | Value |
|---|---|
| ACL | Packet filtering at Layer 2 through layer 4 Traffic classification based on source MAC addresses, destination MAC addresses, source IPv4/IPv6 addresses,; Time range-based ACL; VLAN-based ACL; Bidirectional ACL |
| ARP | ARP Detection; ARP speed limit |
| Broadcast/Multicast/Unicast storm suppression | Storm suppression based on port bandwidth percentage; Storm suppression based on PPS; Storm suppression based on BPS; Broadcast traffic/Multicast traffic/Unknown unicast traffic suppression |
| DHCP | DHCP Client; DHCP Snooping; DHCP Snooping option82; DHCP Relay; DHCP Server; DHCP auto-config |
| Dimensions (W/D/H) | 440×160×43.6 mm |
| EMC | FCC Part 15 Subpart B CLASS A; ICES-003 CLASS A; VCCI CLASS A; CISPR 32 CLASS A; EN 55032 CLASS A; AS/NZS CISPR32 CLASS A; CISPR 35; EN 55035; EN 61000-3-2; EN 61000-3-3; GB/T 9254.1 |
| Fan number | Fan-less |
| Flash/SDRAM | 256MB/512MB |
| Forwarding | Wire-speed/Line-rate architecture |
| Forwarding Capacity | 95.232Mpps |
| IEEE | 802.1x Port based network access control protocol |
| IETF | RFC 768 User Datagram Protocol (UDP) |
| Input Voltage | AC: 90-264V, 47-63Hz. |
| IP Routing | Static routing; RIPv1/v2 and RIPng; OSPFv1/v2 and OSPFv3 |
| IPv4 ACL entries | 1K |
| IRF2 | Distributed device management, distributed link aggregation, and distributed resilient routing; Stacking through standard Ethernet interfaces; Local device stacking and remote device stacking |
| ITU | ITU-T Y.1731 |
| Layer 2 Ring Network Protocol | STP/RSTP/MSTP/PVST/PVST+; STP Root Protection; Smart Link; RRPP; G.8032 ERPS (Ethernet Ring Protection Switching) |
| LSTM1STK | SFP+ Cable 5m |
| LSWM1STK | SFP+ Cable 0.65m |
| LSWM2STK | SFP+ Cable 1.2m |
| LSWM3STK | SFP+ Cable 3m |
| MAC address entries | 16K |
| MAC Address Table | Static MAC address; Blackhole MAC address; Setting the maximum number of port MAC addresses to be learned |
| Management and maintenance | Loading and upgrading through XModem/FTP/TFTP; Zero Touch Provisioning; Configuration through CLI, Telnet, and console port; SNMPv1/v2c/v3 and Web-based NMS; Restful; Remote monitoring (RMON ) alarm, event, and history recording; IMC NMS; System log, alarming based on severities, and output of debugging information; NTP; Ping, Tracert; NQA; Virtual cable test (VCT); Device link detection protocol (DLDP); Loopback-detection |
| Management port | 1 console port |
| Maximum stacking num | 4 (only with XF) |
| Mirroring | Port mirroring; Traffic mirroring; RSPAN |
| MTBF(year) | 206.659 |
| Multicast | IGMP Snooping V2/V3; PIM Snooping; MLD Snooping; Multicast VLAN; Multicast VLAN+ |
| Networking Interface | 24*10/100/1000TX+ 4*SFP+ |
| Operating Temperature | -5℃ ~ 50℃(normal operating temperature); -5℃ ~ 45℃(When using transceiver modules with maximum transmission distance < 80km); -5℃ ~ 40℃(When using transceiver modules with maximum transmission distance ≥ 80km) |
| Organization | Standards And Protocols |
| Port Aggregation | GE/10GE port aggregation; Dynamic aggregation; Static aggregation; Cross-device aggregation |
| Port Surge | 6KV |
| Product ID | Product Description |
| QoS | Port rate limit (receiving and transmitting); Packet redirection; Committed access rate (CAR); Eight output queues on each port; Flexible queue scheduling algorithms based on ports and queues, including SP, WRR and SP+WRR; 802.1p DSCP remarking |
| Relative humidity (non-condensing) | 5% RH to 95% RH, non-condensing |
| Safety | UL 62368-1; CAN/CSA C22.2 No 62368-1; IEC 62368-1; EN 62368-1; AS/NZS 62368-1; FDA 21 CFR Subchapter J; GB 4943.1 |
| Security | Hierarchical user management and password protection; AAA authentication support; RADIUS authentication; HWTACACS; SSH2.0; Port isolation; 802.1X authentication, centralized MAC authentication; Port security; IP Source Guard; HTTPs; EAD |
| SFP-GE-LX-SM1310-A | 1000BASE-LX SFP Transceiver, Single Mode (1310nm, 10km, LC) |
| SFP-GE-SX-MM850-A | 1000BASE-SX SFP Transceiver, Multi-Mode (850nm, 550m, LC) |
| SFP-GE-T | SFP GE Copper Interface Transceiver Module (100m,RJ45) |
| SFP-XG-LX-SM1310 | SFP+ Module(1310nm,10km,LC) |
| SFP-XG-SX-MM850-E | SFP+ Module(850nm,300m,LC) |
| Static Mac address | 1K |
| Storage Temperature | -40℃ ~ 70℃ |
| Switching Capacity | 128Gbps |
| Total Power Consumption | MIN:; AC: 16W; MAX:; AC: 23W |
| Traffic Control | 802.3x traffic control and half-duplex backpressure |
| Traffic statistic | Sflow |
| US500-24G4F | H3C US500-24G4F Ethernet Switch with 24*10/100/1000BASE-T Ports and 4*1000BASE-X SFP Ports,(AC) |
| US500-24G4XF | H3C US500-24G4XF Ethernet Switch with 24*10/100/1000BASE-T Ports and 4*1G/10G BASE-X SFP Plus Ports,(AC) |
| US500-24G4XF-HP | H3C US500-24G4XF-HP Ethernet Switch with 24*10/100/1000BASE-T PoE+ Ports and 4*1G/10G BASE-X SFP+ Ports,(AC) |
| US500-24G4XF-HP — 375W | 15.4W (802.3af): 24; 30W (802.3at): 12 |
| US500-48G4F | H3C US500-48G4F Ethernet Switch with 48*10/100/1000BASE-T Ports and 4*1000BASE-X SFP Ports,(AC) |
| US500-48G4XF | H3C US500-48G4XF Ethernet Switch with 48*10/100/1000BASE-T Ports and 4*1G/10G BASE-X SFP Plus Ports,(AC) |
| US500-48G4XF-HP | H3C US500-48G4XF-HP Ethernet Switch with 48*10/100/1000BASE-T PoE+ Ports and 4*1G/10G BASE-X SFP+ Ports,(AC) |
| US500-48G4XF-HP — 375W | 15.4W (802.3af): 24; 30W (802.3at): 12 |
| US500-8G24F4XF | H3C US500-8G24F4XF-S Ethernet Switch with 24*100/1000Base-X Ports and 8*10/100/1000Base-T Combo Ports and 4*1G/10GBase-X SFP Plus Ports, Without Power Supplies |
| VLAN | Port-based VLAN; MAC-based VLAN; Protocol-based VLAN; QinQ and selective QinQ; VLAN mapping; Voice VLAN; MVRP |
| VLAN interface | Both IPv4 and IPv6 supported |
| Weight | ≤ 2.4 kg |
Answers to the questions that the recorded characteristics of US500 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Safety": UL 62368-1; CAN/CSA C22.2 No 62368-1; IEC 62368-1; EN 62368-1; AS/NZS 62368-1; FDA 21 CFR Subchapter J; GB 4943.1.
Yes — recorded under "IRF2": Distributed device management, distributed link aggregation, and distributed resilient routing; Stacking through standard Ethernet interfaces; Local device stacking and remote device stacking.
-5℃ ~ 50℃(normal operating temperature); -5℃ ~ 45℃(When using transceiver modules with maximum transmission distance < 80km); -5℃ ~ 40℃(When using transceiver modules with maximum transmission distance ≥ 80km) (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Layer 3 Gigabit managed access Ethernet switch

H3C Layer 3 Gigabit Access Switch Series

H3C Series Converged Gigabit Switches

30 Port SFP+ Layer 3 Managed Industrial Ethernet Switch

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | US500 |
| Manufacturer | H3C |
Core and Aggregation Switches
Gigabit Managed Layer 3 Switch with 4 SFP Ports · Ref. : DGS-3312SR
Price on request
Core and Aggregation Switches
24-port Layer 3 PoE+ switch with 2.5 GbE and 10G SFP+ · Ref. : USW-ENTERPRISE-24-POE
Price on request
Core and Aggregation Switches
IP65 high bay dual sense presence sensor HF and PIR · Ref. : HIM30-B-L2
Price on request
Core and Aggregation Switches
28-port GbE L3 aggregation switch with 4 SFP+ uplinks
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details