HX-CSX231A – High precision active multi-band GNSS antenna

High precision active multi-band GNSS antenna

Combination Multi-Band Antennas

  • -40℃ to +85℃
  • ≤ 45mA
  • -55℃ to +85℃
  • Φ 90*H21.8mm
Manufacturer part number
CSX231A
Manufacturer
Harxon
Operating Temperature
-40℃ to +85℃
Operation Current
≤ 45mA

Harxon HX-CSX231A active full band GNSS antenna for satellite positioning signal reception. It targets survey base and rover stations, robots and autonomous vehicles.

Product overview

Overview. The Harxon HX-CSX231A active GNSS antenna is a high gain, compact full band antenna designed to provide reliable and consistent positioning. It is described as suited to high dynamic applications such as small robots and autonomous vehicles.

Main characteristics. It offers a peak gain of 4.5 dBi, right-hand circular polarization (RHCP), 360° azimuth coverage and an axial ratio of 3 dB or less. Its phase center error is ±2 mm. The noise figure is 2 dB or less and the output VSWR 2.0 or less.

Signal reception. The antenna receives GPS L1/L2/L5, GLONASS L1/L2/L3, Galileo E1/E5a/E5b/E6, BDS B1I/B2I/B3I/B1C/B2a/B2b, QZSS L1/L2/L5/L6 and IRNSS L5 signals. LNA gain is 28 ±2 dB on L1 and 30 ±2 dB on L2. The nominal impedance is 50 Ω.

Power and environment. The operating voltage ranges from +3.3 to +12 VDC, with an operating current of 45 mA or less. The operating temperature range is -40 °C to +85 °C, the storage temperature -55 °C to +85 °C, and the humidity tolerance is 95% non-condensing.

Mechanical and connectivity. Dimensions are Φ 90 × H 21.8 mm. The connector is an SMA female (SMA-J).

Integration. The antenna integrates with precision positioning systems, including base stations, rover stations and agricultural and robotic applications. Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Azimuth Coverage: 360°
  • Connector: SMA-J
  • Humidity: 95% non-condensing
  • Nominal Impedance: 50&Omega
  • Operating Temperature: -40℃ to +85℃
  • Operation Voltage: +3.3 to +12VDC

Good to know before integrating

  • Thermal: rated operating range -40℃ to +85℃ — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.