UEB1-70
Modular miniature circuit breaker 1P/2P/3P rated 5 to 60 A

- Range
- UEB1
- Network Frequency
- 50/60Hz
- Power-frequency withstand voltage
- 2000V/1min
- Ambient Air Temperature for Storage
- -40℃~+70℃
Modular miniature circuit breaker 1P/2P/3P rated 5 to 60 A
Hongfa UEB1-70 miniature circuit breaker for AC circuit protection with thermal-magnetic tripping, intended for distribution boards. Available in 1P, 2P and 3P versions.
Overview. The Hongfa UEB1-70 is a miniature circuit breaker (MCB) from the UEB1 series, designed for AC circuit protection in distribution boards. It mounts on a DIN rail or on a mounting bracket.
Main characteristics. Rated currents of 5 A, 10 A, 15 A, 20 A, 25 A, 30 A, 35 A, 40 A, 45 A, 50 A and 60 A. Breaking capacity of 10000 A. Thermal-magnetic trip unit with local trip indicator. Toggle control. Rated voltage of 120 Va.c. / 240 Va.c. for the 1P and 2P versions, and 240 Va.c. for the 2P and 3P versions. Network frequency 50/60 Hz. Compliant with UL489.
Connections and dimensions. Terminals accept conductors from 14 AWG to 4 AWG, with a tightening torque of 3.5 N·m to 4.5 N·m. Wire connections available as box lug and box lug, or box lug and QC terminal. Width of 18.8 mm for 1P, 37.6 mm for 2P and 56.4 mm for 3P, height of 79.2 mm, depth of 102 mm.
Performance and environment. Rated insulation voltage of 690 V AC, power-frequency withstand voltage of 2000 V for 1 min, rated impulse withstand voltage of 4 kV, overvoltage category II/III. Electrical durability of 10000 cycles and mechanical durability of 20000 cycles. Operating ambient temperature from -10 ℃ to +60 ℃, storage temperature from -40 ℃ to +70 ℃, relative humidity of 90% to 95% RH below 40 ℃.
Typical uses. Protection of circuit outgoings in electrical cabinets and distribution boards on AC networks, for installations requiring a UL489 compliant breaker with a high breaking capacity.
Integration. The product complies with the EU RoHS Directive and the REACh Regulation, and is mercury free. It is available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for UEB1-70, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Ambient Air Temperature for Operation | -10℃~+60℃ |
| Ambient Air Temperature for Storage | -40℃~+70℃ |
| Breaking Capacity | 10000A |
| China RoHS Regulation | China RoHS declaration; Product out of China RoHS scope. Substance declaration for your information |
| Colour | black |
| Connections - Terminals | 14AWG-4AWG |
| Control type | Toggle |
| Depth | 102mm |
| Device Application | Distribution |
| Device Short Name | / |
| Electrical Durability | 10000 cycles |
| Environmental Disclosure | Product Environmental Profile |
| EU RoHS Directive | Compliant EU RoHS Declaration |
| Height | 79.2mm |
| Local Signalling | Trip indicator |
| Mechanical Durability | 20000 cycles |
| Mercury Free | Yes |
| Mounting Support | DIN rail、Mounting bracket |
| Net weight | 1P:153.0g、、2P: 305.5g 、3P: 457.5g |
| Network Frequency | 50/60Hz |
| Network type | AC |
| Number of Units in Package 2 | 1P:80、2P: 40、3P: 24 |
| Overvoltage category | Ⅱ/Ⅲ |
| Package Height 2 | 216mm |
| Package Length 2 | 414mm |
| Package Weight 2 | 1P:=13.7kg、2P: =13.7kg 、3P: =12.5kg |
| Package Width 2 | 282mm |
| Poles Description | 1P、2P、3P |
| Power-frequency withstand voltage | 2000V/1min |
| Product Name | UEB1-70 |
| Product or Component Type | Miniature circuit-breaker |
| Range | UEB1 |
| Rated Current (In) | 5A, 10A, 15A, 20A, 25A, 30A, 35A, 40A, 45A, 50A, 60A |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Rated insulation voltage (Ui) | 690 V AC |
| Rated Voltage | 120 Va.c./ 240Va.c.(1P、2P); 240 Va.c.(2P、3P) |
| REACh Regulation | REACh Declaration |
| Relative humidity | 90%-95% RH(below 40℃) |
| RoHS Exemption Information | Yes |
| Standards | UL489 |
| Sustainable Offer Status | Premium product |
| Tightening torque | 3.5N·m~4.5 N·m |
| Trip Unit Technology | Thermal-magnetic |
| Tropicalisation | / |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Width | 1P:18.8 mm、2P:37.6 mm、3P:56.4 mm |
| Wire connection terminal | BB—Box lug and Box lug; BQ—Box lug and QC terminal |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for UEB1-70. For a missing document or a specific revision, our experts send it to you.
Hongfa UEB1-70 miniature circuit breaker for AC circuit protection with thermal-magnetic tripping, intended for distribution boards. Available in 1P, 2P and 3P versions.
| Parameter | Value |
|---|---|
| Ambient Air Temperature for Operation | -10℃~+60℃ |
| Ambient Air Temperature for Storage | -40℃~+70℃ |
| Breaking Capacity | 10000A |
| China RoHS Regulation | China RoHS declaration; Product out of China RoHS scope. Substance declaration for your information |
| Colour | black |
| Connections - Terminals | 14AWG-4AWG |
| Control type | Toggle |
| Depth | 102mm |
| Device Application | Distribution |
| Device Short Name | / |
| Electrical Durability | 10000 cycles |
| Environmental Disclosure | Product Environmental Profile |
| EU RoHS Directive | Compliant EU RoHS Declaration |
| Height | 79.2mm |
| Local Signalling | Trip indicator |
| Mechanical Durability | 20000 cycles |
| Mercury Free | Yes |
| Mounting Support | DIN rail、Mounting bracket |
| Net weight | 1P:153.0g、、2P: 305.5g 、3P: 457.5g |
| Network Frequency | 50/60Hz |
| Network type | AC |
| Number of Units in Package 2 | 1P:80、2P: 40、3P: 24 |
| Overvoltage category | Ⅱ/Ⅲ |
| Package Height 2 | 216mm |
| Package Length 2 | 414mm |
| Package Weight 2 | 1P:=13.7kg、2P: =13.7kg 、3P: =12.5kg |
| Package Width 2 | 282mm |
| Poles Description | 1P、2P、3P |
| Power-frequency withstand voltage | 2000V/1min |
| Product Name | UEB1-70 |
| Product or Component Type | Miniature circuit-breaker |
| Range | UEB1 |
| Rated Current (In) | 5A, 10A, 15A, 20A, 25A, 30A, 35A, 40A, 45A, 50A, 60A |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Rated insulation voltage (Ui) | 690 V AC |
| Rated Voltage | 120 Va.c./ 240Va.c.(1P、2P); 240 Va.c.(2P、3P) |
| REACh Regulation | REACh Declaration |
| Relative humidity | 90%-95% RH(below 40℃) |
| RoHS Exemption Information | Yes |
| Standards | UL489 |
| Sustainable Offer Status | Premium product |
| Tightening torque | 3.5N·m~4.5 N·m |
| Trip Unit Technology | Thermal-magnetic |
| Tropicalisation | / |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Width | 1P:18.8 mm、2P:37.6 mm、3P:56.4 mm |
| Wire connection terminal | BB—Box lug and Box lug; BQ—Box lug and QC terminal |
Answers to the questions that the recorded characteristics of UEB1-70 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Net weight": 1P:153.0g、、2P: 305.5g 、3P: 457.5g.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Modular miniature circuit breaker 1P/2P/3P rated 5 to 60 A

3KA Curve MCB Housing Mini Circuit Breaker

2 Pole Residual Current Circuit Breaker RCCB


Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | UEB1-70 |
| Manufacturer | Hongfa |
Miniature Circuit Breakers
UL 489 3-pole miniature circuit breaker, type C curve · Ref. : HCB1U-60/3-1
Price on request
Miniature Circuit Breakers
Fixed metal-enclosed medium voltage switchgear · Ref. : XGN66-12
Price on request
Miniature Circuit Breakers
Indoor high-voltage vacuum circuit breaker 40.5 kV · Ref. : WEV-40.5
Price on request
Miniature Circuit Breakers
4-pole AC type residual current circuit breaker 30 mA · Ref. : TORD4-4P
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details