Hytronik HC419VRC HF occupancy sensor with tri-level dimming, built in low-bay luminaires for offices, meeting rooms and classrooms.
Operating Voltage Range120-277 VAC
HF operating frequency (Ghz):5.8Ghz+/-75MHz
Storage temperature max.:70 °C
Storage temperature min.:-40 °C
Maximum Mounting Height:5.0000 m
Mounting heightLow-bay
Product overview
Overview. The Hytronik HC419VRC is a tri-level control HF occupancy sensor suitable for indoor use. It is built into the luminaire and is configured by DIP switches or by infrared remote controller.
Main characteristics. It detects by microwave (MW) at an HF operating frequency of 5.8 GHz ±75 MHz, with a detection angle of 30° to 150° and a detection range (diameter) of 8x5. It includes the tri-level corridor function, daylight harvesting, Human Centric Lighting (HCL) and a warm-up time of 20 s. It is designed for low-bay mounting heights up to 5.0 m and may suit round luminaires up to 6 m high.
Connectivity and synchronisation. Connection is made through a standard 2-cable connector. Up to 10 units can be synchronised together. Configuration is done by DIP switch or infrared (IR) remote controller, the HRC-05 sensor remote controller being listed as a compatible accessory.
Power and environment. It operates on alternating current with an operating voltage range of 120 to 277 VAC. The ambient operating temperature ranges from -20 °C to 60 °C, the storage temperature from -40 °C to 70 °C, and the permissible humidity from 10 % to 90 %. Its IP rating is IP20, for indoor use only.
Dimensions. The product measures 102 mm long, 45 mm wide and 28 mm high, for a weight of 70 g.
Typical uses. Offices, meeting rooms and classrooms, where the sensor controls lighting according to occupancy and daylight.
Hytronik HC419VRC HF occupancy sensor with tri-level dimming, built in low-bay luminaires for offices, meeting rooms and classrooms.
Operating Voltage Range120-277 VAC
HF operating frequency (Ghz):5.8Ghz+/-75MHz
Storage temperature max.:70 °C
Storage temperature min.:-40 °C
Maximum Mounting Height:5.0000 m
2. Datasheet extract (recorded values)
Parameter
Value
Ambient temperature max.:
60 °C
Ambient temperature min.:
-20 °C
Commissioning Methods:
IR Remote Controller
Compact
Super compact size - Tri-level dimming sensor
Connector Type
Standard 2 cables
Daylight Harvest:
Yes
Detection Angle
30° - 150°
Detection Methods:
Microwave (MW)
Detection range (Diameter):
8x5
Features
Tri-level (Corridor Function)
Flexibale
Synchronization Contro in maximum 10pcs
HF operating frequency (Ghz):
5.8Ghz+/-75MHz
Human Centric Lightning (HCL):
Yes
Humidity max:
90 %
Humidity min:
10 %
Installation Type
Built-in
IP Rate
IP20
Maximum Mounting Height:
5.0000 m
Mounting height
Low-bay
Mounting Hole
4.2000 mm
Operating Voltage Range
120-277 VAC
Product Height
28.0000 mm
Product Length
102.0000 mm
Product Weight
70.0000 g
Product Width
45.0000 mm
Simple
Daylight, detection range and holdtime configuration via Dip-Switch/ IR controller
Storage temperature max.:
70 °C
Storage temperature min.:
-40 °C
Tri-level (Corridor function):
Yes
Voltage Type:
AC
Warming-up:
20 s
Zhaga:
No
Applications and use cases
Architectures in which HC419VRC can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Meeting rooms are booked but empty, and some areas are always full. Presence sensors, radars and counting cameras measure how spaces are really used, room by room or at entrances
To check
Presence per room or counting at entrances, or both
Privacy requirements, which favour radar or anonymous counting
Hotel rooms keep heating, cooling and lights on while empty. A room control system links thermostats, switches, door contacts and lighting controllers so the room adapts to the guest’s presence
To check
Wired bus or wireless system, depending on renovation or new build
Link with the property management system for check-in and check-out
Behaviour when the guest is absent (setback temperature, lights off)
Associated system blocks
Climate controlSwitches and panelsPresence detectionLighting control
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for HC419VRC and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productHytronik
HC419VRC
Tri-level HF occupancy sensor for low-bay luminaires
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details