Compact DALI lighting control unit with built-in DALI power supply, designed to manage lighting linked to microwave or PIR sensor heads.
Operating Voltage Range220-240 VAC 50/60 Hz
Dimming (Output) Interface:DALI
Storage temperature max.:70 °C
Storage temperature min.:-40 °C
Mounting Hole4.5000 mm
AdaptableSmall control unit with strain relief
Product overview
HCD038/P DALI lighting control unit from Hytronik — The HCD038/P is a DALI lighting control unit with built-in DALI power supply, designed to drive a master luminaire associated with various microwave (MW) and passive infrared (PIR) sensor heads.
Main characteristics. Small control unit with strain relief, built-in installation, IP20 protection rating. Daylight Harvest and Tri-level (corridor function) features, and two push inputs for flexible manual control.
Interfaces and connectivity. DALI dimming output. Standard 2-cable connector. Compatible with many DALI sensor heads. The compatible heads listed by the manufacturer include Bluetooth, PIR and HF models connected through an RJ12 connector.
Power and environment. Operating voltage 220-240 VAC, 50/60 Hz. Ambient temperature from -20 °C to 55 °C, storage temperature from -40 °C to 70 °C, humidity from 10 % to 90 %. Warm-up time of 20 s. Dimensions 120 x 30 x 21 mm, weight 50 g.
Typical uses. Master luminaire with sensor, classrooms and offices, as indicated by the manufacturer.
Compact DALI lighting control unit with built-in DALI power supply, designed to manage lighting linked to microwave or PIR sensor heads.
Operating Voltage Range220-240 VAC 50/60 Hz
Dimming (Output) Interface:DALI
Storage temperature max.:70 °C
Storage temperature min.:-40 °C
Mounting Hole4.5000 mm
2. Datasheet extract (recorded values)
Parameter
Value
Adaptable
Small control unit with strain relief
Ambient temperature max.:
55 °C
Ambient temperature min.:
-20 °C
Connector Type
Standard 2 cables
Detection Methods:
Microwave (MW), Passive Infrared (PIR)
Dimming (Output) Interface:
DALI
Features
Daylight Harvest, Tri-level (Corridor Function)
Flexible
2 Push inputs for fiexible manual control
Human Centric Lightning (HCL):
No
Humidity max:
90 %
Humidity min:
10 %
Installation Type
Built-in
IP Rate
IP20
Mounting Hole
4.5000 mm
Operating Voltage Range
220-240 VAC 50/60 Hz
Product Height
21.0000 mm
Product Length
120.0000 mm
Product Status:
Active / New
Product Weight
50.0000 g
Product Width
30.0000 mm
Storage temperature max.:
70 °C
Storage temperature min.:
-40 °C
Tri-level (Corridor function):
Yes
Versatile
Many sensor options for DALI control
Voltage Type:
AC
Warming-up:
20 s
Zhaga:
No
Applications and use cases
Architectures in which HCD038/P can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Hotel rooms keep heating, cooling and lights on while empty. A room control system links thermostats, switches, door contacts and lighting controllers so the room adapts to the guest’s presence
To check
Wired bus or wireless system, depending on renovation or new build
Link with the property management system for check-in and check-out
Behaviour when the guest is absent (setback temperature, lights off)
Associated system blocks
Climate controlSwitches and panelsPresence detectionLighting control
Street lights burn at full power all night. Lighting controllers on each luminaire, linked by LoRaWAN, dim, switch and report each light from a central platform
To check
Socket type on the luminaires (NEMA or Zhaga)
Dimming interface of the drivers
Gateway coverage across the network of streets
Associated system blocks
Luminaire controllersGateway
Need a complete solution?
Send a request for HCD038/P and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productHytronik
HCD038/P
Integrated DALI lighting control unit with DALI power supply
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details