VCB4805SBO – Isolated DC/DC power module 20 W, 1/16 brick format

Isolated DC/DC power module 20 W, 1/16 brick format

Non-Isolated DC/DC Converters

  • ℃
  • -40 ° Cto+85 ° C
  • 36V~75V
  • mA
Manufacturer part number
VCB4805SBO
Manufacturer
HLK Tech
Working Temperature Range
-40 ° Cto+85 ° C
Wide input voltage range
36V~75V

Isolated DC/DC power module in 1/16 brick format, 20 W, with a wide 36 V to 75 V input range, intended for telecommunications equipment.

Product overview

Overview. The HLK Tech VCB4805SBO is an isolated DC/DC power module in 1/16 brick format, an isolated 20 W DC/DC converter. It belongs to the VCB48_SBO-20WR3 series.

Main characteristics. Output power is 20 W, efficiency reaches 90 %, and the input range is wide, from 36 V to 75 V. The input-to-output isolation voltage is 1500 VDC and the operating temperature range is -40 °C to +85 °C.

Connectivity and control. The Ctrl remote control pin enables the module when left floating or connected to a TTL high level (3.5 to 12 VDC), and shuts it down when connected to GND or a low level (0 to 1.2 VDC).

Power and environment. Input current is 474 mA at full load and 15 mA at no load for the rated input voltage, with input undervoltage protection. Storage temperature ranges from -55 °C to +125 °C and storage humidity from 5 % to 95 % RH, non-condensing. MTBF is 1000 K hours per MIL-HDBK-217F at 25 °C.

Protections. The module provides output overcurrent protection, continuous short-circuit protection with auto-recovery, and output overvoltage protection.

Typical uses. This module suits DC power supplies for switches, repeaters, intelligent communication gateways, GPS clock synchronization equipment and 4G/5G base stations, as stated by the manufacturer.

See all specifications

Highlights

  • Hot-swapping: Non support
  • Impulse voltage (1sec. max) — -0.7 — - — 100: VDC
  • Input current (full load/no load) — Rated input voltage — - — 474/15 — 485/30: mA
  • Input filter type: Capacitive filtering
  • Input undervoltage protection — 28 — 31 — -: VDC
  • Input Voltage Range — 110 — 150 — 190: %lo

Good to know before integrating

  • Thermal: rated operating range ℃ — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.