The HXE12DL is a direct-connected single-phase static electricity meter from Hexing for residential metering. It measures active energy at Class 1 accuracy with an IEC 62056-21 optical interface.
Temperature — Operating Temperature-40 ℃ ~70 ℃
Operating Voltage Range80%-120%
Storage & Transport Temp. Range-40 ℃ ~70 ℃
Communication Interfaces — Optical PortIEC62056-21
Current — Base Current5A
Current Circuit≤1VA
Product overview
Overview. The Hexing HXE12DL is a direct-connected single-phase static electricity meter, part of the manufacturer's new generation of residential meters. It is designed to meet practical user needs with a high performance-to-price ratio.
Main characteristics. The meter is Class 1 for active energy and Class 2 for reactive energy. Its base current is 5 A, with maximum currents of 60 A and 100 A, an operating voltage range of 80% to 120% and rated voltages of 120 V to 240 V. Its frequency is 50 Hz or 60 Hz, and its starting current is at most 0.4% Ib.
Interfaces and connectivity. The HXE12DL has an optical port compliant with IEC 62056-21. The manufacturer also indicates an optional RS485 port on the HXE12DL and HXE13DL range.
Power and environment. The voltage circuit consumes at most 2 W active and 10 VA apparent, and the current circuit at most 1 VA. The enclosure is rated IP54, protection class II, with an operating temperature range of -40 ℃ to 70 ℃ and tolerance up to 95% relative humidity, non-condensing. Dimensions are 125 mm x 132 mm x 50 mm for a net weight of approximately 0.4 kg.
Tests and standards. The meter complies with IEC 62052-11, IEC 62053-21 and IEC 62056-21. It withstands a 4 kV AC dielectric test for 1 minute, a 6 kV impulse voltage, a 4 kV electrical fast transient/burst test, electrostatic discharge of 15 kV in air and 8 kV by contact, and radiated RF immunity of 10 V/m with current and 30 V/m without current.
Typical uses. This meter suits monophasic energy consumption metering in residential installations, connected directly to the network.
The HXE12DL is a direct-connected single-phase static electricity meter from Hexing for residential metering. It measures active energy at Class 1 accuracy with an IEC 62056-21 optical interface.
Temperature — Operating Temperature-40 ℃ ~70 ℃
Operating Voltage Range80%-120%
Storage & Transport Temp. Range-40 ℃ ~70 ℃
Communication Interfaces — Optical PortIEC62056-21
Current — Base Current5A
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy Class — Active Energy
Class 1
Base
Cold Gray PC
Communication Interfaces — Optical Port
IEC62056-21
Connection Type
Direct-Connected
Cover
Cold Gray PC, Clear Viewing Window
Current — Base Current
5A
Current Circuit
≤1VA
Dielectric Strength — AC Voltage Test
4kV for 1 min
Dimensions (Length/Width/Height)
125mm x 132 mm x 50 mm
Electrical Fast Transient/Burst Test
4kV
Electrostatic Discharge (Air Discharge)
15kV
EMC — Electrostatic Discharge (Contact Discharge)
8kV
Enclosure — IP Rating
IP54
Frequency
50Hz, 60Hz
Humidity
Up to 95% Relative Humidity (Non-condensing)
Impulse Voltage Test
1.2/50µs 6kV
Maximum Current
60A, 100A
Operating Voltage Range
80%-120%
Packaging:
Approx. 0.06kg
Power Consumption — Voltage Circuit (Active)
≤2W
Protection Class
Class II
Radiated RF Electromagnetic Field Immunity Test (80 MHz to 2000 MHz)
10V/m (with current) 30V/m (without current)
Reactive Energy
Class 2
Standards
IEC62052-11, IEC62053-21, IEC62056-21
Starting Current
≤0.4%Ib
Storage & Transport Temp. Range
-40 ℃ ~70 ℃
Surge Immunity Test
5kV
Temperature — Operating Temperature
-40 ℃ ~70 ℃
Terminal Cover
Transparent PC
Terminal Dimensions
10mm x 9mm
Voltage Circuit (Apparent)
≤10 VA
Voltage — Rated Voltage
120V~ 240V
Weight — Net Weight
Approx. 0.4kg
Integration
Points to check before using HXE12DL in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40 ℃ ~70 ℃ — check it against the installation environment.
Power and communication
Current — Base Current
5A
Current Circuit
≤1VA
Dielectric Strength — AC Voltage Test
4kV for 1 min
Impulse Voltage Test
1.2/50µs 6kV
Maximum Current
60A, 100A
Operating Voltage Range
80%-120%
Power Consumption — Voltage Circuit (Active)
≤2W
Starting Current
≤0.4%Ib
Voltage Circuit (Apparent)
≤10 VA
Voltage — Rated Voltage
120V~ 240V
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40 ℃ ~70 ℃ — check it against the installation environment.
Applications and use cases
Architectures in which HXE12DL can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Solar panels produce most when nobody is home, and the surplus goes to the grid. A battery with its inverter stores this energy and returns it in the evening, with a meter measuring what the home draws
To check
Panel power and the inverter compatibility of the battery
Usable capacity compared with the evening and night consumption
Local grid connection rules for balcony and home systems
Associated system blocks
InvertersBatteryMetering
Need a complete solution?
Send a request for HXE12DL and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details