HX-SE409A – Multi-constellation GNSS antenna with integrated 4G

Multi-constellation GNSS antenna with integrated 4G

Combination Multi-Band Antennas

  • -40℃ to +85℃
  • ≤ 45mA
  • -55℃ to +85℃
  • Φ 111.0*H19.8mm
Manufacturer part number
SE409A
Manufacturer
Harxon
Operating Temperature
-40℃ to +85℃
Operation Current
≤ 45mA

Multi-band GNSS antenna combined with a 4G antenna in one compact enclosure, designed for precision positioning in surveying and robotics.

Product overview

Harxon HX-SE409A is an embedded multi-constellation, multi-frequency GNSS antenna that integrates a 4G antenna in one compact enclosure, classified among combination multi-band antennas. Overview — The antenna receives GPS L1/L2/L5, GLONASS L1/L2/L3, Galileo E1/E5a/E5b/E6, BDS B1I/B2I/B3I/B1C/B2a/B2b, QZSS L1/L2/L5/L6, IRNSS L5 and L-band signals, with RHCP polarization and 360° azimuth coverage.

Main characteristics. The phase center is stable, with a deviation of ±2 mm, a phase center height of 17.1 mm on L2 and 20.1 mm on L1, an axial ratio of 2 dB or less and a GNSS peak gain of 5.5 dBi. The LNA gain is 30±2 dB, with a noise figure of 2 dB or less, a passband ripple of ±2 dB and a differential propagation delay of 5 ns or less. The enclosure measures Ø 111.0 × H 19.8 mm for a weight of 80.5 g.

Interfaces and connectivity. The GNSS connector is an MMCX-JW and the 4G connector an IPEX Generation 1. The nominal impedance is 50 Ω and the output VSWR is 2.0 or less.

Power and environment. Power supply ranges from +3.3 to +12 VDC, with an operating current of 45 mA or less. The operating temperature range is -40 °C to +85 °C, the storage range -55 °C to +85 °C, with 95% non-condensing humidity tolerance.

Typical uses. Survey base and rover stations, agriculture and robotics, where precise positioning and 4G connectivity are needed in the same volume. Available on quotation from Atlas Electronics.

Integration. The integrated enclosure simplifies installation in space-constrained applications.

See all specifications

Highlights

  • Azimuth Coverage: 360°
  • Humidity: 95% Non-condensing
  • LNA Gain: 30±2dB
  • Nominal Impedance: 50&Omega
  • Operating Temperature: -40℃ to +85℃
  • Operation Voltage: +3.3 to +12VDC

Good to know before integrating

  • Thermal: rated operating range -40℃ to +85℃ — check it against the installation environment.