HG808-H – High humidity and temperature transmitter RS485 4-20mA

High humidity and temperature transmitter RS485 4-20mA

Temperature, Humidity & Gas Sensors

  • <20mA
  • < 0.5W
  • -40 ~ 80℃
  • ± 0.1 ℃
Manufacturer part number
HG808-H
Manufacturer
HENGKO
Current consumption
<20mA
Power consumption
< 0.5W

The HENGKO HG808-H is an industrial humidity and temperature transmitter designed for very humid environments up to 100% RH. It provides an RS485 Modbus output and analog signals.

Product overview

Overview. The HENGKO HG808-H is an industrial humidity and temperature transmitter, model HG808-H, designed for measurement in high-humidity environments up to 100% RH, with a recommended range below 95% RH. It also measures temperature and calculates dew point.

Measurement characteristics. Humidity accuracy is ±2% RH at 20 °C for 10 to 90% RH, and temperature accuracy is ±0.1 °C at 20 °C. Dew point accuracy is ±2 °C Td. Resolution is 0.1 °C and 0.1% RH, with an optional 0.01 °C and 0.01% RH. The temperature range is -40 to +100 °C.

Interfaces and connectivity. The RS485 digital output (MODBUS) transmits temperature, humidity, dew point and ppm simultaneously, at baud rates from 1200 to 115200 bps (9600 bps by default), with 8 data bits, 1 stop bit and no parity. The model also supports IIC. Combined analog outputs are RS485 + 4-20mA, RS485 + 0-5 V or RS485 + 0-10 V.

Power and environment. Power supply is 10 to 28 V DC, consumption is below 20 mA and power below 0.5 W. Operating temperature is -20 to +60 °C, 10 to 95% RH non-condensing, and storage temperature is -40 to +80 °C. The housing reaches IP65 protection, and the 316/316L stainless steel probe is available in split or pipeline versions, with a pressure rating of 16 bar.

Typical uses. The transmitter suits continuous humidity monitoring in wet environments, for example drying chambers, with integration into PLCs through the RS485 Modbus link.

See all specifications

Highlights

  • Humidity accuracy: ±2% RH (@ 20°C, 10 ~ 90% RH)
  • Current consumption: <20mA
  • Humidity range: 0 ~ 100% RH (Recommend < 95% RH)
  • Accuracy — ± 0 .1℃ — ±1.5%RH: ± 0.1 ℃
  • Baud rate: 1200, 2400, 4800, 9600, 19200, 115200 (default: 9600 bps)
  • Byte Format: 8 data bits, 1 stop bit, no check

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -20 ~ 60℃ 10 ~ 95 RH non-condensing — check it against the installation environment.

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.