Overview. The Holykell passive thermocouple temperature sensor is a temperature sensor based on the thermoelectric effect. It covers a wide measuring range, from -40 to 1800 °C, with stable performance.
Main characteristics. Accuracy of 0.1%, 0.3%, 0.5% or optional. Diameter Φ4 mm, φ2 mm, φ3 mm, φ5 mm, φ6 mm or customized. Probe length 30 mm by default, 100 mm, 150 mm, 200 mm or customized. Standard cable length 1 m or customized. Plug-in installation. Process: groove rolling, SMD, etc.
Thermocouple types. Index types B, R, S, K, N, E, J and T. Temperature range: -200 to 600 °C (thermal resistor), -40 to 1200 °C (K type), 0 to 1800 °C (B type).
Connection and wiring. 2-wire, 3-wire or 4-wire connection. Cable materials PVC, silicone, Teflon or PTFE. Terminals U type, pin type or aviation type.
Typical uses. Measurement of gas and liquid temperature, measurement of solid surface temperature, and monitoring in boilers and pipelines. The 4-20 mA output allows remote transmission to a measuring system.
Integration. Simple structure. The 4-20 mA output facilitates connection to an instrument or a PLC.