The HR1200 is a 60 GHz radar level sensor with non-contact measurement, used for liquid level monitoring in tanks and vessels. It communicates over RS485 Modbus RTU.
Measuring Range0.2-12m for water; 0.2-8m for diesel
Center frequency60 GHz
Frequency1~10 Hz
Scanning frequency1-10 Hz
Measurement Accuracy±2mm
Communication modeRS485 MODBUS RTU
Product overview
Overview. The Holykell HR1200 is a 60 GHz millimeter wave radar level sensor. Its non-contact measurement stays clean and requires little maintenance, and its bubble spirit level design makes installation straightforward.
Main characteristics. Center frequency of 60 GHz, FOV angle of 8°, 15 mm lens antenna and measurement accuracy of ±2 mm. The measuring range is 0.2 to 12 m for water and 0.2 to 8 m for diesel. Scanning frequency is 1 to 10 Hz.
Interfaces and connectivity. The sensor uses the RS485 MODBUS RTU protocol. The default communication rate is 115200 bit/s, with 9600, 19200 or 38400 bit/s selectable.
Power and environment. Recommended power supply of 12 V DC, with 9 to 24 V DC available. Power consumption from 0.2 W minimum to 0.45 W maximum. Operational temperature from -40 to +85 ℃, protection class IP68. Dimensions Ø73 × 82 mm, weight 440.5 g excluding the connection wire.
Typical uses. Water treatment, water tank measurement, petrochemical storage tanks, pharmaceutical industry, food and beverage manufacturing, refining process vessels and hydroelectric power generation and dams.
Integration. The sensor can be connected to a host computer running the setting software, a tankside meter and other equipment.
The HR1200 is a 60 GHz radar level sensor with non-contact measurement, used for liquid level monitoring in tanks and vessels. It communicates over RS485 Modbus RTU.
Measuring Range0.2-12m for water; 0.2-8m for diesel
Minimum power:0.2 W(8V*16.847 mA); Maximum power:0.45 W(12*36.168 mA)
Power supply
12 V DC recommended (9-24 V DC available)
Product Size
Ø73*82 mm
Protection Class
IP68
Scanning frequency
1-10 Hz
Weight
440.5 g(not including the connection wire)
Applications and use cases
Architectures in which HR1200 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Meeting rooms are booked but empty, and some areas are always full. Presence sensors, radars and counting cameras measure how spaces are really used, room by room or at entrances
To check
Presence per room or counting at entrances, or both
Privacy requirements, which favour radar or anonymous counting
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
No one to occupied, report within 0.5s Manned to unoccupied, no status output in 1-2 minutes or so
DP10: Fallen state
Two level judgement "suspected fall", "fall alarm" Suspected fall - target fall detected Output status Fall alarm - alarm reported after time T is stationary
DP11: fall alarm reporting time T
Default 3 minutes, divided into 1-30 minute setting steps
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details