Heltec HT-M7603 indoor LoRaWAN gateway bridging a LoRa network to an IP network via Wi-Fi or Ethernet, wall-mountable or usable as a blind filling gateway.
Operating Temperature-20 ~ 70℃
Supply voltage+5V
The power supply voltage5V
Frequency470~510/863~870/902~923MHz
Ethernet10/100M
Dimensions116*65*30 mm
Product overview
Overview. The Heltec HT-M7603 is a cost-effective indoor standard LoRaWAN gateway, usable on its own or as a blind filling gateway. It bridges LoRa wireless networks to IP networks and different network servers via Wi-Fi or Ethernet, with simple configuration.
Main characteristics. The device is built around an MTK7628 MCU with SX1303 and SX1250 chips. It provides eight uplink channels and one downlink channel, with receive sensitivity of -125 dBm at 125 kHz/SF7 and -139 dBm at 125 kHz/SF12, and a maximum transmit power of +27 ± 2 dBm. It supports LoRaWAN Class A and Class C as well as custom MQTT protocols.
Frequency bands. Three versions exist: 470~510 MHz, 863~870 MHz and 902~928 MHz. The operating band cannot be switched freely, as each version requires different impedance matching: CN470 for the 470~510 MHz version, EU868 and IN865 for the 863~870 MHz version, and US915, AU915, AS923, LA915 and KR920 (LBT) for the 902~928 MHz version.
Interfaces and connectivity. The gateway provides a 10/100M Ethernet port and IEEE 802.11 b/g/n Wi-Fi in the 2.4 GHz band. Switching between LoRaWAN and custom MQTT operation is done by selecting the gateway mode.
Power and environment. It is powered at 5 V and does not accept power through its USB Type-C port. It operates from -20 to 70 °C at 10% to 90% humidity, non-condensing. Dimensions are 116 × 65 × 30 mm for a weight of 100 g.
Installation. A wall fixing kit allows the device to be mounted easily indoors. Configuration consists of powering on, setting up the network, then connecting to a LoRaWAN network server.
Heltec HT-M7603 indoor LoRaWAN gateway bridging a LoRa network to an IP network via Wi-Fi or Ethernet, wall-mountable or usable as a blind filling gateway.
Operating Temperature-20 ~ 70℃
Supply voltage+5V
The power supply voltage5V
Frequency470~510/863~870/902~923MHz
Ethernet10/100M
2. Datasheet extract (recorded values)
Parameter
Value
Dimensions
116*65*30 mm
Supply voltage
+5V
Ethernet
10/100M
Frequency
470~510/863~870/902~923MHz
LoRa Band
470~510MHz, 863~870MHz, 902~928MHz
LoRa chipset
SX1303 + SX1250
LoRa RX sensitivity
-125dBm @125KHz/SF7; -139dBm @125KHz/SF12
Max Tx Power
+27 ± 2dBm
Maximum Output
27 ± 2dBm
MCU
MTK7628
Multi-channel
Eight (8) uplink, one (1) downlink.
Operating Humidity
10%~90%, no-condensing
Operating Temperature
-20 ~ 70℃
The power supply voltage
5V
Weight
100 g
Wi-Fi
IEEE 802.11 b/g/n 2.4GHz
Integration
Points to check before using HT-M7603 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with +5V.
2Thermalrated operating range -20 ~ 70℃ — check it against the installation environment.
3Powerplan for a supply compatible with 5V.
Power and communication
Supply voltage
+5V
Max Tx Power
+27 ± 2dBm
The power supply voltage
5V
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with +5V.
Thermal : rated operating range -20 ~ 70℃ — check it against the installation environment.
Power : plan for a supply compatible with 5V.
Applications and use cases
Architectures in which HT-M7603 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
A leak under a sink or in a technical room is often found days later. Leak detection places wireless sensors where water can appear and sends an alert through a gateway as soon as one of them gets wet
To check
Locations at risk: kitchens, bathrooms, plant rooms, server rooms
Alert path (SMS, e-mail, application) and who receives it
Battery life and the way a low battery is reported
A fridge that drifts at night can ruin a whole stock. Temperature loggers in cold rooms and trucks report through a gateway or a tracker and raise an alert when a threshold is crossed
To check
Temperature range and accuracy required by the product
Record keeping required by the applicable regulations
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Need a complete solution?
Send a request for HT-M7603 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details