HNFPA-1 – Near-field magnetic and electric field probe set 9 kHz-3 GHz
Near-field magnetic and electric field probe set 9 kHz-3 GHz
- Figure below
- Other
- SMA Female to N Male*2
- Approx. 66*48*16mm
- Manufacturer part number
- 9KHZ
- Manufacturer
- Hantek
- A mplitude-frequency C urve
- Figure below
- Adapter (cable connector)
- N (male) - SMA (female) type
Hantek passive near-field probe set for EMC pre-compliance and locating electromagnetic interference sources, from 9 kHz to 3 GHz, with a preamplifier providing about 30 dB gain.
- HNFPA-1 preamplifiers frequency range9kHz-3GHz, with a gain of approx. 30dB;
- A mplitude-frequency C urveFigure below
- Select — Series — Bandwidth — Channels — Sampling RateOther
- Adapter (cable connector)N (male) - SMA (female) type
- AdaptorSMA Female to N Male*2
- D imensionApprox. 66*48*16mm
Product overview
Hantek HNFP Series Near-Field Probes. The Hantek HNFP near-field probe set is a passive EMC pre-compliance system for troubleshooting electromagnetic interference (EMI) and checking EMC before sending a product for conformance testing.
Main characteristics. The set includes seven magnetic field (H) probes, five high-frequency probes (30 MHz to 3 GHz for HNFP-1 to HNFP-4 and HNFP-9, HNFP-8 up to 1.5 GHz) and three low-frequency probes, plus two high-frequency electric field (E) probes from 30 MHz to 3 GHz. The electrically isolated probe heads have different shapes suited to different near-field measurement tasks. HNFP-5 and HNFP-6 cover 1 MHz to 50 MHz, HNFP-7 covers 9 kHz to 1.5 MHz. The overall frequency range is 9 kHz to 3 GHz. Flatness is ±1.5 dB. Large loops are more sensitive but have lower spatial resolution, small loops the reverse.
Interfaces and connectivity. The probes are passive and connect directly to a spectrum analyzer, oscilloscope or receiver through a 50 Ω cable. The HNFPA-1 preamplifier covers 9 kHz to 3 GHz with a typical gain of 30 dB, a maximum input power of 15 dBm and a maximum linear output power of 10 dBm. Its input-output interface is SMA female, the port format is SMB, and it operates at DC 12 V through a supplied power adapter with Type-C charging cable. A 1 m SMA male to SMB female RF cable is supplied.
Typical uses. These probes locate the sources of interfering electric and magnetic fields precisely, test low-frequency conducted interference and improve measurement sensitivity when the interference signal is weak, using the preamplifier.
Integration. To use the HNFPA-1 or the probes with the preamplifier, an SMA male to SMA male RF cable is required and must be provided by the customer. The probes are available on quotation from Atlas Electronics.
Highlights
- A mplitude-frequency C urve: Figure below
- Adapter (cable connector): N (male) - SMA (female) type
- Adaptor: SMA Female to N Male*2
- D imension: Approx. 66*48*16mm
- F latness: ±1.5dB
- F requency R ange: 9KHz-3GHz
Technical questions
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for 9KHZ, with where it comes from. Use the filters to find one quickly.
All specifications (34)
| Characteristic | Value |
|---|---|
| A mplitude-frequency C urve | Figure below |
| Adapter (cable connector) | N (male) - SMA (female) type |
| Adaptor | SMA Female to N Male*2 |
| D imension | Approx. 66*48*16mm |
| F latness | ±1.5dB |
| F requency R ange | 9KHz-3GHz |
| Frequency Ranges | Low Frequency: 9kHz to 50MHz High Frequency: 30MHz to 3GHz |
| High Frequency Electric Field Probes (30MHz to 3GHz) — 30MHz~3GHz — 2 probe shapes — -- | Accurate testing of electric field (E); Electromagnetic compatibility rectification with precise location of electric field interference sources |
| HNFP-1 | Frequency range: 30MHz-3GHz |
| HNFP-2 | Frequency range: 30MHz-3GHz |
| HNFP-3 | Frequency range: 30MHz-2GHz |
| HNFP-4 | Frequency range: 30MHz-3GHz |
| HNFP-5 | Magnetic field near-field probe to check magnetic fields within 10cm.; Mainly used for low frequency conduction rectification testing.; Frequency range: 1MHz to 50MHz.; Resolution: 25mm or so. |
| HNFP-6 | Magnetic field near-field probe to check magnetic fields within 3cm.; Mainly used for low frequency conduction rectification testing.; Frequency range: 1MHz to 50MHz.; Resolution: 10mm or so. |
| HNFP-7 | Magnetic field near-field probe to check magnetic fields within 10cm.; Mainly used for low frequency conduction rectification testing.; Frequency range: 9kHz to 1.5MHz.; Resolution: 25mm or so. |
| HNFP-8 | Frequency range: 30MHz-1.5GHz |
| HNFP-9 | Frequency range: 30MHz-3GHz |
| HNFPA-1 | Frequency range: 9KHz-3GHz |
| HNFPA-1 preamplifiers frequency range | 9kHz-3GHz, with a gain of approx. 30dB; |
| HNFPA-1 RF Amplifier | Mainly amplifies the weak signals to be tested, with a gain of about 30 dB. |
| HSA2016 Series — 9KHz-1.6GHz — RF IN + TG OUT — -- | Frequency range; 9KHz-1.6GHz,; Sensitivity -161dBm,; RBW:10Hz~1MHz,; FMAM audio demodulator; frequency counter |
| HSA2030 Series — 9KHz-3.2GHz — RF IN + TG OUT — -- | Frequency range; 9KHz-3.2GHz,; Sensitivity -161dBm,; RBW:10Hz~1MHz,; FMAM audio demodulator; frequency counter |
| I nput- O utput interface | SMA (Female); Note: If this product is used with our Field Probes,customer need to prepare SMA(male) to SMA(male) RF cables for testing. |
| M odel | HNFPA-1 |
| Maximum Input Power | 15dBm |
| Maximum L inear O utput P ower | 10dBm |
| O perating V oltage | DC12V |
| Port Format | SMB (male) type |
| Power Adapter | Power Adapter*1, Type-C Charging Cable*1 |
| Radio Frequency Cables | SMA (male) - SMB (female) type, 1m; Note: If this product is used with our HNFPA-1 amplifier,customer need to prepare SMA(male) to SMA(male) RF cables for testing. |
| RF Cable | Approx. 1m in length, input port with near-field probe*1 |
| Select — Series — Bandwidth — Channels — Sampling Rate | Other |
| Typical Gain | 30dB |
| Typical noise figure @2GHz | 4dB |
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for 9KHZ. For a missing document or a specific revision, our experts send it to you.
Contents
Overview Datasheet extract Official documents1. Technical overview
Hantek passive near-field probe set for EMC pre-compliance and locating electromagnetic interference sources, from 9 kHz to 3 GHz, with a preamplifier providing about 30 dB gain.
2. Datasheet extract (recorded values)
| Parameter | Value |
|---|---|
| A mplitude-frequency C urve | Figure below |
| Adapter (cable connector) | N (male) - SMA (female) type |
| Adaptor | SMA Female to N Male*2 |
| D imension | Approx. 66*48*16mm |
| F latness | ±1.5dB |
| F requency R ange | 9KHz-3GHz |
| Frequency Ranges | Low Frequency: 9kHz to 50MHz High Frequency: 30MHz to 3GHz |
| High Frequency Electric Field Probes (30MHz to 3GHz) — 30MHz~3GHz — 2 probe shapes — -- | Accurate testing of electric field (E); Electromagnetic compatibility rectification with precise location of electric field interference sources |
| HNFP-1 | Frequency range: 30MHz-3GHz |
| HNFP-2 | Frequency range: 30MHz-3GHz |
| HNFP-3 | Frequency range: 30MHz-2GHz |
| HNFP-4 | Frequency range: 30MHz-3GHz |
| HNFP-5 | Magnetic field near-field probe to check magnetic fields within 10cm.; Mainly used for low frequency conduction rectification testing.; Frequency range: 1MHz to 50MHz.; Resolution: 25mm or so. |
| HNFP-6 | Magnetic field near-field probe to check magnetic fields within 3cm.; Mainly used for low frequency conduction rectification testing.; Frequency range: 1MHz to 50MHz.; Resolution: 10mm or so. |
| HNFP-7 | Magnetic field near-field probe to check magnetic fields within 10cm.; Mainly used for low frequency conduction rectification testing.; Frequency range: 9kHz to 1.5MHz.; Resolution: 25mm or so. |
| HNFP-8 | Frequency range: 30MHz-1.5GHz |
| HNFP-9 | Frequency range: 30MHz-3GHz |
| HNFPA-1 | Frequency range: 9KHz-3GHz |
| HNFPA-1 preamplifiers frequency range | 9kHz-3GHz, with a gain of approx. 30dB; |
| HNFPA-1 RF Amplifier | Mainly amplifies the weak signals to be tested, with a gain of about 30 dB. |
| HSA2016 Series — 9KHz-1.6GHz — RF IN + TG OUT — -- | Frequency range; 9KHz-1.6GHz,; Sensitivity -161dBm,; RBW:10Hz~1MHz,; FMAM audio demodulator; frequency counter |
| HSA2030 Series — 9KHz-3.2GHz — RF IN + TG OUT — -- | Frequency range; 9KHz-3.2GHz,; Sensitivity -161dBm,; RBW:10Hz~1MHz,; FMAM audio demodulator; frequency counter |
| I nput- O utput interface | SMA (Female); Note: If this product is used with our Field Probes,customer need to prepare SMA(male) to SMA(male) RF cables for testing. |
| M odel | HNFPA-1 |
| Maximum Input Power | 15dBm |
| Maximum L inear O utput P ower | 10dBm |
| O perating V oltage | DC12V |
| Port Format | SMB (male) type |
| Power Adapter | Power Adapter*1, Type-C Charging Cable*1 |
| Radio Frequency Cables | SMA (male) - SMB (female) type, 1m; Note: If this product is used with our HNFPA-1 amplifier,customer need to prepare SMA(male) to SMA(male) RF cables for testing. |
| RF Cable | Approx. 1m in length, input port with near-field probe*1 |
| Select — Series — Bandwidth — Channels — Sampling Rate | Other |
| Typical Gain | 30dB |
| Typical noise figure @2GHz | 4dB |
Compliance, lifecycle and traceability
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
Lifecycle and product statusStatus not stated
- In production
- Not recommended for new designs
- End of life
- Obsolete
| Current status | Status not stated |
| Key dates | Not recorded |
Manufacturer references
| Manufacturer part number | 9KHZ |
| Manufacturer | Hantek |