UF2000B
Economic clamp-on ultrasonic flow meter for water

Limited record: this part has neither specifications nor a datasheet in the catalog yet. It is shown for reference and is not indexed.
Economic clamp-on ultrasonic flow meter for water
Holykell UF2000B clamp-on ultrasonic flow meter for measuring liquid flow in pipes, with 4-20 mA and MODBUS outputs.
Overview. The Holykell UF2000B is a clamp-on ultrasonic flow meter for measuring the flow of liquids in pipes, including liquids carrying small quantities of tiny particles.
Main characteristics. Accuracy ±1%, linearity 0.5% and repeatability 0.2%. It measures pipe sizes from 32 to 6000 mm. The mounting type is separated, wall mount.
Interfaces and connectivity. The flow output signal is available as 0~10 mA, 4~20 mA, pulse, MODBUS or HART.
Power and environment. Supply voltage AC 220 V or DC 24 V. Working temperature from -30 °C to 90 °C and high-temperature rating from -30 °C to 160 °C.
Typical uses. Measurement of water flow (hot water, chilled water, city water, sea water, waste water), chemicals such as alcohol and acids, plant effluent, beverages and liquid food, and ultra-pure liquids.
Integration. MODBUS and HART outputs allow connection to supervision systems and PLCs.
No published question about this part yet. Questions are reviewed before publication.
Official documents and the technical data recorded for UF2000B. For a missing document or a specific revision, our experts send it to you.
Holykell UF2000B clamp-on ultrasonic flow meter for measuring liquid flow in pipes, with 4-20 mA and MODBUS outputs.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Economic clamp-on ultrasonic flow meter for water

Area Velocity Flow Meter

Ultrasonic Flow

Agriculture Irrigation Flow Meter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | UF2000B |
| Manufacturer | Holykell |
Ultrasonic Flow Meters
Portable ultrasonic flow meter with clamp-on transducers
Price on request
Ultrasonic Flow Meters
Non-contact ultrasonic flow meter for industrial pipelines
Price on request
Ultrasonic Flow Meters
Portable dual-channel transit-time ultrasonic flow meter · Ref. : ORIGINAL-FACTORY-PORTABLE-ULTRASONIC-FLOW-METER-DUAL-CHANNEL-TRANSIT-TIME-CLAMP
Price on request
Ultrasonic Flow Meters
High-temperature ultrasonic flow transducer · Ref. : US0081
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details