The Holykell 4811 wireless magnetic flow meter measures instantaneous flow and velocity in DN10 to DN1600 pipes and transmits flow data remotely for water volume monitoring.
Flow Measurement range0---15 m /sec
Record parametersTotal traffic accumulation
Applicable measurement pathDN10---DN1600
Communication modeRS485 (modbus protocol),GPRS, CDMA
Matching precision level0.5
Protection GradeIP68
Product overview
Holykell 4811. The Holykell 4811 wireless magnetic flow meter is a magnetic flow meter for measuring the flow rate and velocity of liquids in pipes from DN10 to DN1600.
Measurement. It provides instantaneous flow rate and instantaneous velocity, with recording of total accumulated volume. The velocity measurement range is 0 to 15 m/s, with a matching precision level of 0.5.
Connectivity. It communicates over RS485 with Modbus protocol, and over GPRS or CDMA. Optional wireless networks include GPRS, 4G, NB-IoT or LoRa.
Alarms and diagnostics. Alarms detect an empty fluid tube and an excitation current fault.
Power and environment. It is powered by a lithium battery with intelligent power-saving technology, with a battery life of up to 3 years. Its protection grade is IP68, the working temperature range is -25 to 50 ℃ and the working humidity is at most 95 %.
Typical uses. It suits direct drinking water supply systems, sewage discharge control, wastewater purification, fire water pipeline level control and agricultural irrigation.
Integration. Automatic two-way flow measurement with forward and reverse cumulative flow display, together with wireless transmission of flow data, supports real-time monitoring of water volumes. This model is available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for 4811_WIRELESS_MAGNETIC_FLOW_METER, with where it comes from. Use the filters to find one quickly.
All specifications (11)
Characteristic
Value
Applicable measurement path
DN10---DN1600
Communication mode
RS485 (modbus protocol),GPRS, CDMA
Detection alarm parameters
Fluid air tube detection alarm, excitation current detection alarm
Flow Measurement range
0---15 m /sec
Matching precision level
0.5
Measuring Parameters
Instantaneous flow rate, instantaneous velocity
Protection Grade
IP68
Record parameters
Total traffic accumulation
Wireless Network Mode
GPRS/4G/NB-ioT/Lora optional
Working Environment Humidity
≦95%
Working temperature
-25~50℃
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for 4811_WIRELESS_MAGNETIC_FLOW_METER. For a missing document or a specific revision, our experts send it to you.
The Holykell 4811 wireless magnetic flow meter measures instantaneous flow and velocity in DN10 to DN1600 pipes and transmits flow data remotely for water volume monitoring.
Flow Measurement range0---15 m /sec
Record parametersTotal traffic accumulation
Applicable measurement pathDN10---DN1600
Communication modeRS485 (modbus protocol),GPRS, CDMA
Matching precision level0.5
2. Datasheet extract (recorded values)
Parameter
Value
Applicable measurement path
DN10---DN1600
Communication mode
RS485 (modbus protocol),GPRS, CDMA
Detection alarm parameters
Fluid air tube detection alarm, excitation current detection alarm
Flow Measurement range
0---15 m /sec
Matching precision level
0.5
Measuring Parameters
Instantaneous flow rate, instantaneous velocity
Protection Grade
IP68
Record parameters
Total traffic accumulation
Wireless Network Mode
GPRS/4G/NB-ioT/Lora optional
Working Environment Humidity
≦95%
Working temperature
-25~50℃
Applications and use cases
Architectures in which 4811_WIRELESS_MAGNETIC_FLOW_METER can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Answers to the questions that the recorded characteristics of 4811_WIRELESS_MAGNETIC_FLOW_METER can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Communication mode": RS485 (modbus protocol),GPRS, CDMA.
2Does it support Modbus?
Yes — recorded under "Communication mode": RS485 (modbus protocol),GPRS, CDMA.
3Does it support 4G/LTE?
Yes — recorded under "Wireless Network Mode": GPRS/4G/NB-ioT/Lora optional.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details