Hytronik passive infrared (PIR) occupancy sensor head for high-bay luminaires, compatible with photocell daylight harvesting. Available on quotation from Atlas Electronics.
Operating Voltage Range5 VDC
Storage temperature max.:70 °C
Storage temperature min.:-40 °C
Maximum Mounting Height:15.0000 m
Mounting heightMid & High-bay
Ambient temperature max.:55 °C
Product overview
Hytronik HIR09/C. PIR occupancy sensor head for high-bay luminaires. The HIR09/C is a PIR sensor head compatible with daylight harvesting, designed to work with linear control bases such as the HCD038V and HCD038/P.
Main characteristics. Passive infrared detection with a 360° detection angle and a detection range of 24x15 diameter. Maximum mounting height of 15.0 m, suited to mid and high-bay mounting. Commissioning with an IR remote controller using one-key setup, with a 20 s warm-up time. Compact standard rectangular Plug&Play design measuring 63.0 x 40.5 x 33.9 mm for 38.0 g.
Interfaces and connectivity. RJ12 connector to the control body, M 13x1.5 mm conduit thread, and built-in installation with conduit screws or Plug & Play sensor heads.
Power and environment. 5 VDC operating voltage. Ambient temperature from -20 °C to 55 °C, storage temperature from -40 °C to 70 °C, humidity from 10 % to 90 %. IP20 rating, intended for indoor use.
Typical uses. Offices and classrooms, where occupancy detection combined with daylight harvesting controls lighting according to occupancy and ambient light level.
Integration. Extensive Plug&Play feature options to adapt the sensor to the luminaire design. The HIR09/C does not include the Tri-level (corridor) function nor Human Centric Lighting. Available on quotation from Atlas Electronics.
Hytronik passive infrared (PIR) occupancy sensor head for high-bay luminaires, compatible with photocell daylight harvesting. Available on quotation from Atlas Electronics.
Operating Voltage Range5 VDC
Storage temperature max.:70 °C
Storage temperature min.:-40 °C
Maximum Mounting Height:15.0000 m
Mounting heightMid & High-bay
2. Datasheet extract (recorded values)
Parameter
Value
Ambient temperature max.:
55 °C
Ambient temperature min.:
-20 °C
Commissioning Methods:
IR Remote Controller
Compact
Standard rectangular Plug&Play sensor design
Conduit thread
M 13x1.5mm
Connector Type
RJ12
Daylight Harvest:
Yes
Detection Angle
360°
Detection Methods:
Passive Infrared (PIR)
Detection range (Diameter):
24x15
Features
Daylight Harvest
Human Centric Lightning (HCL):
No
Humidity max:
90 %
Humidity min:
10 %
Installation Type
Built-in, Conduit screws, Plug & Play Sensor Heads
IP Rate
IP20
Maximum Mounting Height:
15.0000 m
Mounting height
Mid & High-bay
Operating Voltage Range
5 VDC
Product Height
33.9000 mm
Product Length
63.0000 mm
Product Weight
38.0000 g
Product Width
40.5000 mm
Simple
Daylight harvest with Photocell
Storage temperature max.:
70 °C
Storage temperature min.:
-40 °C
Tri-level (Corridor function):
No
User-Friendly
With one-key commissioning with IR controller
Voltage Type:
DC
Warming-up:
20 s
Applications and use cases
Architectures in which HIR09/C can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Meeting rooms are booked but empty, and some areas are always full. Presence sensors, radars and counting cameras measure how spaces are really used, room by room or at entrances
To check
Presence per room or counting at entrances, or both
Privacy requirements, which favour radar or anonymous counting
Hotel rooms keep heating, cooling and lights on while empty. A room control system links thermostats, switches, door contacts and lighting controllers so the room adapts to the guest’s presence
To check
Wired bus or wireless system, depending on renovation or new build
Link with the property management system for check-in and check-out
Behaviour when the guest is absent (setback temperature, lights off)
Associated system blocks
Climate controlSwitches and panelsPresence detectionLighting control
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for HIR09/C and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productHytronik
HIR09/C
PIR occupancy sensor head for high-bay luminaires with photocell
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details